3P1135 TRACK GP Caterpillar parts
D6C, D6D
Rating:
Alternative (cross code) number:
CA3P1135
3P-1135
3P1135
CA3P1135
3P-1135
3P1135
Weight: 0.60 pounds 0 kg.
TRACK-TYPE TRACTOR,
Information:
switch is activated. This event will prevent engine operation. Electrical power to the ECM must be removed for three seconds in order to clear this event.
Illustration 1 g03885401
Table 2
Troubleshooting Test Steps Values Results
1. Inspect the Electrical Connectors and the Wiring
A. Turn the main disconnect switch to the OFF position.
B. Verify that the air shutoff mechanisms are set to the OPEN position.
C. Thoroughly inspect the connectors. Refer to Troubleshooting, "Electrical Connectors-Inspect" for additional information.
D. Perform a 45 N (10 lb) pull test on the connector wires.
E. Check the harness for abrasions and pinch points.
Connectors and Wiring
Result: The connectors and wiring appear to be OK.
Proceed to Test Step 2.
Result: There is a problem with the connectors and/or wiring.
Repair: Repair or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.
If the problem is not resolved, proceed to Test Step 2.
2. Test the Operation of the Control Solenoid for the Air Shutoff Relay and Check for Logged Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Restore the electrical power to the ECM.
C. Test the air shutoff system with the emergency stop switch:
a. Start the engine.
b. Place the emergency stop switch in the STOP position.
c. Check the position of the air shutoff mechanisms. Activation of the emergency stop will activate the air shutoff system and the air shutoff mechanisms will close.
d. Check that the solenoid has de-energized after the air shutoff mechanisms are closed.
e. Turn the main disconnect switch to the OFF position.
D. Check the status of the "Air Intake Shutoff Position" parameter.
a. Connect Cat ET.
b. Use Cat ET to check the status of the "Air Intake Shutoff Position" parameter while the air shutoff mechanisms are shut.
c. Reset the air shutoff mechanisms.
d. Use Cat ET to check the status of the "Air Intake Shutoff Position" while the air shutoff mechanisms are open.
E. Use Cat ET to check for the following logged code:
- 970-2
F. Reset the air shutoff mechanisms for the air shutoff to the open position.
a. Place the emergency stop switch in the RUN position.
b. Turn the main disconnect switch to the OFF position.
c. Restore the wiring to the original configuration.
Codes
Result: The valve mechanism did not close when the emergency stop switch is activated. There is a logged 970-2 code.
Proceed to Test Step 3.
Result: The valve mechanisms are operating correctly. There are no codes logged during the test.
Repair: The air shutoff system appears to be operating correctly. There may be an intermittent problem in the wiring harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
If the problem is not resolved, proceed to Test Step 3.
3. Check the Voltage at the Emergency Stop Switch (Customer)
A. Remove the wire from the output terminal at the connector for the emergency stop switch.
B. Restore the electrical power to the ECM.
C. Measure the voltage between the following:
- Emergency shutdown switch output terminal and −Battery
D. As the emergency stop switch is activated,
Illustration 1 g03885401
Table 2
Troubleshooting Test Steps Values Results
1. Inspect the Electrical Connectors and the Wiring
A. Turn the main disconnect switch to the OFF position.
B. Verify that the air shutoff mechanisms are set to the OPEN position.
C. Thoroughly inspect the connectors. Refer to Troubleshooting, "Electrical Connectors-Inspect" for additional information.
D. Perform a 45 N (10 lb) pull test on the connector wires.
E. Check the harness for abrasions and pinch points.
Connectors and Wiring
Result: The connectors and wiring appear to be OK.
Proceed to Test Step 2.
Result: There is a problem with the connectors and/or wiring.
Repair: Repair or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.
If the problem is not resolved, proceed to Test Step 2.
2. Test the Operation of the Control Solenoid for the Air Shutoff Relay and Check for Logged Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Restore the electrical power to the ECM.
C. Test the air shutoff system with the emergency stop switch:
a. Start the engine.
b. Place the emergency stop switch in the STOP position.
c. Check the position of the air shutoff mechanisms. Activation of the emergency stop will activate the air shutoff system and the air shutoff mechanisms will close.
d. Check that the solenoid has de-energized after the air shutoff mechanisms are closed.
e. Turn the main disconnect switch to the OFF position.
