7V7081 TRACTOR AR- Caterpillar parts
Rating:
Alternative (cross code) number:
CA7V7081
7V-7081
7V7081
CA7V7081
7V-7081
7V7081
Information:
TYPE="1" START="1">
Turn the keyswitch to the OFF position.
Connect the 9U-5795 Current Probe to a DMM (digital multimeter) or use a 225-8266 Ammeter Tool Gp . Clamp the probe around the alternator output wire ("B+"). Before you clamp the probe around the wire, ensure that the probe is "zeroed" .
Read the current.Expected Result: The current is under 2 A.Results:
YES - The current is under 2 A. Continue to Step 4.
NO - The current is over 2 A. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test".
Disconnect the B+ terminal wire from the alternator. Connect the red lead of the multimeter to the wire that was disconnected. Connect the black lead of the multimeter to the alternators B+ terminal. Set the multimeter on the 10 amp scale. Read the current. Expected Result: The current is under 0.015 A.Results:
YES - The current is under 0.015 A. The alternator is operating correctly. There is a current draw on the machine. Go to Testing and Adjusting, "T7 Identifying Source Of Current Draw - Test".
NO - The current is over 0.015 A. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test".
Turn the keyswitch to the OFF position.
Connect the 9U-5795 Current Probe to a DMM (digital multimeter) or use a 225-8266 Ammeter Tool Gp . Clamp the probe around the alternator output wire ("B+"). Before you clamp the probe around the wire, ensure that the probe is "zeroed" .
Read the current.Expected Result: The current is under 2 A.Results:
YES - The current is under 2 A. Continue to Step 4.
NO - The current is over 2 A. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test".
Disconnect the B+ terminal wire from the alternator. Connect the red lead of the multimeter to the wire that was disconnected. Connect the black lead of the multimeter to the alternators B+ terminal. Set the multimeter on the 10 amp scale. Read the current. Expected Result: The current is under 0.015 A.Results:
YES - The current is under 0.015 A. The alternator is operating correctly. There is a current draw on the machine. Go to Testing and Adjusting, "T7 Identifying Source Of Current Draw - Test".
NO - The current is over 0.015 A. There is an internal problem with the alternator. Replace the alternator or go to Testing and Adjusting, "Component - Test".
Parts tractor Caterpillar catalog:
7U2680
TRACTOR GP-
Caterpillar
Caterpillar
7U2675
TRACTOR GP
Caterpillar
Caterpillar
7U1916
TRACTOR GP
Caterpillar
Caterpillar
7U1915
TRACTOR GP
Caterpillar
Caterpillar
7U1914
TRACTOR GP
Caterpillar
Caterpillar
7U0208
TRACTOR GP
Caterpillar
Caterpillar
8V9030
TRACTOR AR
Caterpillar
Caterpillar
8V5725
TRACTOR AR-
Caterpillar
Caterpillar
8V4005
TRACTOR AR-
Caterpillar
Caterpillar
8D2430
TRACTOR AR W/
Caterpillar
Caterpillar
8D2410
TRACTOR AR
Caterpillar
Caterpillar
8D2360
TRACTOR AR
Caterpillar
Caterpillar