1431209 TURBOCHARGER GP Caterpillar parts
3116
Rating:
Alternative (cross code) number:
CA1431209
143-1209
1431209
CA1431209
143-1209
1431209
Weight: 36 pounds 16 kg.
INDUSTRIAL ENGINE, MARINE ENGINE,
Related part:
1431209
TURBO GP-BASIC
0R7212
R
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
MovYard Turbo S300W049 Turbocharger 157-4386 1574386 10R-9769 10R9769 1431209 143-1209 1458884 145-8884 Fits for Caterpillar Engine 3116
MovYard Product type: Turbocharger for Cat Engine || Part Number: 170001, 179588, 0R7122, 0R7212, 10R9769, 127-7077, 1277077, 143-1209, 1431209, 145-8884, 1458884, 157-4386, 1574386 || Condition: 100%new; aftermarket || Application: Turbocharger for Caterpillar Engine 3116, Turbocharger for 3116 Industrial Engine || Turbocharger for Industrial Engine 4PG00001-UP, Turbocharger for Industrial Engine 2WG00001-UP, Turbocharger for Industrial Engine 4KG00001-UP, Turbocharger for Industrial Engine 1SK00001-UP, Turbocharger for Industrial Engine 2WG00001-UP
MovYard Product type: Turbocharger for Cat Engine || Part Number: 170001, 179588, 0R7122, 0R7212, 10R9769, 127-7077, 1277077, 143-1209, 1431209, 145-8884, 1458884, 157-4386, 1574386 || Condition: 100%new; aftermarket || Application: Turbocharger for Caterpillar Engine 3116, Turbocharger for 3116 Industrial Engine || Turbocharger for Industrial Engine 4PG00001-UP, Turbocharger for Industrial Engine 2WG00001-UP, Turbocharger for Industrial Engine 4KG00001-UP, Turbocharger for Industrial Engine 1SK00001-UP, Turbocharger for Industrial Engine 2WG00001-UP
New 170001 168465 168465R 169489 169489R 169603 169603R 170001R 0R7122 0R7212 10R9769 1277077 1431209 1458884 1574386 Turbo S300W049 For Caterpillar Genset, Marine Searay Sundancer (3116 3126 Engine)
Generic Part Number 170001 Previous Version 168465 168465R 169489 169489R 169603 169603R 170001 170001R 179588 179588R 468465 469489 469603 470001 479588 OE number 0R7122 0R7212 10R9769 127-7077 1277077 143-1209 1431209 145-8884 1458884 157-4386 1574386 Description For Genset Marine Searay Superabundance CHRA 170002 (0R7269 158-4645 1584645 170002R 178176 478176) Turbo Model S300W049 Prefix 1SK 2WG 4KG 4PG 9ZR CKK 4FM 9BM KW 300 HP RPM 2000 Fuel Diesel || Engine Marine, industrial 3116 3126 HEUI S/N 1SK2248-UP 1SK00001-UP 2WG6416-UP 4KG8041-9870 1SK2248-UP 4PG784-1890 4PG1891-3047 4PG3048-3492 4PG3048-3492 4PG4527-UP 2WG1660-3182 2WG3183-4162 2WG4163-5871 2WG5872-6114 2WG6115-6229 Angle (compressor housing) 307° Angle (turbine housing) 132° Bearing Housing 169207 (Oil Cooled) Turbine Wheel 169039 (156-0514 1560514)(Ind. 74.24 mm Exd. 64.59 mm 11 Blades) Comp. Wheel 170030 Back plate 167543 (1253300300) || Heat shield Number 167550 (3519302)(1649415)(1152301340) Repair Kit 318394 (169636 169032)(1253300750) Turbine Housing (Water Cooled) 169451 (135-2648) Comp. Housing 170029 (171604)(1920953) Turbine Housing AR 0.7 Gasket Kit 318418 Plug-Cup 4K0149 || Applications 1996-12 For Caterpillar Genset, Marine, Searay Sundancer With 3116, 3126 HEUI Engine
Generic Part Number 170001 Previous Version 168465 168465R 169489 169489R 169603 169603R 170001 170001R 179588 179588R 468465 469489 469603 470001 479588 OE number 0R7122 0R7212 10R9769 127-7077 1277077 143-1209 1431209 145-8884 1458884 157-4386 1574386 Description For Genset Marine Searay Superabundance CHRA 170002 (0R7269 158-4645 1584645 170002R 178176 478176) Turbo Model S300W049 Prefix 1SK 2WG 4KG 4PG 9ZR CKK 4FM 9BM KW 300 HP RPM 2000 Fuel Diesel || Engine Marine, industrial 3116 3126 HEUI S/N 1SK2248-UP 1SK00001-UP 2WG6416-UP 4KG8041-9870 1SK2248-UP 4PG784-1890 4PG1891-3047 4PG3048-3492 4PG3048-3492 4PG4527-UP 2WG1660-3182 2WG3183-4162 2WG4163-5871 2WG5872-6114 2WG6115-6229 Angle (compressor housing) 307° Angle (turbine housing) 132° Bearing Housing 169207 (Oil Cooled) Turbine Wheel 169039 (156-0514 1560514)(Ind. 74.24 mm Exd. 64.59 mm 11 Blades) Comp. Wheel 170030 Back plate 167543 (1253300300) || Heat shield Number 167550 (3519302)(1649415)(1152301340) Repair Kit 318394 (169636 169032)(1253300750) Turbine Housing (Water Cooled) 169451 (135-2648) Comp. Housing 170029 (171604)(1920953) Turbine Housing AR 0.7 Gasket Kit 318418 Plug-Cup 4K0149 || Applications 1996-12 For Caterpillar Genset, Marine, Searay Sundancer With 3116, 3126 HEUI Engine
