9W4168 TRACK GP Caterpillar parts
D10N, D10R
Rating:
Alternative (cross code) number:
CA9W4168
9W-4168
9W4168
CA9W4168
9W-4168
9W4168
Weight: 9760 pounds 4427 kg.
TRACK-TYPE TRACTOR,
Information:
give nameplate rated amperes but because of the voltage reduction the available kW and KVA will be 92% of the nameplate rating.If the wire on the 139V tap is moved to the 120V tap, the generator will operate as a 208-416 unit. The generator can give nameplate rated amperes but because of the voltage reduction the available kW and KVA will be 87% of the nameplate rating. Make a mark (show new location) on the nameplate of the generator when saturable reactor taps are changed from the original position.
240 VOLT GENERATOR CONNECTION
2 and 10. Regulator terminals. M. Generator armature. T0, T1, T2 and T3. Generator leads (outside generator). t1 through t9. Phase winding leads (inside generator).
480 VOLT GENERATOR CONNECTION A. Saturable reactor.B. Voltage droop resistor (if so equipped).C. DC controlled reactor.D. Voltage droop rheostat.E. Full wave rectifier.F. Voltage level resistor (if so equipped).G. Blocking rectifier.H. Voltage level rheostat.I. Generator field.J. Exciter armature.K. Exciter field.L. Exciter control field.M. Generator armature.1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11. Regulator terminals.
A1 and A2. Exciter armature leads.
C1 and C2. Generator field leads.
F1 and F2. Exciter field leads.
S1 and S2. Exciter control field leads.
t1 through t9. Phase winding leads (inside generator).
T0, T1, T2 and T3. Generator leads (outside generator).600 or 2400 Volt Generators
Saturable reactor (A) has the common tap connected to DC controlled reactor (C). The 120V tap (127V tap on the D375 2400V generator) is connected to the phase windings of (T2) through regulator terminal (10). The generator neutral (T0) is connected to the regulator through regulator terminal (2). For more information on the exact location of the phase winding tap for the regulator reference lead make reference to REWIND INFORMATION.This arrangement gives no more than 139V at the saturable reactor. This is the highest voltage in the regulator compartment.
A 2400 volt generator must not be operated, even on open circuit, without a good ground connection made to (T0).
600 or 2400 VOLT GENERATOR CONNECTION A. Saturable reactor.B. Voltage droop resistor (if so equipped).C. DC Controlled reactor.D. Voltage droop rheostat.E. Full wave rectifier.F. Voltage level resistor (if so equipped).G. Blocking rectifier.H. Voltage level rheostat.I. Generator field.J. Exciter armature.K. Exciter field.L. Exciter control field.M. Generator armature. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11. Regulator terminals. A1 and A2. Exciter armature leads. C1 and C2. Generator field leads. F1 and F2. Exciter field leads. S1 and S2. Exciter control field leads. T0, T1, T2 and T3. Generator leads (outside generator.)Single Phase Generators
A three phase generator can be connected to give 2 or 3 wire single phase current. When a three phase generator is connected for single phase operation, it will give 57% of its three phase kW and KVA rating.120-240 Volt Generators
2 WIRE LOW VOLTAGE
10 and 2. Regulator reference leads. t1 through t9. Phase winding leads (inside generator). T0, L1 and L2. Generator leads (outside generator)The 2 wire low voltage connection will give 120V line to line. The phase winding leads are connected in parallel. The
240 VOLT GENERATOR CONNECTION
2 and 10. Regulator terminals. M. Generator armature. T0, T1, T2 and T3. Generator leads (outside generator). t1 through t9. Phase winding leads (inside generator).
480 VOLT GENERATOR CONNECTION A. Saturable reactor.B. Voltage droop resistor (if so equipped).C. DC controlled reactor.D. Voltage droop rheostat.E. Full wave rectifier.F. Voltage level resistor (if so equipped).G. Blocking rectifier.H. Voltage level rheostat.I. Generator field.J. Exciter armature.K. Exciter field.L. Exciter control field.M. Generator armature.1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11. Regulator terminals.
