Information:
Illustration 1 g02034460
Schematic of the "Attachment Stem 2 Extend Pressure" SolenoidThis diagnostic code is associated with the "Attachment Stem 2 Extend Pressure" Solenoid. The FMI 03 diagnostic code means that the Machine ECM has determined that the voltage is above normal.The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The energizer circuit of the solenoid for the modulating valve is shorted to the +battery circuit.
The Machine ECM has failed. This situation is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1594 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the Machine ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-4 (wire K857-WH) to all contacts that are used in the machine harness connectors for the Machine ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-4 (K857-WH) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1594 FMI 03 diagnostic code is active.Expected Result:The CID 1594 FMI 03 diagnostic code is active.Results:
YES - The CID 1594 FMI 03 diagnostic code is active. The problem has not been corrected. The ECM may have failed.Repair: A failure of the Machine ECM is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the Machine ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1594 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors. Resume normal machine operation.STOP
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts track Caterpillar catalog:
4155666
TRACK AR
953D
953D
3003661
TRACK GP
953C, 953D
953C, 953D
2444535
TRACK GP
953C, 953D
953C, 953D
2307274
TRACK GP
953C, 953D
953C, 953D
3003662
TRACK GP
953C, 953D
953C, 953D
4155669
TRACK AR
953D
953D
4155670
TRACK AR
953D
953D
4155683
TRACK AR
953D
953D
4155685
TRACK AR
953D
953D
4155686
TRACK AR
953D
953D
4155686
TRACK AR
953D
953D
4155685
TRACK AR
953D
953D
4155683
TRACK AR
953D
953D
4155670
TRACK AR
953D
953D
4155669
TRACK AR
953D
953D
3280758
TRACK GP
D6R III, D6T
D6R III, D6T
4155690
TRACK AR
963D
963D
4155687
TRACK AR
963D
963D
4155673
TRACK AR
963D
963D
4155672
TRACK AR
963D
963D
3643064
TRACK GP
953D
953D