Load Connections – Generator Set Output
For units equipped with T– frame breaker: Installer shall connect conductors in accordance with separate T-frame breaker terminal instruction provided with unit. All conductors shall be sized based upon the 75° C (167° F) ampacities within Table 310-16 of the National Electrical Code, ANSI/NFPA 70, of no less than 100 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater. For units equipped with either R-frame breaker or bus bar (terminal strip) connections: Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring terminal shall be sized for the connection of a conductor having an ampacity based on the 75° C (167° F) column of Table 310-16 of the National Electrical Code, ANSI/NFPA 70, of no less than 100 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater.Equipment Ground Connection
Illustration 1 g03368914Unit ground bar shall be connected in accordance with National Electrical Code, ANSI/NFPA 70, Article 250. Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring ground terminal shall be sized for the connection based on the minimum ground conductor size required by UL as shown in the corresponding column of Table 1.Over-current protection devices
For units without installed circuit breaker over-current protection option, installer shall use off package mounted UL Listed circuit breaker within 7.6 m (25 feet) of generator set.
Table 1
Minimum Ground Conductor Size
AWG or kcmil (mm2)
(Amps) Copper Aluminum or copper-clad aluminum
400 1/0 (53.5) 3/0 (85.0)
500 2/0 (67.4) 4/0 (107.2)
600 2/0 (67.4) 4/0 (107.2)
800 3/0 (85.0) 250 (127)
1000 3/0 (85.0) 250 (127)
1200 3/0 (85.0) 250 (127)
1600 3/0 (85.0) 250 (127)
2000 3/0 (85.0) 250 (127)
2500 3/0 (85.0) 250 (127) Field Wiring – EMCP Controller Interface
Installer shall use Class 1 wiring methods for all controller (customer) connections with following exception. Class 2 wiring methods shall be allowed for Class 2 controller interface wiring when Class 2 conductors are shielded with UL Listed/recognized insulation sleeve or conduit rated to 600V for each individual circuit.Batteries
Servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.When replacing batteries, use the same number and the following type batteries:Cat Premium High Output (PHO) Batteries
Standard battery (wet) BCI Group 31, Calcium Lead Alloy Grid Design, 1000 CCA,Oversize battery (wet) BCI Group 4D, Calcium Lead Alloy Grid Design, 1400 CCA,Standard battery (dry) BCI Group 31, Calcium Lead Alloy Grid Design, 950 CCA,Oversize battery (dry) BCI Group 4D, Low Maintenance, Hybrid Construction, 1300 CCA,
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or
For units equipped with T– frame breaker: Installer shall connect conductors in accordance with separate T-frame breaker terminal instruction provided with unit. All conductors shall be sized based upon the 75° C (167° F) ampacities within Table 310-16 of the National Electrical Code, ANSI/NFPA 70, of no less than 100 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater. For units equipped with either R-frame breaker or bus bar (terminal strip) connections: Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring terminal shall be sized for the connection of a conductor having an ampacity based on the 75° C (167° F) column of Table 310-16 of the National Electrical Code, ANSI/NFPA 70, of no less than 100 percent of the maximum current that the circuit carries during rated conditions. All conductors shall be rated 90° C (194° F) or greater.Equipment Ground Connection
Illustration 1 g03368914Unit ground bar shall be connected in accordance with National Electrical Code, ANSI/NFPA 70, Article 250. Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring ground terminal shall be sized for the connection based on the minimum ground conductor size required by UL as shown in the corresponding column of Table 1.Over-current protection devices
For units without installed circuit breaker over-current protection option, installer shall use off package mounted UL Listed circuit breaker within 7.6 m (25 feet) of generator set.
Table 1
Minimum Ground Conductor Size
AWG or kcmil (mm2)
(Amps) Copper Aluminum or copper-clad aluminum
400 1/0 (53.5) 3/0 (85.0)
500 2/0 (67.4) 4/0 (107.2)
600 2/0 (67.4) 4/0 (107.2)
800 3/0 (85.0) 250 (127)
1000 3/0 (85.0) 250 (127)
1200 3/0 (85.0) 250 (127)
1600 3/0 (85.0) 250 (127)
2000 3/0 (85.0) 250 (127)
2500 3/0 (85.0) 250 (127) Field Wiring – EMCP Controller Interface
Installer shall use Class 1 wiring methods for all controller (customer) connections with following exception. Class 2 wiring methods shall be allowed for Class 2 controller interface wiring when Class 2 conductors are shielded with UL Listed/recognized insulation sleeve or conduit rated to 600V for each individual circuit.Batteries
Servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.When replacing batteries, use the same number and the following type batteries:Cat Premium High Output (PHO) Batteries
Standard battery (wet) BCI Group 31, Calcium Lead Alloy Grid Design, 1000 CCA,Oversize battery (wet) BCI Group 4D, Calcium Lead Alloy Grid Design, 1400 CCA,Standard battery (dry) BCI Group 31, Calcium Lead Alloy Grid Design, 950 CCA,Oversize battery (dry) BCI Group 4D, Low Maintenance, Hybrid Construction, 1300 CCA,
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or
Caterpillar SIS machinery equipment:
Caterpillar SIS
D9R Track-Type Tractor HWH00001-UP (MACHINE) POWERED BY 3408C Engine »
379-4045
TRACK AR
D9R TRACK-TYPE TRACTOR WDM00001-UP (MACHINE) POWERED BY 3408C Engine »
379-4045
TRACK AR
D9T TRACK-TYPE TRACTOR TWG00001-UP (MACHINE) POWERED BY C18 Engine »
379-4045
TRACK AR
D9T TRACK-TYPE TRACTOR REX00001-UP (MACHINE) POWERED BY C18 Engine »
379-4045
TRACK AR
Caterpillar parts catalog:
Parts track Caterpillar catalog:
1968561
TRACK ADJUSTER & RECOIL GP
D9R, D9T
D9R, D9T
1832123
TRACK GP
D9R, D9T
D9R, D9T
1614370
TRACK GP
D9R, D9T
D9R, D9T
1832121
TRACK GP
D9R, D9T
D9R, D9T
1832127
TRACK GP
D9R, D9T
D9R, D9T
2165571
TRACK GP
D9R
D9R
1995536
TRACK GP
D9R, D9T
D9R, D9T
2289812
TRACK GP
D9R, D9T
D9R, D9T
3794042
TRACK GP
D9R, D9T
D9R, D9T
2662900
TRACK GP
D9R, D9T
D9R, D9T
3794044
TRACK GP
D9R, D9T
D9R, D9T
3794046
TRACK GP
D9R, D9T
D9R, D9T
3794055
TRACK AR
D9R, D9T
D9R, D9T
3794065
TRACK AR
D9R, D9T
D9R, D9T
3794063
TRACK AR
D9R, D9T
D9R, D9T
3794064
TRACK GP
D9R, D9T
D9R, D9T
2081508
TRACK GP
D6R
D6R
4I7348
TRACK GP
312, 312B, E120B
312, 312B, E120B
2465218
TRACK GP
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
1014193
TRACK ADJUSTER & RECOIL GP
D8N, D8R
D8N, D8R
1539311
TRACK GP
583R
583R
3794043
TRACK AR
D9R, D9T
D9R, D9T
3794047
TRACK AR
D9R, D9T
D9R, D9T