A1 and A2. Exciter armature leads.
C1 and C2. Generator field leads.
F1 and F2. Exciter field leads.
S1 and S2. Exciter control field leads.
t1 through t9. Phase winding leads (inside generator).
T0, T1, T2 and T3. Generator leads (outside generator).600 or 2400 Volt Generators
Saturable reactor (A) has the common tap connected to DC controlled reactor (C). The 120V tap (127V tap on the D375 2400V generator) is connected to the phase windings of (T2) through regulator terminal (10). The generator neutral (T0) is connected to the regulator through regulator terminal (2). For more information on the exact location of the phase winding tap for the regulator reference lead make reference to REWIND INFORMATION.This arrangement gives no more than 139V at the saturable reactor. This is the highest voltage in the regulator compartment.
A 2400 volt generator must not be operated, even on open circuit, without a good ground connection made to (T0).
600 or 2400 VOLT GENERATOR CONNECTION A. Saturable reactor.B. Voltage droop resistor (if so equipped).C. DC Controlled reactor.D. Voltage droop rheostat.E. Full wave rectifier.F. Voltage level resistor (if so equipped).G. Blocking rectifier.H. Voltage level rheostat.I. Generator field.J. Exciter armature.K. Exciter field.L. Exciter control field.M. Generator armature. 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 11. Regulator terminals. A1 and A2. Exciter armature leads. C1 and C2. Generator field leads. F1 and F2. Exciter field leads. S1 and S2. Exciter control field leads. T0, T1, T2 and T3. Generator leads (outside generator.)Single Phase Generators
A three phase generator can be connected to give 2 or 3 wire single phase current. When a three phase generator is connected for single phase operation, it will give 57% of its three phase kW and KVA rating.120-240 Volt Generators
2 WIRE LOW VOLTAGE
10 and 2. Regulator reference leads. t1 through t9. Phase winding leads (inside generator). T0, L1 and L2. Generator leads (outside generator)The 2 wire low voltage connection will give 120V line to line. The phase winding leads are connected in parallel. The
Caterpillar SIS machinery equipment:
Parts track Caterpillar catalog:
6Y0617
TRACK ADJUSTER & RECOIL GP
D10N, D10R
D10N, D10R
8E6250
TRACK ADJUSTER & RECOIL GP
D10N, D10R, D10T
D10N, D10R, D10T
8E6249
TRACK ADJUSTER & RECOIL GP
D10N, D10R, D10T
D10N, D10R, D10T
9W4170
TRACK GP
D10N, D10R
D10N, D10R
6Y8188
TRACK GP
D10N
D10N
6Y8187
TRACK GP
D10N
D10N
7T4606
TRACK GP
D10N, D10R, D10T
D10N, D10R, D10T
1565708
TRACK ADJUSTER & RECOIL GP
D10R, D10T
D10R, D10T
1565709
TRACK ADJUSTER & RECOIL GP
D10R, D10T
D10R, D10T
1968563
TRACK ADJUSTER & RECOIL GP
D10R, D10T
D10R, D10T
2207079
TRACK GP
D10R
D10R
3754607
TRACK GP
D6N LGP
D6N LGP
2979187
TRACK ADJUSTER & RECOIL GP
313D2 LGP, 315D L, 316E L, 318D L, 318D2 L
313D2 LGP, 315D L, 316E L, 318D L, 318D2 L
6I9647
TRACK GP
D6H XR, D6R
D6H XR, D6R
6Y4112
TRACK GP
D7H
D7H
6Y4107
TRACK GP
D7H
D7H
6Y4114
TRACK GP
D7H
D7H
1133190
TRACK GP
325B, 325B L, OEMS
325B, 325B L, OEMS
2347531
TRACK GP
330D MH, 345C, 345C L, 345C MH
330D MH, 345C, 345C L, 345C MH
9G9095
TRACK GP
D6H
D6H
2352557
TRACK GP
D5K LGP, D5K2 XL
D5K LGP, D5K2 XL
7T9166
TRACK GP
D6H
D6H