D. Check the status of the "Air Intake Shutoff Position" parameter.
a. Connect Cat ET.
b. Use Cat ET to check the status of the "Air Intake Shutoff Position" parameter while the air shutoff mechanisms are shut.
c. Reset the air shutoff mechanisms.
d. Use Cat ET to check the status of the "Air Intake Shutoff Position" while the air shutoff mechanisms are open.
E. Use Cat ET to check for the following logged code:
- 970-2
F. Reset the air shutoff mechanisms for the air shutoff to the open position.
a. Place the emergency stop switch in the RUN position.
b. Turn the main disconnect switch to the OFF position.
c. Restore the wiring to the original configuration.
Codes
Result: The valve mechanism did not close when the emergency stop switch is activated. There is a logged 970-2 code.
Proceed to Test Step 3.
Result: The valve mechanisms are operating correctly. There are no codes logged during the test.
Repair: The air shutoff system appears to be operating correctly. There may be an intermittent problem in the wiring harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
If the problem is not resolved, proceed to Test Step 3.
3. Check the Voltage at the Emergency Stop Switch (Customer)
A. Remove the wire from the output terminal at the connector for the emergency stop switch.
B. Restore the electrical power to the ECM.
C. Measure the voltage between the following:
- Emergency shutdown switch output terminal and −Battery
D. As the emergency stop switch is activated,
Caterpillar SIS machinery equipment:
Caterpillar SIS
D6D TRACTOR / POWER SHIFT / 20X03042-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR DIRECT DRIVE 03X01009-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR / POWER SHIFT / 04X06608-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR / DIRECT DRIVE / 30X02070-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACK-TYPE TRACTOR / POWERSHIFT / 31X01497-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACK-TYPE TRACTOR / POWERSHIFT / 31X03833-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR / DIRECT DRIVE / 30X00001-02069 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR / DIRECT DRIVE / 30X00001-02069 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACK-TYPE TRACTOR / POWERSHIFT / 31X00001-01496 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACK-TYPE TRACTOR / POWERSHIFT / 31X00001-01496 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6C TRACTOR / DIRECT DRIVE / 23U00001-00267 (MACHINE) »
3P-1135
TRACK GROUP
D6C TRACTOR / DIRECT DRIVE / 23U00268-UP (MACHINE) »
3P-1135
TRACK GROUP
D6C TRACTOR / POWER SHIFT / 24U00001-00712 (MACHINE) »
3P-1135
TRACK GROUP
D6C TRACTOR / POWER SHIFT / 24U00713-UP (MACHINE) »
3P-1135
TRACK GROUP
D6D TRACTOR / POWER SHIFT / 75W00001-04535 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTOR / DIRECT DRIVE / 74W00001-02560 (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTORS / POWER SHIFT / 36C00100-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
D6D TRACTORS / DIRECT DRIVE / 37C00200-UP (MACHINE) POWERED BY 3306 ENGINE »
3P-1135
TRACK GP
Parts track Caterpillar catalog:
7G0423
TRACK ROLLER GP-DOUBLE FLANGE
D6D, D6D SR, D6E
D6D, D6D SR, D6E
3P1137
TRACK GP
D6D, D6D SR
D6D, D6D SR
3P1098
TRACK GP
D6D
D6D
3P1150
TRACK GROUP
D6C, D6D
D6C, D6D
7T1040
TRACK GP
D6D
D6D
6T1563
TRACK GP
D6D
D6D
3794058
TRACK GP
D9R, D9T
D9R, D9T
3328910
TRACK GP
324D, 324D L, 324D LN, 329D L, 345D L
324D, 324D L, 324D LN, 329D L, 345D L
7K1312
TRACK SPROCKET GROUP
955H, 955K, 955L
955H, 955K, 955L
9W6134
TRACK GP
215C, 219D, 225D, 229
215C, 219D, 225D, 229
3855453
TRACK GP
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
D6R, D6R II, D6R III, D6T, D6T LGP, D6T XL
3843002
TRACK GP
D8R, D8T
D8R, D8T
3503237
TRACK GP
345D, 349D
345D, 349D
3032634
TRACK GP
345D L, 349D, 349D L