9C6284 TUBE AS Caterpillar parts
950B, 950B/950E
Rating:
Alternative (cross code) number:
CA9C6284
9C-6284
9C6284
CA9C6284
9C-6284
9C6284
Weight: 0.35 pounds 0 kg.
WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 9C6284 Tube Fittings for Models 950B/950B/950E
CTP For Models 950B/950B/950E || Highly Efficient || Easy in-and-out fit
CTP For Models 950B/950B/950E || Highly Efficient || Easy in-and-out fit
CTP 9C6284 Tube Fittings for Models 950B/950B/950E
CTP For Models 950B/950B/950E || Highly Efficient || Easy in-and-out fit
CTP For Models 950B/950B/950E || Highly Efficient || Easy in-and-out fit
Information:
Conditions Which Generate This Code:
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
"K1"     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1 can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0477 FMI 04 is an short circuit of the "K1" relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0477 FMI 04 is active.Note: The "DIAG" indicator will be flashing and the CID 0477 FMI 04 will be present on the display if the
Illustration 1 g00722721
Rear view of the PRCM (1) 40-pin connector (2) Relay module
Table 1
Load Specifications For the Internal Relays of the PRCM    
Relay Module and Number     Ratings For Resistive Loads     Ratings For Inductive Loads    
"K1"     7 milliamperes to 1 Amperes (24 DCV)     None (1) (2) (3)    
"K2", "K3", "K4", "K5" (terminal 24), "K6" and "K7"     0.5 to 10 amperes (24 DCV)     0.5 to 10 Amperes (24 DCV) (3)    
"K5" (terminals 23 and 36)     0.5 to 10 Amperes (24 DCV) and 0.5 to 10 Amperes (24 ACV)     0.5 to 5 Amperes (24 DCV) and 0.5 to 7.5 Amperes (110 ACV)    
( 1 ) Do NOT connect inductive loads to these terminals.
( 2 ) The contacts of the relay that is connected to terminals 13 and 14 are gold flashed. The gold socket contact provides a source of low impedance for a low current resistive load. Loads that draw higher currents, currents that are of similar levels as terminals 23 and 36 in table 1 can be applied. However, if heavier loads are applied, the gold flashing will be permanently burned. This will eliminate the gold flashing from the contacts. This does not result in damage to the relay contacts, but the contacts can no longer be used for low current loads.
( 3 ) "K1" (terminals 13 and 14) is not fused.
Illustration 2 g00709866
The Connections for the PRCM to the Relay ModuleThe PRCM provides the internal relay outputs for customer's use. All relays are located in the relay module on the rear of the PRCM. If the CAT data link fails, the relay remains in the state required by the last valid input state. The relay may also be programmed to reset to the OFF position. Refer to Systems Operation, "Setpoint Viewing and Programming".The Possible cause of a CID 0477 FMI 04 is an short circuit of the "K1" relay coil. Clear the diagnostic code from the fault log when the troubleshooting procedure is completed.
Do not apply AC voltages to any relay module terminal other than terminals 23 and 36 of K5 and terminals 13 and 14 of K1 or permanent damage to the relay module will result. All other terminals have flyback diodes connected to them that increase relay life when driving inductive loads; however, this limits their use to DC voltages.
Note: All 3K-8782 Fuses ("AGC-10") in the relay module are rated at 10 Amperes DCV. Test Step 1. CHECK THE STATUS OF THE DIAGNOSTIC CODE.
Turn the ECS to the OFF/RESET position and then turn the ECS to the STOP position.
Press the "MODE" key until the diagnostic code viewing/clearing menu appears.
Observe the upper display. Check that the CID 0477 FMI 04 is active.Note: The "DIAG" indicator will be flashing and the CID 0477 FMI 04 will be present on the display if the
Caterpillar parts catalog:
Parts tube Caterpillar catalog:
2P2697
TUBE AS-AIR VENT
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215, 235B, 3304, 3304B, 3306, 3306B, 515, 518C, 525, 545, 572G, 572R, 615C...
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 215, 235B, 3304, 3304B, 3306, 3306B, 515, 518C, 525, 545, 572G, 572R, 615C...
8N7318
TUBE AS
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
8N7315
TUBE AS-OUTLET
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
120B, 120G, 12G, 12H, 12H ES, 12H NA, 130G, 140B, 140G, 140H, 140H ES, 140H NA, 143H, 14G, 14H NA, 160G, 160H, 160H ES, 160H NA, 163H NA, 1673C, 235, 235B, 330, 330 L, 3304, 3304B, 3306, 3306B, 3306C,...
4S8602
TUBE ASSEM.
613C II, 615C, 69D, 7271, 769C, 773B, 776, 777, 777B, 834B, 834G, 834H, 836G, 836H, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 960F, 966C, 966G, 966H, 966R, AD55, CX31-C9I, D400, D...
613C II, 615C, 69D, 7271, 769C, 773B, 776, 777, 777B, 834B, 834G, 834H, 836G, 836H, 936, 936F, 950, 950B, 950B/950E, 950F, 950F II, 950G, 950G II, 960F, 966C, 966G, 966H, 966R, AD55, CX31-C9I, D400, D...
1W1631
TUBE ASSEM.
515, 517, 950B, 963, G936
515, 517, 950B, 963, G936
8N1965
TUBE-DISPOSAL
815B, 930, 950B, 966D, 966F, 966F II, 970F, 972G, D7H
815B, 930, 950B, 966D, 966F, 966F II, 970F, 972G, D7H
2V7990
TUBE AS
814B, 815B, 826C, 916, 926, 936, 936F, 950B, 950F, 950F II, 966D, 966F, 980C, 980F, CS-643, G936, IT18, IT18B, IT28, IT28B
814B, 815B, 826C, 916, 926, 936, 936F, 950B, 950F, 950F II, 966D, 966F, 980C, 980F, CS-643, G936, IT18, IT18B, IT28, IT28B
7W9553
TUBE AS-OUTLET
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H NA, 518C, 528B, 530B, 936, 936F, 950B, 950B/950E
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H NA, 518C, 528B, 530B, 936, 936F, 950B, 950B/950E
7G8141
TUBE AS
936, 936F, 950B, 950B/950E, 950F, 950F II, 966C, G936
936, 936F, 950B, 950B/950E, 950F, 950F II, 966C, G936
7E6796
TUBE AS
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H NA, 518C, 528B, 530B, 936, 936F, 950B/950E
120G, 12G, 12H, 12H ES, 12H NA, 130G, 140G, 140H, 140H ES, 140H NA, 143H, 160G, 160H, 160H ES, 160H NA, 163H NA, 518C, 528B, 530B, 936, 936F, 950B/950E
8N5292
TUBE
950B
950B
9C6281
TUBE AS
950B, 950B/950E
950B, 950B/950E
9C6283
TUBE AS
950B, 950B/950E
950B, 950B/950E
9C6296
TUBE AS
950B, 950B/950E
950B, 950B/950E
9C6282
TUBE AS
950B, 950B/950E
950B, 950B/950E
9C6281
TUBE AS
950B, 950B/950E
950B, 950B/950E
2Y8529
TUBE AS
966C, 966R
966C, 966R
7V7466
TUBE AS
966R
966R
3T6644
TUBE AS
966R
966R
3T6643
TUBE AS
966R
966R
3T6645
TUBE AS
966R
966R
3T6646
TUBE AS
966R
966R
7T6010
TUBE AS
966R
966R
7W3044
TUBE AS-DRAIN
950B
950B