Removal Procedure
Note: Cleanliness is an important factor. Before you begin the removal procedure, the exterior of the components should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.Note: Put identification marks on all lines, on all hoses, on all harness assemblies, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01336903
Disconnect hose assemblies (3) .
Loosen bolts (1) and remove refrigerant receiver-dryer (2) .Installation Procedure
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
Illustration 2 g01336903
Position refrigerant receiver-dryer (2) and tighten bolts (1) .
Connect hose assemblies (3) .
Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Note: Cleanliness is an important factor. Before you begin the removal procedure, the exterior of the components should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.Note: Put identification marks on all lines, on all hoses, on all harness assemblies, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g01336903
Disconnect hose assemblies (3) .
Loosen bolts (1) and remove refrigerant receiver-dryer (2) .Installation Procedure
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
Illustration 2 g01336903
Position refrigerant receiver-dryer (2) and tighten bolts (1) .
Connect hose assemblies (3) .
Charge the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Parts tool Caterpillar catalog:
5331149
TOOL-INSTALLER
Caterpillar
Caterpillar
5331148
TOOL GP
Caterpillar
Caterpillar
5331147
TOOL GP
Caterpillar
Caterpillar
5331146
TOOL GP
Caterpillar
Caterpillar
5331145
TOOL-BODY
Caterpillar
Caterpillar
5331144
TOOL-BODY
Caterpillar
Caterpillar
5331183
TOOL AS
Caterpillar
Caterpillar
5331166
TOOL
Caterpillar
Caterpillar
5331163
TOOL GP
Caterpillar
Caterpillar
5331160
TOOL GP
Caterpillar
Caterpillar
5331158
TOOL-INSERTION
Caterpillar
Caterpillar
5331157
TOOL GP
Caterpillar
Caterpillar