1T0662 TURBINE Caterpillar parts
621, 621B, 621E, 621F, 621G, 621H, 621K, 623, 623E, 623F, 623G, 623H, 623K, 623K LRC, 627, 627B, 627E, 627F, 627G, 627H, 627K, 627K LRC, 631C, 631E, 631G, 633E II, 637, 637D, 637E, 637G, 657B, 657E, 6...
Rating:
Alternative (cross code) number:
CA1T0662
1T-0662
1T0662
CA1T0662
1T-0662
1T0662
Weight: 11 pounds 5 kg.
LOAD HAUL DUMP, WHEEL TRACTOR-SCRAPER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$347.98
22 Mar 2024
US: Fast 404
1T0662 Turbine-Conv Fits CATERPILLARR Models 1T0662
MAXCBD Part Number: 1T0662
MAXCBD Part Number: 1T0662
$277.68
17 Jan 2022
US: Florida-Parts-Z
1T0662 - Turbine-Converter 1T662 fit Caterpillar (CAT)
FIRST PRICE PARTS
FIRST PRICE PARTS
Compatible equipment models: 1T0662:
Information:
Check the exciter armature. Ensure that the rotating rectifier is tight. If a failure of a rectifier is suspected, proceed to the "Testing a Three-Diode Rectifier Block" section.Testing a Kato Rectifier
Disconnect leads on three standard diodes and three reverse diodes.
Run standard diode checks on diodes while leads are disconnected.
Verify minimum resistance of 15000 between varistor terminals.Testing a Three-Diode Rectifier Block
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.Note: A shorted diode can damage the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000.
Disconnect leads on three standard diodes and three reverse diodes.
Run standard diode checks on diodes while leads are disconnected.
Verify minimum resistance of 15000 between varistor terminals.Testing a Three-Diode Rectifier Block
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.Note: A shorted diode can damage the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000.
Cat SIS web machinery list:
Parts turbine Caterpillar catalog:
8N0820
TURBINE (housing)
245, 621B, 980C, 983B
245, 621B, 980C, 983B
1T0862
TURBINE
631E, 637E, 637G, 824C, 826C, 983, 983B, R2900, R2900G
631E, 637E, 637G, 824C, 826C, 983, 983B, R2900, R2900G
1T0792
TURBINE
24M, 657B, 735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G LRC, 775G OEM, 834
24M, 657B, 735, 735B, 740, 740B, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773B, 773D, 773E, 773F, 773G LRC, 773G OEM, 775B, 775D, 775E, 775F, 775G LRC, 775G OEM, 834
3095019
TURBINE AS
R1700G
R1700G
1T1805
TURBINE-CONVERTER
515, 561M, 561N, 924F, 928F, 928G, 938F, 938G, D5M, D5N, IT18F, IT24F, IT28F, IT28G, IT38F, IT38G
515, 561M, 561N, 924F, 928F, 928G, 938F, 938G, D5M, D5N, IT18F, IT24F, IT28F, IT28G, IT38F, IT38G
6Y3149
TURBINE-CONVERTER
613G, 938G II, 938H, 950F II, 950G, 950G II, 950H, 962G, 962G II, 962H, D5R LGP, D6M, D6N, D6N LGP, D6N OEM, IT38G II, IT38H, IT62G, IT62G II, IT62H, R1300, R1300G, R1300G II
613G, 938G II, 938H, 950F II, 950G, 950G II, 950H, 962G, 962G II, 962H, D5R LGP, D6M, D6N, D6N LGP, D6N OEM, IT38G II, IT38H, IT62G, IT62G II, IT62H, R1300, R1300G, R1300G II
7T4752
TURBINE-CONVERTER
527, D5H, D5H XL, D5HTSK II
527, D5H, D5H XL, D5HTSK II
8P9265
TURBINE-CONVERTER
589, D10N, D10R, D8L, D9L, D9R
589, D10N, D10R, D8L, D9L, D9R
1P2466
TURBINE ASSEM.
235, 641B, 650B, 657B, 666B, 772, 773, 992
235, 641B, 650B, 657B, 666B, 772, 773, 992
1T0782
TURBINE-CONVERTER
24H, 24M, 641B, 651E, 657B, 657E, 657G, 69D, 769C, 769D, 771C, 771D, 824B, 988F II, 992, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, D350E, D350E II, D35HP, D400, D400E, D400E II, D40D
24H, 24M, 641B, 651E, 657B, 657E, 657G, 69D, 769C, 769D, 771C, 771D, 824B, 988F II, 992, AD40, AD45, AD45B, AD55, AD55B, AD60, AE40, AE40 II, D350E, D350E II, D35HP, D400, D400E, D400E II, D40D
1T1287
TURBINE-CONVERTER
641B, 651E, 657E, 769C, 992
641B, 651E, 657E, 769C, 992
1T1480
TURBINE ASSEM.
816, 950B, 950B/950E, 955K, 955L
816, 950B, 950B/950E, 955K, 955L
1T0862
TURBINE
631E, 637E, 637G, 824C, 826C, 983, 983B, R2900, R2900G
631E, 637E, 637G, 824C, 826C, 983, 983B, R2900, R2900G
1T0723
TURBINE ASSEM.
816, 955K, 955L
816, 955K, 955L