Zachager 1PCS 157-4386 10R-9769 143-1209 145-8884 Turbocharger Turbo S300W049 Fits for Caterpillar Engine 3116
Zachager 【Part Number】157-4386 1574386 10R-9769 10R9769 1431209 143-1209 1458884 145-8884 || 【Application】 For Caterpillar CAT Engine 3116T 110HP Compactor CP-563D CS-563D CS-573D CS-583D || 【Improve power】Increase engine air intake, improve combustion efficiency and power output || 【Reduced emissions】 Helps reduce harmful emissions by improving combustion efficiency || 【Warm Tips】Please check the specifications carefully to make sure you get the product you want. If you are not sure, you can send us your model number.
Zachager 【Part Number】157-4386 1574386 10R-9769 10R9769 1431209 143-1209 1458884 145-8884 || 【Application】 For Caterpillar CAT Engine 3116T 110HP Compactor CP-563D CS-563D CS-573D CS-583D || 【Improve power】Increase engine air intake, improve combustion efficiency and power output || 【Reduced emissions】 Helps reduce harmful emissions by improving combustion efficiency || 【Warm Tips】Please check the specifications carefully to make sure you get the product you want. If you are not sure, you can send us your model number.
Compatible equipment models: 1431209:
Information:
All Caterpillar Generator SetsReference: Service Magazine; July 12, 1993; Page 10; "Preventive Maintenance To Reduce Risk Of Stator Failure"Reference: SEHS9124-01; Special Instruction; "Cleaning and Drying of Electric Set Generators"It is important that electric set generators are stored properly as problems can develop in the generator windings under certain environmental conditions. Most of these problems can be avoided by recognizing the effects of the environment on winding insulation and following protective measures throughout the storage period. Therefore, when a new generator arrives on site it should be protected from collective contaminants and moisture until installation.
Contaminants and moisture that are allowed to collect in the generator during the storage period may be harmful to the generator windings. Collective contaminants such as dirt, dust, grease, oil films, salt, and chemicals increase the risk of moisture collecting in the windings. Moisture can provide a conductive pathway between the bundles of wire. When this occurs, current will leak from the higher voltage bundle to the lower voltage bundle. The current leak produces heat and causes a breakdown and charring of the winding insulation. If the problem goes undetected, the windings may be severely damaged.
Since collective contaminants and moisture may damage generator windings, the generator set should be protected throughout any storage period.
The generator should be stored inside in a dry storage area where possible or covered with a plastic cover or similar type of protective cloth to guard against collective contaminants. The protective cover should extend to the ground, but remain loose to allow the generator to properly breathe. Also apply some type of rust preventative to unpainted parts if a long storage period is anticipated.
In addition, Caterpillar recommends maintaining the insulated parts and the air surrounding them at a temperature of at least 5 ° C (9 ° F) higher than the room temperature in which the equipment is located. This procedure helps to minimize moisture condensation.
