1M3826 TRACK ROLLER GROUP Caterpillar parts
561C, 955C, 955H, 977D, D5
Rating:
Alternative (cross code) number:
CA1M3826
1M-3826
1M3826
CA1M3826
1M-3826
1M3826
Weight: 64 pounds 29 kg.
PIPELAYER, TRACK-TYPE TRACTOR,
Compatible equipment models: 1M3826:
Information:
Which Generate This Code:
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
K1     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0480 FMI 03 is an open circuit of the "K4" relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0480 FMI 03 is active.Note: The "DIAG" indicator will be flashing and the CID 0480 FMI 03 will be present on the display if the diagnostic code is active.Expected Result:A CID 0480 FMI 03 is displayed as an active diagnostic code or the diagnostic code
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
K1     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0480 FMI 03 is an open circuit of the "K4" relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0480 FMI 03 is active.Note: The "DIAG" indicator will be flashing and the CID 0480 FMI 03 will be present on the display if the diagnostic code is active.Expected Result:A CID 0480 FMI 03 is displayed as an active diagnostic code or the diagnostic code
Caterpillar SIS machinery equipment:
Caterpillar SIS
955 TRAXCAVATOR 12A00001-08418 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
977 TRAXCAVATOR 20A00001-04222 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
955 TRAXCAVATOR 60A00001-04999 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
955 TRAXCAVATOR 60A05000-08412 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
561C PIPELAYER 92J00001-00390 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
561C PIPELAYER 92J00001-00390 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
D5 TRACTOR / POWER SHIFT / 95J00001-00356 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
D5 TRACTOR / POWER SHIFT / 95J00001-00356 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
D5 TRACTOR / DIRECT DRIVE / 93J00001-00731 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
D5 TRACTOR - SPECIAL APPLICATION 98J00001-01133 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
D5 TRACTOR - SPECIAL APPLICATION 98J00001-01133 (MACHINE) »
1M-3826
TRACK ROLLER GROUP
Caterpillar parts catalog:
Parts track Caterpillar catalog:
1M4576
TRACK GROUP
977D
977D
1M1593
TRACK GROUP
977D
977D
1M1589
TRACK GROUP
977D
977D
3K7935
TRACK GROUP
955H
955H
3857745
TRACK GP
D6T LGP, D6T XL
D6T LGP, D6T XL
2474665
TRACK GP
330D L, 345C, 345C L
330D L, 345C, 345C L
2394389
TRACK ADJUSTER & RECOIL GP
315D L, 318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 L, 323E L
315D L, 318E L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D GC, 320D L, 320D LN, 320D LRR, 320D RR, 320D2, 320D2 L, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 321D LCR, 323D L, 323D LN, 323D2 L, 323E L
3111926
TRACK GP
345C, 345C L, 345D L, 345D L VG, 349D, 349D L, 349E L, 349E L VG, 349F L
345C, 345C L, 345D L, 345D L VG, 349D, 349D L, 349E L, 349E L VG, 349F L
3855456
TRACK GP
D6T LGP, D6T XL
D6T LGP, D6T XL
2349671
TRACK GP
D6R II, D6R III, D6T
D6R II, D6R III, D6T
8E8645
TRACK GP
235C, 235D
235C, 235D
3857756
TRACK AR
D6T LGP, D6T XL
D6T LGP, D6T XL
7P4002
TRACK GP
973
973
3852677
TRACK GP
D6T LGP, D6T XL
D6T LGP, D6T XL
3499552
TRACK AR
312D, 336D
312D, 336D