Schematic of the Solenoid Valve for One-way Flow or Two-way FlowThis diagnostic code is associated with the solenoid valve for one-way flow or two-way flow. This diagnostic code is recorded when the implement ECM reads the current of the solenoid as being above normal. There is a short to ground. The possible causes of this diagnostic code are listed:
The signal circuit of the solenoid is shorted to ground.
The solenoid has failed.
The implement ECM has failed. This is unlikely. System Response:When this diagnostic code occurs, there is no warning on the monitor. The diagnostic code will only be active when the control for the work tool is actuated. An example of this action is pressing the pedal for operating a hammer. The diagnostic code is active when the pedal is pressed. When the pedal is no longer pressed, the diagnostic code is not active, but the code is present in the diagnostic code log ("LOGGED ERROR" screen). Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic code is corrected.Test Step 1. CHECK THE SOLENOID.
Turn
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts track Caterpillar catalog:
4195105
TRACK GP
Caterpillar
Caterpillar
4195104
TRACK GP
Caterpillar
Caterpillar
3911653
TRACK GP
Caterpillar
Caterpillar
3370982
TRACK ADJUSTER & RECOIL GP
Caterpillar
Caterpillar
3196672
TRACK GP
Caterpillar
Caterpillar
5569373
TRACK AR
Caterpillar
Caterpillar
4953888
TRACK GP
Caterpillar
Caterpillar
4953886
TRACK GP
Caterpillar
Caterpillar
4953882
TRACK GP
Caterpillar
Caterpillar
4587804
TRACK GP
Caterpillar
Caterpillar
4587790
TRACK GP
Caterpillar
Caterpillar
4587494
TRACK ADJUSTER & RECOIL GP
Caterpillar
Caterpillar