6Y6417 TRACK GP Caterpillar parts
D6H
Rating:
Alternative (cross code) number:
CA6Y6417
6Y-6417
6Y6417
CA6Y6417
6Y-6417
6Y6417
TRACK-TYPE TRACTOR,
Compatible equipment models: 6Y6417:
Information:
Battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 4C4911 Battery Load Tester to load test a battery that does not hold a charge when in use. Refer to Operating Manual, Form No. SEHS9249 for more detailed instructions on use of the 4C4911 Battery Load Tester. See Special Instruction, Form No. SEHS7633, Battery Test Procedure, for the correct procedure and specifications to use when testing batteries.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.To check for correct output of the alternator, see the Specifications module.For complete service information, refer to Service Manual Module, Form No. SENR3862, Delco Remy 27-SI Series Alternators. This module is part of REG00636 Service Manual.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp.Gr.) fully charged and held tightly in place. The Battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches, and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Alternator Regulator Adjustment (Delco-Remy)
When an alternator is charging the battery
Never disconnect any charging unit circuit or battery circuit cable from the battery when the charging unit is operated. A spark can cause an explosion from the flammable vapor mixture of hydrogen and oxygen that is released from the electrolyte through the battery outlets. Injury to personnel can be the result.
The battery circuit is an electrical load on the charging unit. The load is variable because of the condition of the charge in the battery. Damage to the charging unit will result if the connections (either positive or negative) between the battery and charging unit are broken while the charging unit is in operation. This is because the battery load is lost and there is an increase in charging voltage. High voltage will damage, not only the charging unit, but also the regulator and other electrical components.Use the 4C4911 Battery Load Tester to load test a battery that does not hold a charge when in use. Refer to Operating Manual, Form No. SEHS9249 for more detailed instructions on use of the 4C4911 Battery Load Tester. See Special Instruction, Form No. SEHS7633, Battery Test Procedure, for the correct procedure and specifications to use when testing batteries.Charging System
The condition of charge in the battery at each regular inspection will show if the charging system operates correctly. An adjustment is necessary when the battery is constantly in a low condition of charge or a large amount of water is needed (more than one ounce of water per cell per week or per every 100 service hours).When it is possible, make a test of the charging unit and voltage regulator on the engine, and use wiring and components that are a permanent part of the system. Off-engine (bench) testing will give a test of the charging unit and voltage regulator operation. This testing will give an indication of needed repair. After repairs are made, again make a test to give proof that the units are repaired to their original condition of operation.To check for correct output of the alternator, see the Specifications module.For complete service information, refer to Service Manual Module, Form No. SENR3862, Delco Remy 27-SI Series Alternators. This module is part of REG00636 Service Manual.Before the start of on-engine testing, the charging system and battery must be checked as shown in the Steps that follow:1. Battery must be at least 75% (1.225 Sp.Gr.) fully charged and held tightly in place. The Battery holder must not put too much stress on the battery.2. Cables between the battery, starter and engine ground must be the correct size. Wires and cables must be free of corrosion and have cable support clamps to prevent stress on battery connections (terminals).3. Leads, junctions, switches, and panel instruments that have direct relation to the charging circuit must give correct circuit control.4. Inspect the drive components for the charging unit to be sure they are free of grease and oil and have the ability to operate the charging unit.Alternator Regulator Adjustment (Delco-Remy)
When an alternator is charging the battery
Caterpillar SIS machinery equipment:
Caterpillar SIS
D6H & D6H LGP TRACTORS / POWER SHIFT / 2TG00001-03999 (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H TRACTOR / DIRECT DRIVE / 1FJ00001-03999 (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP TRACTORS / POWER SHIFT / 4RC00001-03999 (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H TRACTOR / DIRECT DRIVE / 8KB00001-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H, D6H LGP TRACTORS DIFFERENTIAL STEERING 3YG00001-03999 (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H TRACTOR 5HF00001-03999 (MACHINE) »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS /DIFFERENTIAL STEERIN/ 3YG04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS /DIFFERENTIAL STEERIN/ 3YG04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS / POWER SHIFT / 4RC04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS / POWER SHIFT / 4RC04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H D6H LGP Series II Track-Type Tractors 5HF04000-UP (MACHINE) POWERED BY 3306 Engine »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS / POWERSHIFT / 2TG04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS / POWERSHIFT / 2TG04000-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H Series II Track-Type Tractor Direct Drive 1FJ04000-UP (MACHINE) POWERED BY 3306 Engine »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTORS / POWERSHIFT / 1KD04074-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H TRACK-TYPE TRACTOR / DIRECT DRIVE / 3ED04083-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTOR / POWERSHIFT / 4GG05500-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
D6H & D6H LGP SERIES II TRACTOR / POWERSHIFT / 1KD05500-UP (MACHINE) POWERED BY 3306 ENGINE »
6Y-6417
TRACK GP
Parts track Caterpillar catalog:
7G5526
TRACK ADJUSTER & RECOIL GP
D6H, D6H II, D6H XL
D6H, D6H II, D6H XL
4Y2284
TRACK GP
D6H
D6H
6Y1629
TRACK GP
D6H
D6H
6T8205
TRACK GP
D6H
D6H
9W3911
TRACK GP
D6H
D6H
6Y5502
TRACK GP
D6H
D6H
9W4082
TRACK GP
D6H
D6H
6Y3539
TRACK GP
D6H
D6H
1010897
TRACK AR
D6H
D6H
6I9641
TRACK GP
D6H, D6R, D6R II, D6R III, D6R STD, D6T
D6H, D6R, D6R II, D6R III, D6R STD, D6T
1010894
TRACK AR
D6H
D6H
1181992
TRACK GP
D6H
D6H
3519700
TRACK AR
329D L, 329D LN
329D L, 329D LN
3P0959
TRACK GP
572G
572G
3572767
TRACK GP
D5R LGP, D6N, D6N LGP
D5R LGP, D6N, D6N LGP
3843010
TRACK GP
D8R, D8T
D8R, D8T
3503295
TRACK AR
311D LRR, 312D, 312D L, 312D2, 312D2 GC, 313D2
311D LRR, 312D, 312D L, 312D2, 312D2 GC, 313D2
3951051
TRACK AR
D11T
D11T
9G9091
TRACK GP
D6H
D6H
1081812
TRACK ADJUSTER & RECOIL GP
572R, 572R II, D7R, D7R II, D7R XR
572R, 572R II, D7R, D7R II, D7R XR
9H9415
TRACK CARRIER ROLLER GROUP
583H, D8H
583H, D8H
6Y1630
TRACK GP
D6H
D6H
6I9917
TRACK GP
D7H, D7R, D7R II
D7H, D7R, D7R II