2540786 TURBOCHARGER GP Caterpillar parts
3512B, G3516C, G3520C, G3520E, PMG3516
Rating:
Alternative (cross code) number:
CA2540786
254-0786
2540786
CA2540786
254-0786
2540786
Weight: 240 pounds 108 kg.
GENERATOR SET, POWER MODULE,
Related part:
2540786
TURBO GP-BASIC
20R3370
R
This part in 8 request:
Show.
This information for suppliers only!
2022-10-13
2022-03-28
2022-03-23
2021-08-04
2018-06-20
2018-06-20
2018-04-28
2018-04-27
Compatible equipment models: 2540786:
Information:
that are related to voltage regulation with reactive droop are listed below.:01 - Generator Output Voltage:02 - Ratio of Output Voltage to Sensing Voltage:03 - Generator Type:04 - Rated Generator Output Current:05 - Current Transformer (CT) Voltage at Rated Generator Current:06 - Knee Frequency:15 - Voltage Gain:16 - Integral Gain:17 - Proportional Gain:22 - Droop/CCC Select (only on part number 155-xxxx and later):30 - Droop PercentageThere are two primary objectives for parallel generator operation.
The generators are to share the real power requirements of the electrical load.
The generators are to share the reactive power requirements of the electrical load.The engine governors will control sharing of the real power requirements (kW) and the voltage regulator will control sharing of the reactive power requirements (KVAR) of the total system load.If the output voltage of one generator is slightly higher than the other generators, the generator will supply a lagging reactive current to the other generators that are connected to the group. The lagging reactive current will circulate between generators. The lagging reactive current can cause ampere overloading. One method that can be used in order to minimizing this effect is to cause the output voltage of an individual generator to sag, or "droop", in proportion to the lagging reactive current. The lagging reactive current value must be measured via a current transformer (CT). For proper reactive load sharing, the regulator must know the rated generator output current (parameter :04), the CT voltage at rated generator current (parameter :05) and the desired percentage of output voltage droop (parameter :30) when the generator is at rated reactive output current.As reactive lagging generator output current increases, the regulator will cause the output voltage to droop (lower the voltage) proportionally. If the measured reactive output current is leading, the output voltage will rise. In either case, this action will tend to reduce the reactive current for better KVAR sharing with other units. The droop percentage (parameter :30) controls the amount that the generator output voltage will vary for a given amount of reactive current. The polarity must be correct for the CT that is connected for the voltage to droop with the lagging current flow. The line loss compensation voltage gain (parameter :15) function can adversely affect load sharing. For reactive droop to work properly, parameter :15 should be set to zero.
The generators are to share the real power requirements of the electrical load.
The generators are to share the reactive power requirements of the electrical load.The engine governors will control sharing of the real power requirements (kW) and the voltage regulator will control sharing of the reactive power requirements (KVAR) of the total system load.If the output voltage of one generator is slightly higher than the other generators, the generator will supply a lagging reactive current to the other generators that are connected to the group. The lagging reactive current will circulate between generators. The lagging reactive current can cause ampere overloading. One method that can be used in order to minimizing this effect is to cause the output voltage of an individual generator to sag, or "droop", in proportion to the lagging reactive current. The lagging reactive current value must be measured via a current transformer (CT). For proper reactive load sharing, the regulator must know the rated generator output current (parameter :04), the CT voltage at rated generator current (parameter :05) and the desired percentage of output voltage droop (parameter :30) when the generator is at rated reactive output current.As reactive lagging generator output current increases, the regulator will cause the output voltage to droop (lower the voltage) proportionally. If the measured reactive output current is leading, the output voltage will rise. In either case, this action will tend to reduce the reactive current for better KVAR sharing with other units. The droop percentage (parameter :30) controls the amount that the generator output voltage will vary for a given amount of reactive current. The polarity must be correct for the CT that is connected for the voltage to droop with the lagging current flow. The line loss compensation voltage gain (parameter :15) function can adversely affect load sharing. For reactive droop to work properly, parameter :15 should be set to zero.
Caterpillar SIS machinery equipment:
Caterpillar SIS
G3516C Generator Set NWD00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set NWF00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set F6M00001-UP »
254-0786
TURBOCHARGER GP
PMG3516 Power Module GJK00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set GG300001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set HPY00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set HCY00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set GZZ00001-UP »
254-0786
TURBOCHARGER GP
G3520C Generator Set GZK00001-UP »
254-0786
TURBOCHARGER GP
G3520E Generator Set GZH00001-UP »
254-0786
TURBOCHARGER GP
G3520E Generator Set HAL00001-UP »
254-0786
TURBOCHARGER GP
G3520C Generator Set MAD00001-UP »
254-0786
TURBOCHARGER GP
3512C Marine Engine MKH00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set GZC00001-UP »
254-0786
TURBOCHARGER GP
PMG3516 Power Module JKK00001-UP POWERED BY G3516C Engine »
254-0786
TURBOCHARGER GP
G3516C Generator Set F6D00001-UP »
254-0786
TURBOCHARGER GP
G3516C Generator Set F6F00001-UP »
254-0786
TURBOCHARGER GP
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
2540784
TURBOCHARGER GP
G3520C
G3520C
2937896
TURBOCHARGER GP
G3516C, G3516E, G3520C, G3520E
G3516C, G3516E, G3520C, G3520E
2540789
TURBOCHARGER GP
G3516C, G3520C
G3516C, G3520C
2064152
TURBOCHARGER GP
G3520C
G3520C
2234852
TURBOCHARGER GP
G3520C
G3520C
2410998
TURBOCHARGER GP
G3516C, G3520C
G3516C, G3520C
2669674
TURBOCHARGER GP
G3516C, G3520C
G3516C, G3520C
2492861
TURBOCHARGER GP
G3516C
G3516C
2793484
TURBOCHARGER GP
G3516C, G3516E, G3520C, G3520E
G3516C, G3516E, G3520C, G3520E
2924061
TURBOCHARGER GP
G3516C
G3516C
2525825
TURBOCHARGER GP
G3520E
G3520E
2387766
TURBOCHARGER GP
3512B
3512B
6N8455
TURBOCHARGER GP
D398, D398A, D398B
D398, D398A, D398B
3983574
TURBOCHARGER GP
C1.5, CB22B, CB24B, CB32B, CC24B
C1.5, CB22B, CB24B, CB32B, CC24B
2265591
TURBOCHARGER GP
814F, 815F, 816F
814F, 815F, 816F
1933277
TURBOCHARGER GP
3508B
3508B
1348448
TURBOCHARGER GP
3406E
3406E
6N7519
TURBOCHARGER GP
621R, 980B
621R, 980B