MID 087 - Chassis ECMCID 2249 - Steering Accumulator Purge SolenoidFMI 05 - Current Below Normal
Illustration 1 g02749956
Steering accumulator purge solenoid circuit
This diagnostic code indicates the Chassis ECM detects steering accumulator purge solenoid current is below normal.The following can cause this code:
Open solenoid energizer circuit
Open solenoid return circuit
Failed solenoid
Failed ECMThe resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).System Response:
A Level 1 Warning occursNote: The following test procedure may create other diagnostic codes. Ignore these created codes and clear these created codes after the original diagnostic code has been corrected.Test Step 1. CHECK THE DIAGNOSTIC CODE
Turn off the keyswitch and the disconnect switch.
Inspect the harness. Clean the harness connector contacts.Inspect the harness connector contacts for corrosion or damage. Inspect the wire insulation for damage caused by heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each circuit wire.
Reconnect all harness connectors. Verify that the connectors are fully seated and the clips are fastened.
Check for intermittent problems. Using Cat® Electronic Technician (Cat ET), perform a wiggle test on the harness.
Turn on the disconnect switch and the keyswitch.
Operate the machine.
Check CID 2249 FMI 05 status. Expected Result:CID 2249 FMI 05 is not active.Results:
OK - CID 2249 FMI 05 is not active.Repair: The initial diagnostic code was probably caused by a poor connection at one of the connectors that was checked. Resume normal operation.STOP
NOT OK - CID 2249 FMI 05 is active. Proceed to Test Step 2.Test Step 2. CHECK THE SOLENOID
Disconnect the harness from the solenoid.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire U772-YL(Yellow)) to contact 2 (wire H868-WH(White)).
Turn on the disconnect switch and the keyswitch.
Observe the diagnostic code CID 2249 FMI 05 status. Expected Result:CID 2249 FMI 05 is no longer active. CID 2249 FMI 06 is active.Results:
OK - CID 2249 FMI 05 is no longer active. CID 2249 FMI 06 is active. The solenoid has failed.Repair: Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NOT OK - CID 2249 FMI 05 is active. The jumper wire does not affect the diagnostic code status. Proceed to Test Step 3.Test Step 3. CHECK FOR AN OPENThe jumper wire that was installed in the previous test step remains in place.
Turn off the keyswitch and the disconnect switch.
Disconnect the harness connectors from the Chassis ECM.
At the harness connector for the solenoid, place a jumper wire from contact 2 (wire H868-WH(White)) to contact 1 (wire U772-YL(Yellow)).
At the machine harness connectors for the ECM, measure the resistance from contact J2-6 (wire U772-WH(White)) to contact J2-8 (wire H868-WH(White)).
Check the resistance. Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. Proceed to Test Step 4.
NOT OK - The resistance is greater than 5.0 ohms. The harness is open. Repair: Repair or replace the harness.The open connection or the possible bad connection is in one of the following wires: U772-WH(White) and H868-WH(White).
A resistance greater than 5000 ohms indicates that a
Illustration 1 g02749956
Steering accumulator purge solenoid circuit
This diagnostic code indicates the Chassis ECM detects steering accumulator purge solenoid current is below normal.The following can cause this code:
Open solenoid energizer circuit
Open solenoid return circuit
Failed solenoid
Failed ECMThe resistance of the solenoid coil should be 27 1.4 ohms at 20 °C (68.0 °F).System Response:
A Level 1 Warning occursNote: The following test procedure may create other diagnostic codes. Ignore these created codes and clear these created codes after the original diagnostic code has been corrected.Test Step 1. CHECK THE DIAGNOSTIC CODE
Turn off the keyswitch and the disconnect switch.
Inspect the harness. Clean the harness connector contacts.Inspect the harness connector contacts for corrosion or damage. Inspect the wire insulation for damage caused by heat, corrosion, or chafing.
Perform a 45 N (10 lb) pull test on each circuit wire.
Reconnect all harness connectors. Verify that the connectors are fully seated and the clips are fastened.
Check for intermittent problems. Using Cat® Electronic Technician (Cat ET), perform a wiggle test on the harness.
Turn on the disconnect switch and the keyswitch.
Operate the machine.
Check CID 2249 FMI 05 status. Expected Result:CID 2249 FMI 05 is not active.Results:
OK - CID 2249 FMI 05 is not active.Repair: The initial diagnostic code was probably caused by a poor connection at one of the connectors that was checked. Resume normal operation.STOP
NOT OK - CID 2249 FMI 05 is active. Proceed to Test Step 2.Test Step 2. CHECK THE SOLENOID
Disconnect the harness from the solenoid.
At the machine harness connector for the solenoid, place a jumper wire from contact 1 (wire U772-YL(Yellow)) to contact 2 (wire H868-WH(White)).
Turn on the disconnect switch and the keyswitch.
Observe the diagnostic code CID 2249 FMI 05 status. Expected Result:CID 2249 FMI 05 is no longer active. CID 2249 FMI 06 is active.Results:
OK - CID 2249 FMI 05 is no longer active. CID 2249 FMI 06 is active. The solenoid has failed.Repair: Replace the solenoid. Verify that the new solenoid corrects the problem.STOP
NOT OK - CID 2249 FMI 05 is active. The jumper wire does not affect the diagnostic code status. Proceed to Test Step 3.Test Step 3. CHECK FOR AN OPENThe jumper wire that was installed in the previous test step remains in place.
