2419022 TORQUE CONVERTER & HOUSING GP Caterpillar parts
950H, 962H, IT62H
Rating:
Alternative (cross code) number:
CA2419022
241-9022
2419022
CA2419022
241-9022
2419022
INTEGRATED TOOLCARRIER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$99.99
17 May 2022
Amazon.com
PantsSaver Custom Fits Car Floor Mats for MAZDA TRIBUTE 2002,Front & 2nd Seat Heavy Duty Floor Mats (4PC), All Weather Protection for Vehicle,Grey
PantsSaver Custom designed to fit your MAZDA TRIBUTE 2002 , Install in seconds, no cutting or tools required || Features a patented Pants Saver central pan that holds and traps up to 500ml (16-Ounce) of water and keeps you and your vehicle's interior clean and dry || Superior All weather performance, Made from non-toxic, wear-resistant recycled PVC, BPA-free PantsSaver xact fit floor mats are waterproof and odorless even in extreme weather and maintain flexibility and durability down to minus 76°F (-60°C)
PantsSaver Custom designed to fit your MAZDA TRIBUTE 2002 , Install in seconds, no cutting or tools required || Features a patented Pants Saver central pan that holds and traps up to 500ml (16-Ounce) of water and keeps you and your vehicle's interior clean and dry || Superior All weather performance, Made from non-toxic, wear-resistant recycled PVC, BPA-free PantsSaver xact fit floor mats are waterproof and odorless even in extreme weather and maintain flexibility and durability down to minus 76°F (-60°C)
Compatible equipment models: 2419022:
Information:
Cooling System
Change Coolant
Do not change the coolant until you read and understand the material in the "Cooling System Specifications" section.
Typical Example1. Remove the radiator filler cap slowly to relieve pressure. 2. Remove the drain plug on bottom of water pump housing. 3. Remove the two block drain plugs from both sides of the engine. Allow coolant to drain.4. Clean and install all drain plugs.5. Fill the cooling system with a cleaning solution. Use a commercially available cleaner or 1 kg (2 lbs) sodium bisulfate per 38 liters (10 gal) water as a cleaner.6. Start and operate the engine for 1/2 hour.7. Stop the engine and drain the cleaning solution.8. Flush the system with water with the engine stopped, until the draining water is clear. 9. Close the drain plugs. Fill the system with a neutralizer. Use a commercially available neutralizer.10. Operate the engine for ten minutes.11. Stop the engine and drain the neutralizer.12. Flush the system with water with the engine stopped, until the draining water is clear.13. Close the drain plugs.14. Fill the system with clean water and operate the engine for five minutes.15. Stop the engine. Drain the cooling system and close the drain plugs.16. Repeat the flushing procedure until the draining water is clear.17. Add the coolant solution. See "Refill Capacities."Also add .95 liters (1 quart) of coolant system conditioner, when not using Caterpillar Antifreeze.18. Start the engine and operate it with the radiator cap off, until the thermostat opens and the level stabilizes.19. Maintain the coolant level about 13 mm (1/2 inch) below the bottom of the fill tube.20. Install the radiator cap and access cover.21. Stop the engine.
Change Coolant
Do not change the coolant until you read and understand the material in the "Cooling System Specifications" section.
Typical Example1. Remove the radiator filler cap slowly to relieve pressure. 2. Remove the drain plug on bottom of water pump housing. 3. Remove the two block drain plugs from both sides of the engine. Allow coolant to drain.4. Clean and install all drain plugs.5. Fill the cooling system with a cleaning solution. Use a commercially available cleaner or 1 kg (2 lbs) sodium bisulfate per 38 liters (10 gal) water as a cleaner.6. Start and operate the engine for 1/2 hour.7. Stop the engine and drain the cleaning solution.8. Flush the system with water with the engine stopped, until the draining water is clear. 9. Close the drain plugs. Fill the system with a neutralizer. Use a commercially available neutralizer.10. Operate the engine for ten minutes.11. Stop the engine and drain the neutralizer.12. Flush the system with water with the engine stopped, until the draining water is clear.13. Close the drain plugs.14. Fill the system with clean water and operate the engine for five minutes.15. Stop the engine. Drain the cooling system and close the drain plugs.16. Repeat the flushing procedure until the draining water is clear.17. Add the coolant solution. See "Refill Capacities."Also add .95 liters (1 quart) of coolant system conditioner, when not using Caterpillar Antifreeze.18. Start the engine and operate it with the radiator cap off, until the thermostat opens and the level stabilizes.19. Maintain the coolant level about 13 mm (1/2 inch) below the bottom of the fill tube.20. Install the radiator cap and access cover.21. Stop the engine.
Caterpillar SIS machinery equipment:
Caterpillar SIS
950H Wheel Loader N1A00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
962H Wheel Loader N4A00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H Wheel Loader K5K00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H Wheel Loader K5K00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
962H Wheel Loader K6K00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
962H Wheel Loader K6K00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H Wheel Loader M1G00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
IT62H Integrated Toolcarrier M5G00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
962H Wheel Loader M3G00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H PhII Wheel Loader K5K01000-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H PhII Wheel Loader K5K01000-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H Wheel Loader JAD00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
962H Wheel Loader MAL00001-UP (MACHINE) POWERED BY C7 Engine »
241-9022
TORQUE CONVERTER & HOUSING GP
950H WHEEL LOADER J5J00001-UP (MACHINE) POWERED BY C7 ENGINE »
241-9022
TORQUE CONVERTER GROUP
962H WHEEL LOADER J6J00001-UP (MACHINE) POWERED BY C7 ENGINE »
241-9022
TORQUE CONVERTER GROUP
950H WHEEL LOADER J5J01501-UP (MACHINE) POWERED BY C7 ENGINE »
241-9022
TORQUE CONVERTER GP
962H WHEEL LOADER J6J00501-UP (MACHINE) POWERED BY C7 ENGINE »
241-9022
TORQUE CONVERTER GP
Caterpillar parts catalog:
Parts torque Caterpillar catalog:
1163825
TORQUE CONVERTER GP
950G, 950G II, 950H, 962G, 962G II, 962H, IT62G, R1300G II
950G, 950G II, 950H, 962G, 962G II, 962H, IT62G, R1300G II
1685223
TORQUE CONVERTER GP
950G II, 950H, 962G II, 962H, IT62G II, IT62H
950G II, 950H, 962G II, 962H, IT62G II, IT62H
2686472
TORQUE CONVERTER & HOUSING GP
950H, 962H
950H, 962H
3T4029
TORQUE CONVERTER GP
D6H, D6H XL, D6H XR
D6H, D6H XL, D6H XR
1T2076
TORQUE CONVERTER GP
583R, D8R
583R, D8R
1T1936
TORQUE CONVERTER GP
924F, IT18F, IT24F
924F, IT18F, IT24F
3P4544
TORQUE CONVERTER/DIVIDER
583K, D8K
583K, D8K
1P6474
TORQUE CONTROL
561C, D5, D6C
561C, D5, D6C
1807973
TORQUE CONVERTER GP
AD45B, AD55
AD45B, AD55
9P4889
TORQUE CONVERTER GP
589, D8L, D9N
589, D8L, D9N
2Y9505
TORQUE CONVERTER GP
D6D, D6E
D6D, D6E