Continuity Check of the Glow Plugs
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
4714261
TUBE AS
Caterpillar
Caterpillar
4707343
TUBE
Caterpillar
Caterpillar
4700948
TUBE AS
Caterpillar
Caterpillar
4700947
TUBE AS
Caterpillar
Caterpillar
4700946
TUBE AS
Caterpillar
Caterpillar
4700945
TUBE AS
Caterpillar
Caterpillar
4725044
TUBE
Caterpillar
Caterpillar
4725014
TUBE
Caterpillar
Caterpillar
4724949
TUBE
Caterpillar
Caterpillar
4724947
TUBE AS
Caterpillar
Caterpillar
4720688
TUBE AS
Caterpillar
Caterpillar
4714263
TUBE AS
Caterpillar
Caterpillar