Turn off the keyswitch and the disconnect switch.
Disconnect the harness connectors from the Chassis ECM.
At the harness connector for the solenoid, place a jumper wire from contact 2 (wire H868-WH(White)) to contact 1 (wire U772-YL(Yellow)).
At the machine harness connectors for the ECM, measure the resistance from contact J2-6 (wire U772-WH(White)) to contact J2-8 (wire H868-WH(White)).
Check the resistance. Expected Result:The resistance is less than 5.0 ohms.Results:
OK - The resistance is less than 5.0 ohms. Proceed to Test Step 4.
NOT OK - The resistance is greater than 5.0 ohms. The harness is open. Repair: Repair or replace the harness.The open connection or the possible bad connection is in one of the following wires: U772-WH(White) and H868-WH(White).
A resistance greater than 5000 ohms indicates that a
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
5P1198
TUBE
120B, 140B, 1673C, 1674, 225, 3054, 3056, 3192, 3304, 3306, 3406, 3408, 3408C, 3412, 518, 528, 561D, 571G, 572G, 583K, 594H, 627B, 631C, 641B, 650B, 7251, 7261, 768B, 769, 772, 773, 814, 824B, 834, 83...
120B, 140B, 1673C, 1674, 225, 3054, 3056, 3192, 3304, 3306, 3406, 3408, 3408C, 3412, 518, 528, 561D, 571G, 572G, 583K, 594H, 627B, 631C, 641B, 650B, 7251, 7261, 768B, 769, 772, 773, 814, 824B, 834, 83...
5P1201
TUBE
1674, 3304, 572G, 583K, 631C, 633C, 641B, 65, 650B, 657B, 666B, 772, 777, 824B, 826B, 834, 910, 916, 926, 931, 933, 933C, 939, 939C, 966C, 980B, 983B, 992, D346, D348, D349, D353C, D399, D7F, D7G, D8K...
1674, 3304, 572G, 583K, 631C, 633C, 641B, 65, 650B, 657B, 666B, 772, 777, 824B, 826B, 834, 910, 916, 926, 931, 933, 933C, 939, 939C, 966C, 980B, 983B, 992, D346, D348, D349, D353C, D399, D7F, D7G, D8K...
2N3362
TUBE ASSEM.
D379, D379B, D398, D398B, D399, G379, G398, G399
D379, D379B, D398, D398B, D399, G379, G398, G399
5P1200
TUBE 182.88 cm(72 in.)
120B, 12F, 140B, 215, 225, 3192, 3304, 518, 561C, 561D, 594H, 621B, 621E, 621F, 621G, 623B, 623E, 623F, 623G, 627B, 627E, 627F, 627G, 641B, 650B, 651E, 657E, 920, 930, 941, 950B, 950B/950E, 951B, 955K...
120B, 12F, 140B, 215, 225, 3192, 3304, 518, 561C, 561D, 594H, 621B, 621E, 621F, 621G, 623B, 623E, 623F, 623G, 627B, 627E, 627F, 627G, 641B, 650B, 651E, 657E, 920, 930, 941, 950B, 950B/950E, 951B, 955K...
3N3148
TUBE ASSEM.
D379, D379B, D398, D398B, D399, D5
D379, D379B, D398, D398B, D399, D5
6K8854
TUBE AS
966C, 966R, D379
966C, 966R, D379
6K8853
TUBE AS
966C, 966R, D379
966C, 966R, D379
6K8857
TUBE AS-FRONT-RH
814, 815, 966C, 966R, D379
814, 815, 966C, 966R, D379
6K8858
TUBE AS-FRONT-LH
814, 815, 966C, 966R, D379
814, 815, 966C, 966R, D379
7K3272
TUBE AS
814, 815, 966C, 966R, D379
814, 815, 966C, 966R, D379
7K3271
TUBE AS
814, 815, 966C, 966R, D379
814, 815, 966C, 966R, D379
7V2927
TUBE AS
815, 966C, 966R, D379
815, 966C, 966R, D379
5L1805
TUBE ASSEM.
D379, D379A, D398, G379
D379, D379A, D398, G379
5L2088
TUBE ASSEM.
D379, D379A, D398, G379
D379, D379A, D398, G379
5L4484
TUBE (VENT)
D379, D379A, D398, G379
D379, D379A, D398, G379
8L4252
TUBE ASSEM.
D398, D398A, G398
D398, D398A, G398
4L7949
TUBE ASSEM.
D379A, D398A
D379A, D398A
4L8137
TUBE ASSEM.
D379, D379A, D398, D398A, D399, G379, G398, G399
D379, D379A, D398, D398A, D399, G379, G398, G399
2F4444
TUBE
D315, D379A, D397D
D315, D379A, D397D
4L8228
TUBE (VENT)
D379, D379A, D398
D379, D379A, D398
1N7155
TUBE ASSEM.
D379A, D399
D379A, D399
6L2972
TUBE (INLET)
D379, D379A
D379, D379A
8L4253
TUBE ASSEM.
D379, D379A, G379
D379, D379A, G379
4L8646
TUBE ASSEM.
D379, D379A, D379B, G379
D379, D379A, D379B, G379