AVSPARE.COM
parts catalog

TURBOCHARGER GP 2432567 - Caterpillar


2432567 TURBOCHARGER GP Caterpillar parts 3412E, C18
Rating:
82
Alternative (cross code) number:
CA2432567
243-2567
2432567
Caterpillar 2432567 TURBOCHARGER GP
Weight: 83 pounds 37 kg.

Buy TURBOCHARGER GP 2432567 Caterpillar genuine, new aftermarket tractor parts with delivery
GENERATOR SET, MARINE ENGINE,

Related part:
2432567  TURBO GP-BASIC  10R2313  R

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$14.79
 

30 Sep 2019

-: -
Gimax UN 22.4305 22.4x30x5 24325/6/7 24x32x5/6/7 TPU Hydraulic Rotary Shaft Piston Rod Grooved U Lip O Ring Gasket Wiper Oil Seal - (Size: 9Pieces 22.4x30x5)
Size: 9Pieces 22.4x30x5 || Material: Rubber || Model number: 22.4x30x5 24x32x5/6/7 || Shape: Grooved Gasket || Standard or nonstandard: Standard
Number on catalog scheme: 2
  For full view, you need register

Compatible equipment models: 2432567:

GENERATOR SET  C18  
MARINE ENGINE  3412E   C18   Caterpillar

Information:


Illustration 1 g02027594
Schematic of the "Variable Relief Valve #2 Pressure" Solenoid
This diagnostic code is associated with the "Variable Relief Valve #2 Pressure" Solenoid. The FMI 03 means that the Machine ECM has determined that the voltage is above normal.The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The solenoid energizer circuit of the modulating valve is shorted to the +battery circuit.
The Machine ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 1666 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:When this diagnostic code is active, the Machine ECM will turn off the current to the failed solenoid.Test Step 1. CHECK THE SOLENOID ENERGIZER CIRCUIT FOR A SHORT TO THE +BATTERY CIRCUIT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the Machine ECM.
At the machine harness connector for the Machine ECM, measure the resistance from contact J2-28 (wire K865-PU(Purple)) to all contacts that are used in the machine harness connectors for the Machine ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-28 (K865-PU(Purple)) and the circuit that has a low resistance measurement.Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE
Inspect the contacts of the harness connectors. Clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 1666 FMI 03 diagnostic code is active. Expected Result:The CID 1666 FMI 03 diagnostic code is active.Results:
YES - The CID 1666 FMI 03 diagnostic code is active. The problem has not been corrected. The Machine ECM may have failed.Repair: It is unlikely that the Machine ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 1666 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP

Caterpillar parts catalog:

Caterpillar parts catalog
C18 Marine Generator Set SSM00001-UP
3412E Marine Engine 9KS00001-UP
C18 Marine Engine GES00001-UP
C18 Marine Generator Set JHL00001-UP
C18 Marine SCAC Generator Set DTP00001-UP
C18 Marine Auxiliary Generator Set GBM00001-UP POWERED BY C18 Engine
C18 Marine Engine GEX00001-UP


Parts turbocharger Caterpillar catalog:

Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.