Information:
Which Generate This Code:The mast zero position is out of tolerance.Note: This diagnostic code may be shown after a software version upgrade.Test Step 1. CHECK THE ELECTRIC MASTCheck for excessive end play in the electric mast tube.Expected Result:Maximum allowable movement is 0.76 mm (0.03 inch).Results:
OK - The maximum allowable movement is 0.76 mm (0.03 inch). Proceed to Test Step 2.
NOT OK - The end play of the mast is greater than 0.76 mm (0.03 inch).Repair: Repair the electric mast or replace the electric mast.STOPTest Step 2. CYCLE POWER TO THE SYSTEM
Run the electronic mast to the top and bottom positions for two complete cycles.
Move the "Power/Setup" Switch for the display to the "OFF" position.
Turn the key start switch for the machine to the "OFF" position.
Turn the key start switch for the machine to the "ON" position.
Move the "Power/Setup" Switch for the display to the "ON" position.Expected Result:The diagnostic code becomes inactive.Results:
YES - The diagnostic code becomes inactive. Return the machine to normal operation.STOP
NO - The diagnostic code is still active.Repair: Replace the circuit board assembly for the Electric Mast. Refer to Special Instruction, REHS2402, "AccuGrade Electric Mast Repair Instructions". Contact your Technical communicator for a possible consultation with Caterpillar.STOP
OK - The maximum allowable movement is 0.76 mm (0.03 inch). Proceed to Test Step 2.
NOT OK - The end play of the mast is greater than 0.76 mm (0.03 inch).Repair: Repair the electric mast or replace the electric mast.STOPTest Step 2. CYCLE POWER TO THE SYSTEM
Run the electronic mast to the top and bottom positions for two complete cycles.
Move the "Power/Setup" Switch for the display to the "OFF" position.
Turn the key start switch for the machine to the "OFF" position.
Turn the key start switch for the machine to the "ON" position.
Move the "Power/Setup" Switch for the display to the "ON" position.Expected Result:The diagnostic code becomes inactive.Results:
YES - The diagnostic code becomes inactive. Return the machine to normal operation.STOP
NO - The diagnostic code is still active.Repair: Replace the circuit board assembly for the Electric Mast. Refer to Special Instruction, REHS2402, "AccuGrade Electric Mast Repair Instructions". Contact your Technical communicator for a possible consultation with Caterpillar.STOP
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
4584246
TUBE AS
Caterpillar
Caterpillar
4584244
TUBE AS
Caterpillar
Caterpillar
4584236
TUBE AS
Caterpillar
Caterpillar
4584235
TUBE AS
Caterpillar
Caterpillar
4584213
TUBE AS
Caterpillar
Caterpillar
4568999
TUBE AS
Caterpillar
Caterpillar
4584249
TUBE AS
Caterpillar
Caterpillar
4584275
TUBE AS
Caterpillar
Caterpillar
4584291
TUBE AS
Caterpillar
Caterpillar
4584301
TUBE AS
Caterpillar
Caterpillar
4584302
TUBE AS
Caterpillar
Caterpillar
4584622
TUBE AS
Caterpillar
Caterpillar