3105680 TRACK AR Caterpillar parts
D3K XL
Rating:
Alternative (cross code) number:
CA3105680
310-5680
3105680
CA3105680
310-5680
3105680
TRACK-TYPE TRACTOR,
Compatible equipment models: 3105680:
Information:
The values in Table 12 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 12
Rated Voltage 24 VDC
Coil Resistance 32.0 3.2Ω (T=20° C) The On/Off solenoids include:
Swing brake solenoid
Travel speed solenoid
Straight travel solenoid
Hydraulic lock solenoid
Swing priority solenoidProportional Reducing Solenoid Valve
Illustration 22 g02703776The values in Table 13 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 13
Current Range 0 mA ~ 700 mA
Coil Resistance 11.5 0.5Ω (T=20° C)
Illustration 23 g02263554
A - Port pressure (kPa) vs Current (mA)
The proportional reducing solenoid valve is used on machines equipped with tool control. The P-Port is blocked and does not allow pressure to the A-port. Therefore, the machine ECM must apply current to the PRV to sent pressure to the A-port of the PRV.Reverse Proportional Reducing Solenoid Valve
Illustration 24 g02304374
Valve cutaway, hydraulic schematic symbol, and electrical connector designation
The values in Table 14 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 14
Current Range 0 mA ~ 700 mA
Coil Resistance 11.5 0.5Ω (T=20° C)
Illustration 25 g02304414Reverse PRV's have the P-port open to the A-port with no current applied. Therefore, the machine ECM applies current to the PRV to decrease the pressure at the A-port.The reverse PRV's include:
Boom Regeneration PRVESP Pump Solenoid Valve
Illustration 26 g03236478The values in Table 15 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 15
Rated Voltage 24 V
Coil Resistance 5 0.3Ω (T=25° C) The ESP pump solenoid valve is on the drive pump and idler pump regulators. The solenoid valve controls the horsepower control spool in the pump regulator. Current of 1 amp maintains the spool in the neutral position and cannot be adjusted.Data Link
Cat Data Link
Illustration 27 g02694217
Schematic of the “Cat Data Link” Circuit
The Cat Data Link is an input and an output of the Machine ECM. The Cat Data Link connects to the Machine ECM at connector contact J2-16 and J2-25. The data link is designed to carry communications between the controller and the monitor. The data link is not a visible component. The data link consists of internal control circuits and a harness wiring. The data link is bidirectional. The controller can receive information and the controller can send information through the data link. The controller sends information about the fuel level, temperature of the engine coolant, and many other signals to the monitor panel.CAN Data Link
Illustration 28 g02694576
Schematic of the "CAN Data Link" Circuit
The CAN data link is used for communication between the following modules: Machine ECM, Switch Panel and Monitor. Two 120 Ohm terminating resistors must be installed in the wiring harness in order for the CAN data link to function properly.Action Alarm
The action alarm SOUNDS to alert the operator when a high emergency condition is present. For example, the engine oil pressure decreases below a set value.Travel Alarm
The travel alarm SOUNDS to alert the area that the machine is moving.
Table 12
Rated Voltage 24 VDC
Coil Resistance 32.0 3.2Ω (T=20° C) The On/Off solenoids include:
Swing brake solenoid
Travel speed solenoid
Straight travel solenoid
Hydraulic lock solenoid
Swing priority solenoidProportional Reducing Solenoid Valve
Illustration 22 g02703776The values in Table 13 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 13
Current Range 0 mA ~ 700 mA
Coil Resistance 11.5 0.5Ω (T=20° C)
Illustration 23 g02263554
A - Port pressure (kPa) vs Current (mA)
The proportional reducing solenoid valve is used on machines equipped with tool control. The P-Port is blocked and does not allow pressure to the A-port. Therefore, the machine ECM must apply current to the PRV to sent pressure to the A-port of the PRV.Reverse Proportional Reducing Solenoid Valve
Illustration 24 g02304374
Valve cutaway, hydraulic schematic symbol, and electrical connector designation
The values in Table 14 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 14
Current Range 0 mA ~ 700 mA
Coil Resistance 11.5 0.5Ω (T=20° C)
Illustration 25 g02304414Reverse PRV's have the P-port open to the A-port with no current applied. Therefore, the machine ECM applies current to the PRV to decrease the pressure at the A-port.The reverse PRV's include:
Boom Regeneration PRVESP Pump Solenoid Valve
Illustration 26 g03236478The values in Table 15 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 15
Rated Voltage 24 V
Coil Resistance 5 0.3Ω (T=25° C) The ESP pump solenoid valve is on the drive pump and idler pump regulators. The solenoid valve controls the horsepower control spool in the pump regulator. Current of 1 amp maintains the spool in the neutral position and cannot be adjusted.Data Link
Cat Data Link
Illustration 27 g02694217
Schematic of the “Cat Data Link” Circuit
The Cat Data Link is an input and an output of the Machine ECM. The Cat Data Link connects to the Machine ECM at connector contact J2-16 and J2-25. The data link is designed to carry communications between the controller and the monitor. The data link is not a visible component. The data link consists of internal control circuits and a harness wiring. The data link is bidirectional. The controller can receive information and the controller can send information through the data link. The controller sends information about the fuel level, temperature of the engine coolant, and many other signals to the monitor panel.CAN Data Link
Illustration 28 g02694576
Schematic of the "CAN Data Link" Circuit
The CAN data link is used for communication between the following modules: Machine ECM, Switch Panel and Monitor. Two 120 Ohm terminating resistors must be installed in the wiring harness in order for the CAN data link to function properly.Action Alarm
The action alarm SOUNDS to alert the operator when a high emergency condition is present. For example, the engine oil pressure decreases below a set value.Travel Alarm
The travel alarm SOUNDS to alert the area that the machine is moving.
Caterpillar SIS machinery equipment:
Parts track Caterpillar catalog:
1806166
TRACK GP
D3K XL, D4G
D3K XL, D4G
1987392
TRACK GP
D3K XL, D4G
D3K XL, D4G
1987393
TRACK GP
D3K XL, D4G
D3K XL, D4G
2864303
TRACK AR
D3K XL
D3K XL
2864308
TRACK AR
D3K XL
D3K XL
2864311
TRACK AR
D3K XL
D3K XL
2864313
TRACK AR
D3K XL
D3K XL
2864318
TRACK AR
D3K XL
D3K XL
2893063
TRACK GP
D3K XL
D3K XL
2893064
TRACK GP
D3K XL
D3K XL
2893071
TRACK GP
D3K XL
D3K XL
3107249
TRACK GP
D3K XL
D3K XL
2864318
TRACK AR
D3K XL
D3K XL
2864313
TRACK AR
D3K XL
D3K XL
2864311
TRACK AR
D3K XL
D3K XL
2864308
TRACK AR
D3K XL
D3K XL
2864303
TRACK AR
D3K XL
D3K XL
2864301
TRACK AR
D3K XL
D3K XL
2864309
TRACK AR
D3K2 LGP, D4K XL, D4K2 XL
D3K2 LGP, D4K XL, D4K2 XL
2864304
TRACK AR
D4K XL, D4K2 XL
D4K XL, D4K2 XL
3107249
TRACK GP
D3K XL
D3K XL
2893071
TRACK GP
D3K XL
D3K XL
2893064
TRACK GP
D3K XL
D3K XL
2893063
TRACK GP
D3K XL
D3K XL