Normal methods of providing the heat required are:
1. Space heaters2. Warm air blower. Do not exceed 206.7 kPa (30 psi). 3. Light bulb (60 Watt minimum) installed inside the generator in proximity to the stator core at the lowest possible location.Before placing the generator in storage, it is necessary that a megger insulation resistance check be performed and the results recorded. Refer to Service Magazine; July 12, 1993; Page 10; "Preventive Maintenance To Reduce Risk Of Stator Failure" for the Recommended Megger Insulation Test Procedure. The temperature and level of humidity should also be recorded. This check will provide a baseline for future reference.
It is important that this baseline be established when the unit is dry.Throughout the storage period, it is recommended that the shaft be rotated ten revolutions every 60 days. This procedure helps to insure that grease continues to cover all bearing surfaces.
Before removing a generator from storage and beginning the startup procedure, visually inspect the generator for any foreign material such as rodents, etc. that may have nested in the generator.
Perform another megger insulation resistance check, and compare this new reading to
Contaminants and moisture that are allowed to collect in the generator during the storage period may be harmful to the generator windings. Collective contaminants such as dirt, dust, grease, oil films, salt, and chemicals increase the risk of moisture collecting in the windings. Moisture can provide a conductive pathway between the bundles of wire. When this occurs, current will leak from the higher voltage bundle to the lower voltage bundle. The current leak produces heat and causes a breakdown and charring of the winding insulation. If the problem goes undetected, the windings may be severely damaged.
Since collective contaminants and moisture may damage generator windings, the generator set should be protected throughout any storage period.
The generator should be stored inside in a dry storage area where possible or covered with a plastic cover or similar type of protective cloth to guard against collective contaminants. The protective cover should extend to the ground, but remain loose to allow the generator to properly breathe. Also apply some type of rust preventative to unpainted parts if a long storage period is anticipated.
In addition, Caterpillar recommends maintaining the insulated parts and the air surrounding them at a temperature of at least 5 ° C (9 ° F) higher than the room temperature in which the equipment is located. This procedure helps to minimize moisture condensation.
Normal methods of providing the heat required are:
1. Space heaters2. Warm air blower. Do not exceed 206.7 kPa (30 psi). 3. Light bulb (60 Watt minimum) installed inside the generator in proximity to the stator core at the lowest possible location.Before placing the generator in storage, it is necessary that a megger insulation resistance check be performed and the results recorded. Refer to Service Magazine; July 12, 1993; Page 10; "Preventive Maintenance To Reduce Risk Of Stator Failure" for the Recommended Megger Insulation Test Procedure. The temperature and level of humidity should also be recorded. This check will provide a baseline for future reference.
It is important that this baseline be established when the unit is dry.Throughout the storage period, it is recommended that the shaft be rotated ten revolutions every 60 days. This procedure helps to insure that grease continues to cover all bearing surfaces.
Before removing a generator from storage and beginning the startup procedure, visually inspect the generator for any foreign material such as rodents, etc. that may have nested in the generator.
Perform another megger insulation resistance check, and compare this new reading to
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
2183181
TURBOCHARGER GP
G3516C
G3516C
4N6858
TURBOCHARGER GP
120G, 130G, 225, 3304, 518, 950, D4D
120G, 130G, 225, 3304, 518, 950, D4D
2714979
TURBOCHARGER GP
C175-16
C175-16
3318936
TURBOCHARGER GP
924H, 924HZ, 928H, 928HZ, C6.6
924H, 924HZ, 928H, 928HZ, C6.6
2848280
TURBOCHARGER GP
3608, 3616, C280-16, C280-8
3608, 3616, C280-16, C280-8
1269220
TURBOCHARGER GP
3406E, 3456
3406E, 3456
1457984
TURBOCHARGER GP
3512B, 3516B
3512B, 3516B
1418274
TURBOCHARGER GP
CB-634C, CB-634D, CS-563C, CS-563D, CS-573C, CS-583C, CS-583D
CB-634C, CB-634D, CS-563C, CS-563D, CS-573C, CS-583C, CS-583D
7C7687
TURBOCHARGER GP
3406B
3406B
2627099
TURBOCHARGER GP
824H, 825H, 826H
824H, 825H, 826H
4W2445
TURBOCHARGER GP
3406B
3406B