Illustration 1 g00563641
Schematic of the RTD
Illustration 2 g00562911
Schematic of the RTDFunctional Test
Note: The 163-0096 Diagnostic and Calibration Tool can be used in order to troubleshoot this component. Refer to the "Owner's Manual" for more information.
Check the electrical connectors and check the wiring.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the power supply.
Check the electrical connectors and check the wiring for damage or bad connections.
Verify that all modules are properly seated.
Verify the status of the LED on the SLC 5/04 - 5/05.The results of the preceding procedure are in the following list:
All of the components are fully installed. All of the components are free of corrosion. All of the components are free of damage. All of the modules are properly seated. Proceed to 2.
The components are not fully installed. The components are not free of corrosion. The components are damaged. All of the modules are not properly seated. Repair the component. Verify that the repair resolves the problem. STOP.
Check the RTD.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Disconnect the RTD from the wiring harness. This is done by removing the connector head of the RTD.
Measure the resistance on the sensor. Measure the resistance between the following terminals: Terminal 1 and Terminal 2.
Use table 1 in order to determine if the RTD is functioning normally.
Table 1
RTD
Temperature and Resistance    
Temperature    Ohms    Difference per °C    
0 °C (32 °F)     100.00     0.39    
10 °C (50.0 °F)     103.90     0.39    
20 °C (68 °F)     107.79     0.39    
30 °C (86 °F)     111.67     0.39    
40 °C (104 °F)     115.54     0.39    
50 °C (122 °F)     119.40     0.39    
60 °C (140 °F)     123.24     0.38    
70 °C (158 °F)     127.07     0.38    
80 °C (176 °F)     130.89     0.38    
90 °C (194 °F)     134.70     0.38    
100 °C (212 °F)     138.50     0.38    
110 °C (230 °F)     142.29     0.38    
120 °C (248 °F)     146.06     0.38    
130 °C (266 °F)     149.82     0.37    
140 °C (284 °F)     153.58     0.37    
150 °C (302 °F)     157.31     0.37    The results of the preceding procedure are in the following list:
The resistance is correct. The RTD is functioning normally. Proceed to 3.
The resistance is not correct. The RTD is not functioning normally. Replace the RTD. Stop.
Measure the resistance of the interconnect wiring harness.
Connect the RTD to the wiring harness. This is done by connecting the connector head of the RTD.
Locate the RTD terminal and locate the sense terminal. The terminals are located in the control panel. The
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
4666843
TUBE AS
Caterpillar
Caterpillar
4666836
TUBE AS
Caterpillar
Caterpillar
4663199
TUBE AS
Caterpillar
Caterpillar
4663192
TUBE AS
Caterpillar
Caterpillar
4646005
TUBE
Caterpillar
Caterpillar
4646002
TUBE AS
Caterpillar
Caterpillar
4688274
TUBE AS
Caterpillar
Caterpillar
4688272
TUBE AS
Caterpillar
Caterpillar
4688271
TUBE AS
Caterpillar
Caterpillar
4683059
TUBE AS
Caterpillar
Caterpillar
4673418
TUBE AS
Caterpillar
Caterpillar
4666878
TUBE AS
Caterpillar
Caterpillar