6S8038 TUBE ASSEM. Caterpillar parts
3P, D3B, D3C, D4B, D4C
Rating:
Alternative (cross code) number:
CA6S8038
6S-8038
6S8038
CA6S8038
6S-8038
6S8038
Weight: 0.100 pounds 0 kg.
BULLDOZER, TRACK-TYPE TRACTOR,
Information:
Which Generate This Code:This diagnostic code is designed to indicate a short circuit (high current) in either the solenoid or the wiring for the electronic unit injector for No. 6 cylinder.The Electronic Control Module (ECM) detects the following conditions:
A high current condition (short circuit) for each of five consecutive attempts to operate
Battery voltage above 9 volts for 2 secondsSystem Response:The ECM will log the diagnostic code. If equipped, the diagnostic lamp will flash.The engine will have low power and/or rough running.When the "Injector Cutout Test" is performed, a faulty electronic unit injector will indicate a low reading in comparison with the other electronic unit injectors.An electrical fault can prevent the electronic unit injector from operating. A short circuit in the wiring or the ECM that is unique to one electronic unit injector will prevent that individual electronic unit injector from operating. A short circuit in common wiring within the ECM can prevent the three electronic unit injectors that share that common wiring from operating.The ECM will continue to attempt to operate the electronic unit injector after the diagnostic code has been logged but a short circuit will prevent the operation of the electronic unit injector.Test Step 1. Perform the following diagnostic procedure: Injector Solenoid Circuit - TestResults:
OK - STOP
A high current condition (short circuit) for each of five consecutive attempts to operate
Battery voltage above 9 volts for 2 secondsSystem Response:The ECM will log the diagnostic code. If equipped, the diagnostic lamp will flash.The engine will have low power and/or rough running.When the "Injector Cutout Test" is performed, a faulty electronic unit injector will indicate a low reading in comparison with the other electronic unit injectors.An electrical fault can prevent the electronic unit injector from operating. A short circuit in the wiring or the ECM that is unique to one electronic unit injector will prevent that individual electronic unit injector from operating. A short circuit in common wiring within the ECM can prevent the three electronic unit injectors that share that common wiring from operating.The ECM will continue to attempt to operate the electronic unit injector after the diagnostic code has been logged but a short circuit will prevent the operation of the electronic unit injector.Test Step 1. Perform the following diagnostic procedure: Injector Solenoid Circuit - TestResults:
OK - STOP
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
5G1058
TUBE AS
D3B, D3C, D3C II, D3C III, D4B, D4C, D4C III, D5C III
D3B, D3C, D3C II, D3C III, D4B, D4C, D4C III, D5C III
8Y1656
TUBE AS
D3C, D3C II, D3C III, D4C, D4C III, D5C III
D3C, D3C II, D3C III, D4C, D4C III, D5C III
5G1053
TUBE AS
D3B, D3C, D3C II, D3C III, D4B, D4C, D4C III, D5C III
D3B, D3C, D3C II, D3C III, D4B, D4C, D4C III, D5C III
6S4704
TUBE ASSEM. (R.H.)
3P, D3B, D3C
3P, D3B, D3C
6S4642
TUBE ASSEM. (L.H.)
3P, D3B, D3C
3P, D3B, D3C
5G0659
TUBE
910, 931B, D3, D3C II, D4C, D5C
910, 931B, D3, D3C II, D4C, D5C
5G2688
TUBE ASSEM.
931B, D3B
931B, D3B
5G5772
TUBE ASSEM.
153, 931B, D3B, D5B
153, 931B, D3B, D5B
5G2111
TUBE ASSEM.
931B, D3B
931B, D3B
5G4584
TUBE AS
931B, D3B
931B, D3B
5G6055
TUBE AS
D3B
D3B
5G5774
TUBE AS
931B, D3B
931B, D3B
9J0660
TUBE ASSEM.
955K, 955L, 977K
955K, 955L, 977K
6P2200
TUBE ASSEM.
977K
977K