9W9356 TRACK GP Caterpillar parts
320, 320 L, 320B, 320B FM LL, 320B U, 320C, 320N, OEMS
Rating:
Alternative (cross code) number:
CA9W9356
9W-9356
9W9356
CA9W9356
9W-9356
9W9356
Weight: 465 pounds 210 kg.
EXCAVATOR, UNDERCARRIAGE,
Compatible equipment models: 9W9356:
Information:
Implement ECM
Table 1
Implement ECM (MID 82)
DTC Code Description System Response
1529-3 Quick Coupler Switch : Voltage Above Normal Load sense solenoid is de-energized, the operator will not be able to change the work tool.
This code is triggered when both pins are open.
1529-4 Quick Coupler Switch : Voltage Below Normal Load sense solenoid is de-energized, the operator will not be able to change the work tool.
This code is triggered when both pins are grounded. Possible Causes for an FMI 3 Diagnostic code are:
Both signal contacts are shorted to battery.
The switch has failed.
The ECM has failed. A failure of the Implement ECM is unlikely.Possible Causes for an FMI 4 Diagnostic code are:
Both signal contacts are open.
The switch has failed.
The ECM has failed. A failure of the Implement ECM is unlikely.
Illustration 1 g06078763
Schematic for Operator Control Switch (Switch to Battery) Connections
Note: The diagram above is a simplified schematic of the ECM switch connections. The schematic is electrically correct, however, not all the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR6723 for the complete schematic.
Table 2
Switch Operation For the Quick Coupler Switch (CID 1529)
Contacts Switch State Continuity
1, 2 Engage Yes
1, 2 Retract No
2, 3 Engage No
2, 3 Retract Yes Diagnostic Trouble Code Procedure
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Table 3
Troubleshooting Test Steps Values Results
1. Identify Active FMI Code Associated With Sensor Circuit
Code present. FMI 3 diagnostic code, proceed to Test Step 2.
FMI 4 diagnostic code, proceed to Test Step 4.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Circuit For A Short
A. Turn the key start switch and disconnect switch OFF.
B. Disconnect the switch from the machine harness.
C. Disconnect the J1 and J2 machine harness connections from the Implement ECM.
C. At the machine harness connector for the ECM, one at a time, measure the resistance between each of the signal contacts to every other contact used in the J1 and J2 machine harness connectors.
The resistance is greater than 5 K Ω. OK - The resistance is correct.
Proceed to Test Step 3.
NOT OK - The resistance check is not correct.
Repair: There is a short in the signal circuits of the machine harness. Repair or replace the machine harness.
STOP
3. Check the Operation of the Switch.
A. The key start switch and disconnect switch remain OFF.
B. Reconnect all harness connectors.
C. Check the operation of the switch. Refer to the table for the suspected faulty switch at the beginning of this procedure for switch operation.
The switch operates correctly. OK - The switch is operating correctly.
Proceed to Test Step 9.
NOT OK - The switch is not
Table 1
Implement ECM (MID 82)
DTC Code Description System Response
1529-3 Quick Coupler Switch : Voltage Above Normal Load sense solenoid is de-energized, the operator will not be able to change the work tool.
This code is triggered when both pins are open.
1529-4 Quick Coupler Switch : Voltage Below Normal Load sense solenoid is de-energized, the operator will not be able to change the work tool.
This code is triggered when both pins are grounded. Possible Causes for an FMI 3 Diagnostic code are:
Both signal contacts are shorted to battery.
The switch has failed.
The ECM has failed. A failure of the Implement ECM is unlikely.Possible Causes for an FMI 4 Diagnostic code are:
Both signal contacts are open.
The switch has failed.
The ECM has failed. A failure of the Implement ECM is unlikely.
Illustration 1 g06078763
Schematic for Operator Control Switch (Switch to Battery) Connections
Note: The diagram above is a simplified schematic of the ECM switch connections. The schematic is electrically correct, however, not all the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR6723 for the complete schematic.
Table 2
Switch Operation For the Quick Coupler Switch (CID 1529)
Contacts Switch State Continuity
1, 2 Engage Yes
1, 2 Retract No
2, 3 Engage No
2, 3 Retract Yes Diagnostic Trouble Code Procedure
Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Table 3
Troubleshooting Test Steps Values Results
1. Identify Active FMI Code Associated With Sensor Circuit
Code present. FMI 3 diagnostic code, proceed to Test Step 2.
FMI 4 diagnostic code, proceed to Test Step 4.
Begin Process For FMI 3 Troubleshooting HERE
2. Check The Circuit For A Short
A. Turn the key start switch and disconnect switch OFF.
B. Disconnect the switch from the machine harness.
C. Disconnect the J1 and J2 machine harness connections from the Implement ECM.
C. At the machine harness connector for the ECM, one at a time, measure the resistance between each of the signal contacts to every other contact used in the J1 and J2 machine harness connectors.
The resistance is greater than 5 K Ω. OK - The resistance is correct.
Proceed to Test Step 3.
NOT OK - The resistance check is not correct.
Repair: There is a short in the signal circuits of the machine harness. Repair or replace the machine harness.
