3T0598 TUBE Caterpillar parts
517, 527, D5HTSK II, D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T LGPPAT, D6T XL
Rating:
Alternative (cross code) number:
CA3T0598
3T-0598
3T0598
CA3T0598
3T-0598
3T0598
Weight: 46 pounds 21 kg.
TRACK SKIDDER, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 3T0598 Tube Bearing for Heavy Equipment
CTP Tube Bearing Only || Sold in each || Easy in-and-out fit
CTP Tube Bearing Only || Sold in each || Easy in-and-out fit
CTP 3T0598 Tube Bearing for Heavy Equipment
CTP Tube Bearing Only || Sold in each || Easy in-and-out fit
CTP Tube Bearing Only || Sold in each || Easy in-and-out fit
Compatible equipment models: 3T0598:
Information:
Transmission, SPN 738 FMI 3Conditions Which Generate This Code:
Illustration 1 g01335076
Connections of the transmission clutch solenoid 5
This diagnostic code is associated with the transmission clutch solenoid 5. The FMI 3 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 738 FMI 3 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-15 to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-15 and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECM.The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the J2 connector for the ECM, use a wire removal tool to remove wire J834-PU(Purple) from contact J2-15.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active diagnostic code. Expected Result:The FMI 3 changes to an FMI 5 after the wire is disconnected.Results:
YES - The FMI 3 changes to a FMI 5 after the wire is disconnected. The ECM has responded correctly to the condition of an open circuit. Reinstall the disconnected wire to the correct space in the ECM connector before proceeding to the next Test Step. Proceed to Test Step 3.
NO - The FMI 3 remains active. The status of the active diagnostic code did not change when the wire was disconnected from the ECM.Repair: The ECM has not responded correctly to the condition of an open circuit. The operation of the ECM is not correct. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacing, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect
Illustration 1 g01335076
Connections of the transmission clutch solenoid 5
This diagnostic code is associated with the transmission clutch solenoid 5. The FMI 3 means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 738 FMI 3 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J2-15 to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-15 and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECM.The disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the J2 connector for the ECM, use a wire removal tool to remove wire J834-PU(Purple) from contact J2-15.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active diagnostic code. Expected Result:The FMI 3 changes to an FMI 5 after the wire is disconnected.Results:
YES - The FMI 3 changes to a FMI 5 after the wire is disconnected. The ECM has responded correctly to the condition of an open circuit. Reinstall the disconnected wire to the correct space in the ECM connector before proceeding to the next Test Step. Proceed to Test Step 3.
NO - The FMI 3 remains active. The status of the active diagnostic code did not change when the wire was disconnected from the ECM.Repair: The ECM has not responded correctly to the condition of an open circuit. The operation of the ECM is not correct. Prior to replacing an ECM, always contact your dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM requires replacing, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect
Cat SIS web machinery list:
Parts tube Caterpillar catalog:
4S8603
TUBE AS-SCREEN
14G, 16G, 24H, 3192, 515, 525, 525B, 611, 613C, 613C II, 613G, 615, 615C, 65, 69D, 7211, 7231, 7241, 7251, 7261, 7271, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F, 776, 777,...
14G, 16G, 24H, 3192, 515, 525, 525B, 611, 613C, 613C II, 613G, 615, 615C, 65, 69D, 7211, 7231, 7241, 7251, 7261, 7271, 769C, 769D, 771C, 771D, 773B, 773D, 773E, 773F, 775B, 775D, 775E, 775F, 776, 777,...
9Y7589
TUBE AS-SCAVENGE
120G, 130G, 3304, 3304B, 515, 517, 518, 518C, 525, 527, 936F, 950B, 963, CB-534, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G3304
120G, 130G, 3304, 3304B, 515, 517, 518, 518C, 525, 527, 936F, 950B, 963, CB-534, D4E, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G3304
4S8602
TUBE ASSEM.
613C II, 615C, 69D, 7271, 769C, 773B, 776, 777, 777B, 834B, 834G, 834H, 836G, 836H, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 960F, 966C, 966G, 966H, 966R, AD55, CX31-C9I, D400, D...
613C II, 615C, 69D, 7271, 769C, 773B, 776, 777, 777B, 834B, 834G, 834H, 836G, 836H, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 960F, 966C, 966G, 966H, 966R, AD55, CX31-C9I, D400, D...
7W1058
TUBE AS-SUPPLY
120G, 130G, 3304, 518C, 527, 936, 936F, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G936
120G, 130G, 3304, 518C, 527, 936, 936F, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G936
7W3042
TUBE AS-DRAIN
120G, 130G, 3304, 518C, 527, 936, 936F, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G936
120G, 130G, 3304, 518C, 527, 936, 936F, D4E SR, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II, G936
2633464
TUBE AS
627G, 627H, 627K LRC, 637D, 637E, 637G, 973C, 973D, C-9, C9, CX31-C9I, D6R, D6R II, D6R III, D6R STD, D6T, D7E, D7R XR, TH31-E61
627G, 627H, 627K LRC, 637D, 637E, 637G, 973C, 973D, C-9, C9, CX31-C9I, D6R, D6R II, D6R III, D6R STD, D6T, D7E, D7R XR, TH31-E61
7G4355
TUBE
225, D6H, D6H XL, D6H XR, D6R, D6R II, D6T LGP
225, D6H, D6H XL, D6H XR, D6R, D6R II, D6T LGP
3W7770
TUBE AS
D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II
D4H, D4H XL, D4HTSK II, D4HTSK III, D5H, D5H XL, D5HTSK II
4S6559
TUBE
D5, D5B, D5H, D5H XL, D5HTSK II, D6M
D5, D5B, D5H, D5H XL, D5HTSK II, D6M
2W6030
TUBE
D6H, D6H II, D6H XR
D6H, D6H II, D6H XR
3T5922
TUBE AS
D6H, D6H XL, D6H XR, D6R
D6H, D6H XL, D6H XR, D6R
1W1631
TUBE ASSEM.
515, 517, 950B, 963, G936
515, 517, 950B, 963, G936
3W5669
TUBE
D6H, D6R, D6R II, D6R III
D6H, D6R, D6R II, D6R III
3W6528
TUBE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D6R III, D6T
1703864
TUBE AS
D6R
D6R
1703863
TUBE AS
D6R
D6R
1703868
TUBE AS
D6R
D6R
1703867
TUBE AS
D6R
D6R
5S8714
TUBE AS
153, 163, 173B, 6A, D6D, D6E, D6E SR, D6G SR, D6G2 XL, D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D7R
153, 163, 173B, 6A, D6D, D6E, D6E SR, D6G SR, D6G2 XL, D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D7R
5S8718
TUBE AS
153, 163, 173B, 6A, D6D, D6E, D6E SR, D6G SR, D6G2 XL, D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D7R
153, 163, 173B, 6A, D6D, D6E, D6E SR, D6G SR, D6G2 XL, D6H, D6H II, D6H XL, D6H XR, D6R, D6R II, D7R
1123827
TUBE AS
D6R
D6R
1502984
TUBE AS
D6R
D6R
9U9161
TUBE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II
9U9162
TUBE AS
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II
D6H, D6H II, D6H XL, D6H XR, D6R, D6R II