Illustration 1 g02802434
Schematic for the Auto Lube Pump Outlet Pressure SensorThis diagnostic code is associated with the Auto Lube Pump Outlet Pressure Sensor. The FMI 04 means that the ECM has determined that the signal of the sensor is below the normal range.The output frequency of the pressure sensor is approximately 500 Hz. The duty cycle of the signal changes as the pressure changes.The possible causes of this diagnostic code are listed below:
The signal circuit for the sensor is shorted to ground.
The sensor has failed.
The ECM has failed. This situation is unlikely.Note: The following test procedure may create other diagnostic codes. Clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 2984 FMI 04 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The diagnostic code will be logged into the internal memory of the ECM.Test Step 1. CHECK THE SENSOR
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Disconnect the sensor from the machine harness.Expected Result:The CID 2984 FMI 04 diagnostic code remains active. The FMI has not changed and the FMI 04 diagnostic code is still active.Results:
OK - The diagnostic code remains active. The sensor is correct. Proceed to Test Step 2.
NOT OK - The diagnostic code is no longer active. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE WIRING HARNESS OF THE SENSOR FOR A SHORT TO GROUND
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the sensor.
Disconnect the machine harness connectors from the ECM.
Operate the machine and take the sensor through the operating range of the sensor.
At the machine harness connector for the ECM, measure the resistance from the signal contact "J1-36" (wire E456-WH) of the machine harness to all possible sources of ground. Measure the resistance to all contacts of the machine harness connectors for the ECM.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - One or more resistance measurements are not correct. There is a short in the machine harness. Repair: The short is between signal contact "J1-36" (wire E456-WH) and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS
Inspect the contacts of the harness connectors and clean the contacts.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 2984 FMI 04 diagnostic code.Expected Result:The CID 2984 FMI 04 diagnostic code is active.Results:
OK - The CID 2984 FMI 04 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: Failure of the ECM is unlikely. Exit this procedure and perform this procedure again.
Parts trunnion Caterpillar catalog:
9J3638
TRUNNION
Caterpillar
Caterpillar
9J2728
TRUNNION A LH
Caterpillar
Caterpillar
9J2727
TRUNNION A RH
Caterpillar
Caterpillar
9J2431
TRUNNION
Caterpillar
Caterpillar
9J1686
TRUNNION A
Caterpillar
Caterpillar
9F9820
TRUNNION G.
Caterpillar
Caterpillar
9T0767
TRUNNION A
Caterpillar
Caterpillar
9T0765
TRUNNION
Caterpillar
Caterpillar
9T0513
TRUNNION A
Caterpillar
Caterpillar
9T0337
TRUNNION A
Caterpillar
Caterpillar
9T0316
TRUNNION A-RH
Caterpillar
Caterpillar
9J6559
TRUNNION A
Caterpillar
Caterpillar