STOP
3. Check the Operation of the Switch.
A. The key start switch and disconnect switch remain OFF.
B. Reconnect all harness connectors.
C. Check the operation of the switch. Refer to the table for the suspected faulty switch at the beginning of this procedure for switch operation.
The switch operates correctly. OK - The switch is operating correctly.
Proceed to Test Step 9.
NOT OK - The switch is not
Caterpillar SIS machinery equipment:
Caterpillar SIS
320B Material Handler 6LS00001-UP (MACHINE) POWERED BY 3066 Engine »
9W-9356
TRACK GP
CIPI Undercarriages L5E00001-UP (MACHINE) »
9W-9356
TRACK GP
320, 320L & 320N EXCAVATORS 3XK00001-00821 (MACHINE) »
9W-9356
TRACK GP
320, 320 L, 320 N AND 320 S EXCAVATORS 3XK00822-UP (MACHINE) POWERED BY 3116 ENGINE »
9W-9356
TRACK GP
320B, 320B L, 320B LN, 320B N & 320B S Excavators 1XS00001-UP (MACHINE) POWERED BY 3116 Engine »
9W-9356
TRACK GP
320C, 320C L, 320C LN, 320C S Excavators BBL00001-UP (MACHINE) POWERED BY 3066 Engine »
9W-9356
TRACK GP
320, 320L TRACK-TYPE EXCAVATORS 1KL00001-UP (MACHINE) POWERED BY 3066 ENGINE »
9W-9356
TRACK GP
320, 320L TRACK-TYPE EXCAVATORS 1TL00001-UP (MACHINE) POWERED BY 3116 ENGINE »
9W-9356
TRACK GP
320, 320L TRACK-TYPE EXCAVATORS 2DL00001-00213 (MACHINE) POWERED BY 3066 ENGINE »
9W-9356
TRACK GP
320, 320L & 320N TRACK-TYPE EXCAVATORS 1XM00001-UP (MACHINE) POWERED BY 3066 ENGINE »
9W-9356
TRACK GP
320B & 320B L TRACK-TYPE EXCAVATORS 5BR00001-UP (MACHINE) POWERED BY 3066 ENGINE »
9W-9356
TRACK GP
320B U 320B LU TRACK-TYPE EXCAVATORS BAN00001-UP (MACHINE) POWERED BY 3066 ENGINE »
9W-9356
TRACK GP
Caterpillar parts catalog:
Parts track Caterpillar catalog:
1453028
TRACK ADJUSTER & RECOIL GP
315C, 318C, 319C, 320C, 321B
315C, 318C, 319C, 320C, 321B
7Y1602
TRACK ADJUSTER & RECOIL GP
320, 320 L, 320N
320, 320 L, 320N
1453027
TRACK ADJUSTER & RECOIL GP
315C, 318C, 319C, 320C, 321B
315C, 318C, 319C, 320C, 321B
1941912
TRACK GP
318B, 318C, 319D, 320B, 320B U, 320C, 320C FM, 320C L, 320D, 320D L, 320D LRR, 321B, 321C, 321D LCR, 323D L
318B, 318C, 319D, 320B, 320B U, 320C, 320C FM, 320C L, 320D, 320D L, 320D LRR, 321B, 321C, 321D LCR, 323D L
1453039
TRACK ADJUSTER & RECOIL GP
315C, 318C, 319C, 320C, 321B
315C, 318C, 319C, 320C, 321B
1156425
TRACK ADJUSTER & RECOIL GP
318B, 320B, 320B L, 320B U, OEMS
318B, 320B, 320B L, 320B U, OEMS
1941921
TRACK GP
317B LN, 318B, 320B, 320B U, 320C, 320D, 320D LRR, 320D RR
317B LN, 318B, 320B, 320B U, 320C, 320D, 320D LRR, 320D RR
1225136
TRACK ADJUSTER & RECOIL GP
320 L, 320N, OEMS
320 L, 320N, OEMS
1028117
TRACK ADJUSTER & RECOIL GP
311, 311B, 312, 315, 317, OEMS
311, 311B, 312, 315, 317, OEMS
7Y1457
TRACK ADJUSTER GP
330, 330 FM L, 330 L, 330B, 330B L, OEMS
330, 330 FM L, 330 L, 330B, 330B L, OEMS
1028167
TRACK ADJUSTER & RECOIL GP
322, 322 FM L, 322 LN, 322B L, 322B LN, OEMS
322, 322 FM L, 322 LN, 322B L, 322B LN, OEMS
1028165
TRACK ADJUSTER & RECOIL GP
311, 311B, 312, 315, 317, 320 L, 320N, OEMS
311, 311B, 312, 315, 317, 320 L, 320N, OEMS
2352540
TRACK GP
D6K, D6K LGP, D6K2, D6K2 LGP
D6K, D6K LGP, D6K2, D6K2 LGP
2398215
TRACK ADJUSTER & RECOIL GP
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61
1M0388
TRACK GROUP
955H
955H
1Q4647
TRACK GP
D10R
D10R
3896864
TRACK GP
324D FM
324D FM
1395022
TRACK GP
301.5
301.5
6Y5806
TRACK GP
219D, 225D
219D, 225D