Information:
Illustration 1 g02165173
Electrical System Voltage Supply to the RH Operator ECMThis diagnostic code is recorded when the RH Operator ECM reads the electrical system voltage that is at contact J1-31 (wire 152-BU) as being below normal range (less than 18 volts for 2 seconds).Note: The RH Operator ECM is located under the RH Operator Platform.The possible causes of this diagnostic code are listed:
A charging system component has failed.
The ECM has failed. This situation is unlikely.This diagnostic code causes the implements to be inoperative because the voltage is too low in order to energize the solenoids.System Response:When this diagnostic code is active, the following occurs:
Components connected to controller will not log faults.
Machine may become inoperable.Test Step 1. CHECK THE BATTERY VOLTAGE.
Measure the voltage at the battery posts.Expected Result:The voltage is greater than 18 VDC.Results:
YES - The voltage is greater than 18 DCV. This situation should not cause the diagnostic code. Proceed to test step 2.
NO - The voltage is less than 18 DCV. The charging system is not correct. Repair: Check the charging system. See Special Instruction, REHS0354, "Charging System Troubleshooting". STOPTest Step 2. CHECK THE SYSTEM VOLTAGE
Disconnect the machine harness from the ECM.
Turn the disconnect switch and the key start switch to the ON position.
At machine harness connector J1 for the ECM, measure the voltage between contact J1-31 (wire 152-BU) and contact J1-23 (wire 200-BK).Expected Result:The voltage measures battery voltage.Results:
YES - The voltage is greater 18 DCV. This situation should not cause the diagnostic code. Repair: Inspect connector J1. Connect the machine harness to the ECM. If the CID 0168 FMI F01 remains present, check the charging system. See Special Instruction, REHS0354, "Charging System Troubleshooting". If the cause of the diagnostic code is not found, the ECM may have failed. Exit this procedure and perform this entire procedure again. Prior to replacing an ECM, always contact the Technical Communicator for your dealer for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacement, refer to Troubleshooting, "Electronic Control Module (ECM) - Replace".STOP
NO - The voltage is less than 18 DCV. The machine harness has failed. Repair: Check the +battery circuit and the ground circuit in the machine harness. Repair the machine harness or replace the machine harness. STOP
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
1193662
TUBE-HEAT SHRINK
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
1186693
TUBE AS
M312, M315, M318, M320
M312, M315, M318, M320
1496845
TUBE
M312, M315, M318
M312, M315, M318
1473785
TUBE AS
M312, M315
M312, M315
1293482
TUBE AS
M312, M315
M312, M315
1246980
TUBE AS
M312
M312
1223593
TUBE AS
M312
M312
1246968
TUBE AS
M312
M312
1242518
TUBE AS
M312
M312
1249569
TUBE
M312
M312
1532064
TUBE AS
M312
M312
1533404
TUBE AS
M312
M312
1223594
TUBE AS
M312
M312
1221198
TUBE AS
M312
M312
1221197
TUBE AS
M312
M312
1246969
TUBE AS
M312
M312
1246968
TUBE AS
M312
M312
1246967
TUBE AS
M312
M312
1356038
TUBE AS
M312
M312
1356037
TUBE AS
M312
M312
1242518
TUBE AS
M312
M312
1216048
TUBE AS
M312
M312
1242520
TUBE AS
M312
M312
1299966
TUBE AS
M312
M312