This diagnostic code is associated with the Starter Motor Relay. The FMI 03 means that the ECM has determined that the voltage of the relay circuit is above normal.The possible causes of the diagnostic code are listed:
The relay has failed.
The energize circuit of the relay is shorted to the +battery circuit.
The ECM has failed. The failure of the ECM is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the circuit are clean and secure. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0444 FMI 03 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE RELAY FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the relay and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-7 (wire P989-GN(Green)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-7 (P989-GN(Green)) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors in order to make sure that the connectors are fully seated. Also, make sure that the clips for each connector are fastened securely.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the diagnostic code is active. Expected Result:
Parts tube Caterpillar catalog:
3157303
TUBE AS
Caterpillar
Caterpillar
3157239
TUBE AS
Caterpillar
Caterpillar
3157230
TUBE AS
Caterpillar
Caterpillar
3157211
TUBE AS
Caterpillar
Caterpillar
3157203
TUBE AS
Caterpillar
Caterpillar
3157140
TUBE AS
Caterpillar
Caterpillar
3157305
TUBE AS
Caterpillar
Caterpillar
3157306
TUBE AS
Caterpillar
Caterpillar
3157332
TUBE AS
Caterpillar
Caterpillar
3157333
TUBE AS
Caterpillar
Caterpillar
3157334
TUBE AS
Caterpillar
Caterpillar
3157335
TUBE AS
Caterpillar
Caterpillar