Table 1
Diagnostic Codes Table
CDL Code J1939 Code Code Description
(code descriptions may vary) Comments
291-5 4212-5 Engine Cooling Fan Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
291-6 4212-6 Engine Cooling Fan Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine fan control solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
1076-5 Engine Cooling Fan Bypass Solenoid : Current Below Normal The Electronic Control Module (ECM) detects an open circuit in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan control solenoid. The code is logged.
1076-6 Engine Cooling Fan Bypass Solenoid : Current Above Normal The ECM detects a short circuit to ground in the circuit for the engine cooling fan bypass solenoid.
The ECM sends minimum current to the fan bypass solenoid. The code is logged. The ECM monitors engine coolant temperature, intake manifold air temperature, and hydraulic oil temperature. The ECM monitors the sensors in order to determine the correct speed for the engine cooling fan.The ECM controls the speed of the fan by controlling the current to the engine fan control solenoid. The engine fan control solenoid controls the amount of pressure to the fan pump by allowing oil to bypass the fan pump. The fan pump drives the fan. When the ECM outputs minimum current to the engine fan control solenoid, less oil is bypassed. The fan pump will now drive the fan at a higher rpm. When the ECM outputs maximum current to the engine fan control solenoid, more oil is bypassed. The fan pump will now drive the fan at a lower rpm.If the ECM detects a system fault, the ECM provides minimum current to the solenoid. Minimum current ensures a maximum fan speed while the fault condition exists.An override is available with Caterpillar Electronic Technician (ET). An override allows the fan to be manually changed from the minimum to the maximum rpm.
Illustration 1 g03011017
Table 2
Troubleshooting Test Steps Values Results
1. Check for Active Diagnostic Codes
A. Remove the electrical power from the ECM.
B. Verify that the solenoid connector is free of debris and connected securely.
C. Connect Cat ET to the service tool connector.
D. Restore the electrical power to the ECM.
E. Select diagnostic tests from Cat ET.
F.Select the "Override Parameters" screen on Cat ET.
G. Activate the fan override.
H. Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes.
Wait at least 30 seconds in order for the diagnostic code to become active.
I. Disable the fan override.
Active Diagnostic codes
Result: No diagnostic codes are active.
The problem may have been related to a faulty connection in the harness. Carefully inspect the connectors and wiring. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Result: A short circuit diagnostic code (-6) is active at this time.
Proceed to Test Step
Caterpillar SIS machinery equipment:
Parts tool Caterpillar catalog:
3570051
TOOL GP
901C, 902C, 903C
901C, 902C, 903C
4339654
TOOL-SPADE
H35E S
H35E S
4339652
TOOL-SPADE
H35E S
H35E S
4238329
TOOL-MOIL POINT
H35E S
H35E S
4238308
TOOL-MOIL POINT
H35E S
H35E S
4288033
TOOL-CHISEL
H35E S
H35E S
4F6783
TOOL GROUP
D315
D315
6H9903
TOOL GROUP
D315
D315
8H3073
TOOL GROUP
D375D
D375D
6H9899
TOOL GROUP
D375D
D375D
8F1369
TOOL GROUP
D337
D337
6F7861
TOOL GROUP
D364
D364