1223583 TUBE AS Caterpillar parts
M312
Rating:
Alternative (cross code) number:
CA1223583
122-3583
1223583
CA1223583
122-3583
1223583
WHEELED EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$175.24
19 Feb 2024
US: All Parts Whole
1223583 Drive Wheel Tire 8 1/2x2" Tennant Nobles AM SS5 T500 T5 B7 B5 T5e T500e
Sourcefy Made with the Highest Quality Components Available || 6 Months Unlimited Warranty || Pressure and Computer tested for consistent Quality and unsurpassed reliability || Machine Application - A5 Automatic Scrubber, A500 Walk-Behind Floor Scrubber, B5 Walk-Behind Battery Burnisher, Speed Scrub (24-32") Automatic Scrubber, Speed Scrub 500 Walk-Behind Floor Scrubber, SS500 Walk-Behind Floor Scrubber, SpeedGleam 5 Walk-Behind Battery Burnisher, SpeedGleam 7 Walk-Behind Battery Burnisher, SpeedGleam Walk-Behind Battery Burnisher, T5 Automatic Scrubber, T500 Walk-Behind Floor Scrubber, T500e Walk-Behind Floor Scrubber, T5e Automatic Scrubber; OD x Width - 8 1/2" x 2"
Sourcefy Made with the Highest Quality Components Available || 6 Months Unlimited Warranty || Pressure and Computer tested for consistent Quality and unsurpassed reliability || Machine Application - A5 Automatic Scrubber, A500 Walk-Behind Floor Scrubber, B5 Walk-Behind Battery Burnisher, Speed Scrub (24-32") Automatic Scrubber, Speed Scrub 500 Walk-Behind Floor Scrubber, SS500 Walk-Behind Floor Scrubber, SpeedGleam 5 Walk-Behind Battery Burnisher, SpeedGleam 7 Walk-Behind Battery Burnisher, SpeedGleam Walk-Behind Battery Burnisher, T5 Automatic Scrubber, T500 Walk-Behind Floor Scrubber, T500e Walk-Behind Floor Scrubber, T5e Automatic Scrubber; OD x Width - 8 1/2" x 2"
Compatible equipment models: 1223583:
Information:
Illustration 1 g02079684
Schematic of the +5 Volt Supply from the LH Operator ECMThis diagnostic code is associated with the 5 volt power supply from the LH Operator ECM. The 5 volt power supply provides power for the Left Propel Speed Dial.The CID 0262 FMI 03 diagnostic code is activated when the LH Operator ECM detects that the voltage of the 5 volt power supply circuit is higher than normal.Note: The LH Operator ECM is located under the LH Operator Platform.The following conditions could cause this diagnostic code:
The power supply circuit is shorted to a higher voltage source.
The ECM has failed. This situation is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the problem has been corrected. Verify that the CID 0262 FMI 03 is active before performing this procedure.System Response:Sensors connected to the supply will not log faults.Test Step 1. CHECK THE VOLTAGE AT THE COMPONENTS
Turn the disconnect switch and the key start switch to the ON position.
Disconnect the LH Operator ECM Harness connector from the components.
At the machine harness connector for the LP Propel Speed Dial, measure the voltage between supply contact A (wire 175-BK) to return contact B (wire C235-BK).Expected Result:The voltage measurement is 5.0 0.4 DCV.Results:
OK - The voltage measurement is 5.0 0.4 DCV. The voltage is correct. Proceed to Test Step 4.
NOT OK - The voltage measurement is greater than 5.0 0.4 DCV. The measurement is not correct. Proceed to Test Step 2.Test Step 2. CHECK THE POWER SUPPLY AT THE LH OPERATOR ECM
Turn the disconnect switch and the key start switch to the OFF position.
At LH Operator ECM connector J1, use a 151-6320 Removal Tool or a similar tool to remove the supply wire and socket at contact J1-11 (wire 175-BK) and the return wire and socket at contact J1-21 (wire C235-BK) from the connector. The LH Operator ECM Harness connector J1 remains connected to the ECM.
Turn the disconnect switch and the key switch to the ON position.
Use the multimeter probes in order to make contact on the LH Operator ECM connector pins. Measure the voltage at the ECM between the power supply contact J1-11 (wire 175-BK) and the return contact J1-21 (wire C235-BK).Expected Result:The voltage measurement is 5.0 0.4 DCV.Results:
OK - The voltage measurement is 5.0 0.4 DCV. The voltage is correct. The ECM power supply is correct. Turn the key start switch and the disconnect switch to the OFF position. Install the wires and sockets that were removed from the J1 connector back into the original locations. Proceed to Test
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
1193662
TUBE-HEAT SHRINK
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
1186693
TUBE AS
M312, M315, M318, M320
M312, M315, M318, M320
1496845
TUBE
M312, M315, M318
M312, M315, M318
1473785
TUBE AS
M312, M315
M312, M315
1293482
TUBE AS
M312, M315
M312, M315
1246980
TUBE AS
M312
M312
1223593
TUBE AS
M312
M312
1246968
TUBE AS
M312
M312
1242518
TUBE AS
M312
M312
1249569
TUBE
M312
M312
1532064
TUBE AS
M312
M312
1533404
TUBE AS
M312
M312
1250607
TUBE AS
M312
M312
1250606
TUBE AS
M312
M312
1254076
TUBE AS
M312
M312
1254075
TUBE AS
M312
M312
1223592
TUBE AS
M312
M312
1223590
TUBE AS
M312
M312
1246968
TUBE AS
M312
M312
1246967
TUBE AS
M312
M312
1246966
TUBE AS
M312
M312
1223586
TUBE AS
M312
M312
1223585
TUBE AS
M312
M312
1223584
TUBE AS
M312
M312