20R2739 TURBO GP-BASIC Caterpillar parts
Rating:
Alternative (cross code) number:
CA20R2739
20R-2739
20R2739
CA20R2739
20R-2739
20R2739
Weight: 102 pounds 46 kg.
Related part:
3940379
TURBO GP-BASIC
20R2739
R
Information:
New Calibration Procedure to Check Reading Accuracy of the 1P3060 Pyrometer Group:
Only use the calibration circuit and information that follows to check the pyrometer reading accuracy:
CIRCUIT CONDITIONS1. All resistors are 1/4 watt, 20%.2. Digital voltmeter (DVM) has a maximum resolution of 100 microvolts (10 microvolts minimum) and not less than 0.1% accuracy.3. 12 VDC can be a 12 volt automotive battery or a bench power supply.4. R1 is a carbon potentiometer (volume control). The circuit does not have to be exact, but the voltage produced (made) across the resistance must be known.The input power (12 VDC) is decreased to millivolts when sent across the three parallel resistors. This is similar to a thermocouple output with 3.33 ohms resistance. The potentiometer (R1) is adjusted until the digital voltmeter (DVM) reads each of the values in the chart that follows. The pyrometer must read the temperature opposite, within 16°F.
If a bench power supply is used, the potentiometer (R1) can be zero ohms and the power supply voltage can be adjusted to give the necessary calibration voltages.
New calibrator circuit.
Only use the calibration circuit and information that follows to check the pyrometer reading accuracy:
CIRCUIT CONDITIONS1. All resistors are 1/4 watt, 20%.2. Digital voltmeter (DVM) has a maximum resolution of 100 microvolts (10 microvolts minimum) and not less than 0.1% accuracy.3. 12 VDC can be a 12 volt automotive battery or a bench power supply.4. R1 is a carbon potentiometer (volume control). The circuit does not have to be exact, but the voltage produced (made) across the resistance must be known.The input power (12 VDC) is decreased to millivolts when sent across the three parallel resistors. This is similar to a thermocouple output with 3.33 ohms resistance. The potentiometer (R1) is adjusted until the digital voltmeter (DVM) reads each of the values in the chart that follows. The pyrometer must read the temperature opposite, within 16°F.
If a bench power supply is used, the potentiometer (R1) can be zero ohms and the power supply voltage can be adjusted to give the necessary calibration voltages.
New calibrator circuit.
Parts turbo Caterpillar catalog:
20R2738
TURBO GP-BASIC
Caterpillar
Caterpillar
20R2742
TURBO GP-BASIC
Caterpillar
Caterpillar
20R3987
TURBO GP-BASIC
Caterpillar
Caterpillar
20R5216
TURBO GP-BASIC
Caterpillar
Caterpillar
20R7011
TURBO GP-BASIC
Caterpillar
Caterpillar
20R3000
TURBO GP-BASIC
Caterpillar
Caterpillar
20R6576
TURBO GP-BASIC
Caterpillar
Caterpillar
20R3769
TURBO GP-BASIC
Caterpillar
Caterpillar
20R7007
TURBO GP-BASIC
Caterpillar
Caterpillar
20R2741
TURBO GP-BASIC
Caterpillar
Caterpillar
20R2740
TURBO GP-BASIC
Caterpillar
Caterpillar
20R2743
TURBO GP-BASIC
Caterpillar
Caterpillar