8R7438 TUBE AS Caterpillar parts
215D, 219D
Rating:
Alternative (cross code) number:
CA8R7438
8R-7438
8R7438
CA8R7438
8R-7438
8R7438
Weight: 10 pounds 4 kg.
EXCAVATOR,
Information:
the unit in a clean environment. Make sure that you comply with the following standards:
The area is free of dust.
Make sure that there is good air circulation around the unit.
Make sure that the wall can support the weight of the unit.
Make sure that the floor can support the weight of the unit (including the optional floor mounting kit).
Make sure that a radius of 914.40 mm (36.00 inch) is maintained for opening the door before installing the Generator Set Start Module.
Make sure that there is 914.40 mm (36.00 inch) of clearance in front of the unit.
Make sure that there are 152.40 mm (6.00 inch) of clearance on the unit's right side.
Make sure that there are 228.60 mm (9.00 inch) of clearance on the unit's left side. This clearance is needed for the entry of the cable and for the circulation of the air.
Make sure that both installations have no less than 304.80 mm (12.00 inch) clearance on top and 406.40 mm (16.00 inch) on the bottom.
Make sure that the units are bolted securely to the wall or to the floor. Mounting the unit to the floor requires an optional kit in order to make sure that the installation of the unit is safe and secure.
The area is free of dust.
Make sure that there is good air circulation around the unit.
Make sure that the wall can support the weight of the unit.
Make sure that the floor can support the weight of the unit (including the optional floor mounting kit).
Make sure that a radius of 914.40 mm (36.00 inch) is maintained for opening the door before installing the Generator Set Start Module.
Make sure that there is 914.40 mm (36.00 inch) of clearance in front of the unit.
Make sure that there are 152.40 mm (6.00 inch) of clearance on the unit's right side.
Make sure that there are 228.60 mm (9.00 inch) of clearance on the unit's left side. This clearance is needed for the entry of the cable and for the circulation of the air.
Make sure that both installations have no less than 304.80 mm (12.00 inch) clearance on top and 406.40 mm (16.00 inch) on the bottom.
Make sure that the units are bolted securely to the wall or to the floor. Mounting the unit to the floor requires an optional kit in order to make sure that the installation of the unit is safe and secure.
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
6C3419
TUBE AS
215D
215D
6C3420
TUBE AS
215D
215D
8R8581
TUBE AS
215D
215D
8R6596
TUBE AS
229D, 231D
229D, 231D
8R6594
TUBE AS
229D, 231D
229D, 231D
8R6595
TUBE AS
229D, 231D
229D, 231D
8R7216
TUBE AS
219D
219D
8R7214
TUBE AS
219D
219D
8R7212
TUBE AS
219D
219D
8R7217
TUBE AS
219D
219D
8R7215
TUBE AS
219D
219D
8R7437
TUBE AS
215D, 219D
215D, 219D