AVSPARE.COM
parts catalog

TURBOCHARGER GP 2572205 - Caterpillar


2572205 TURBOCHARGER GP Caterpillar parts G3516
Rating:
18
Alternative (cross code) number:
CA2572205
257-2205
2572205
Caterpillar 2572205 TURBOCHARGER GP
Weight: 101 pounds 45 kg.

Buy TURBOCHARGER GP 2572205 Caterpillar genuine, new aftermarket tractor parts with delivery
GAS ENGINE, GENERATOR SET,

Related part:
2572205  TURBO GP-BASIC  10R2843  R

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$3,179.99

05 Apr 2025
44.08[19.84] pounds
CN: diamond-auto
SR4 G3516 turbocharger UTW92 751657-5002S 751657-5001S 257-2205 2572205
Generic Item Status: Brand New || Brand:Diamond || Manufacturer Part Number:751657-5002S 751657-0002 751657-0001 751657-5001S 751657-1 751657
$2,976.68

10 Jan 2025
44.08[19.84] Pounds
CN: diamond-auto
SR4 G3516 turbocharger UTW92 751657-5002S 751657-5001S 257-2205 2572205
Generic Item Status: Brand New || Brand:Diamond || Manufacturer Part Number:751657-5002S 751657-0002 751657-0001 751657-5001S 751657-1 751657
Number on catalog scheme: 1
  For full view, you need register

Compatible equipment models: 2572205:

GAS ENGINE  G3516  
GENERATOR SET  Caterpillar

Information:


Illustration 4 g00611596
10 Lead Wye Configuration - Low Voltage (for 3306B and 3406C generator sets only)
Terminal T0 is the neutral lead.
12 Lead
Illustration 5 g00661863
12 Lead Wye Configuration - High Voltage
Terminals T10, T11, and T12 become neutral connection when the terminals are tied together.
Illustration 6 g00611608
12 Lead Wye Configuration - Low Voltage
Terminals T10, T11, and T12 become neutral connection when the terminals are tied together.
Delta Configuration Diagrams
6 Lead
Illustration 7 g00669319
6 Lead Delta Configuration
12 Lead
Illustration 8 g00669312
12 Lead Delta Configuration
Terminals T6 and T9 become the neutral connection when the terminals are tied together and grounded. This configuration reflects the terminal T2 and T10 connection as the high phase.
SR500 Configurations
Illustration 9 g06267380
SR500 12 Lead Wye Configuration High Voltage
Illustration 10 g06267469
SR500 12 Lead Wye Configuration Low Voltage
Illustration 11 g06267491
SR500 12 Lead Delta Configuration
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground or to the hull of a vessel. This connection is the first one that is made at the installation. This connection is the last one that should be removed. If the generator set is on flexible or resilient pads, the ground connection must be flexible to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Silver soldered and bolted joints are electrically and mechanically sound.Neutral Connections
The generators with Wye Configuration usually have the neutral ground when the generator is installed. However, there are some cases when definite measures which can be taken to prevent grounds on the load side. The purpose of the grounding of the neutral is to prevent load side equipment damage.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. The excessive current will also collapse the generator voltage. The result depends on the particular generator electrical characteristics, type of fault and trip rating of the circuit breaker. An undervoltage device may be required to provide an adequate short circuit protection.There are some instances in which grounding the neutral wire is not desirable. An ungrounded generator neutral lead is acceptable in the applications in which definite measures have been taken to prevent grounds to the phase leads. An example of such measures is ground fault protective circuits. Ground fault protection requires that the entire group of distribution circuits should be studied and treated as a system. The owner should engage a certified and registered consultant if a new distribution system is being developed. The owner should also engage a certified and registered consultant if an existing system should be modified for the ground fault protection.Single Units
In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.In applications, in which definite measures are taken to prevent grounds to

Caterpillar parts catalog:

Caterpillar parts catalog
G3516 Engine Electronic Ignition System 4EK00001-UP
G3516 Generator Set CSZ00001-UP
G3516 Generator Set ZBA00001-UP
G3516 Engine WPW00001-UP
G3516 Gas Engine N6C00001-UP


Parts turbocharger Caterpillar catalog:

1020294 TURBOCHARGER GP
3512, 3512B, 3516, G3412, G3516
1W5285 TURBOCHARGER GP
3408, 3408B, 3408C, 3412, 3508, 3512, G3512, G3516
3157768 TURBOCHARGER GP
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2
2842712 TURBOCHARGER GP
C15, C15 I6, CX31-C15I, TH35-C15I
3S4440 TURBOCHARGER ASSEMBLY
D353C, D379, D398, G353D, G379, G398
1418965 TURBOCHARGER GP
G3408, G3408B, G3408C
1501213 TURBOCHARGER GP
CB-534C, CB-535B, CP-433C, CS-431C, CS-433C, PF-290B, PS-200B, PS-360B, TH103, TH62, TH63, TH82, TH83
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.