TURBOCHARGER 3167989 - Caterpillar



3167989 TURBOCHARGER Caterpillar parts C4.4
Rating:
83
Alternative (cross code) number:
CA3167989
316-7989
3167989
Caterpillar 3167989 TURBOCHARGER
Weight: 13 pounds 6 kg.

Buy TURBOCHARGER 3167989 Caterpillar genuine, new aftermarket tractor parts with delivery
INDUSTRIAL ENGINE,

Compare Prices:

As an associate, we earn commssions on qualifying purchases through the links below
$365.75

20 Nov 2025

CN: BCXFORK
BCXFORK GT2556S Turbocharger 316-7989 3167989 CA316-7989 fits Caterpillar C4.4 Engine
BCXFORK Please make sure your old turbocharger number and Part Number match the ones listed in the link before placing your order || Part Number: 316-7989 3167989 CA316-7989 || This item fits for Caterpillar C4.4 Engine || Manufacturer Warranty 1 Year || Turbo Model: GT2556S
$819.95

30 Oct 2025

US: KMP BRAND
316-7989 TURBOCHARGER Suitable For Caterpillar 3167989
KMP BRAND Suitable for Caterpillar
$339.00

30 Oct 2025

CN: Nancy-Parts sto
316-7989 3167989 Turbo GT2556S Turbocharger Fits for CAT Engine C4.4
XYohykai ◆Part Name◆:Turbo GT2556S Turbocharger || ◆Part Number◆:316-7989 3167989 || ◆Application◆:Fits for CAT Engine C4.4 || ◆Notice◆-Application information provided is for reference only. Please confirm the part number and compare old parts before purchase. If you have any question,pls feel free to ask us. || ◆Worth Choice◆-This product has stable performance high reliability easy installation and fast response.
Number on catalog scheme: 25
  For full view, you need register

Compatible equipment models: 3167989:

INDUSTRIAL ENGINE  C4.4   Caterpillar

Caterpillar parts catalog:

Caterpillar parts catalog
C4.4 Industrial Engine 44600001-UP
C4.4 Industrial Engine 44000001-UP
C4.4 Industrial Engine 2L200001-UP
C4.4 Industrial Engine 44600001-UP


Information:


FIG. 38. WIRING DIAGRAM
1. Power rectifier. A. Ammeter. V. Voltmeter.Dynamic Testing of Power Rectifiers
A-DC Ammeter 0-75 amps scaleV-DC Voltmeter 0-4 volt scaleTest rectifier installed in heat sink.
To check the forward current rating of a power rectifier, the rectifier must be installed in a heat sink with sufficient cooling to limit the case temperature.
Type S Rectifiers (35 Ampere Rating)
Adjust the DC supply voltage to obtain 35 amperes DC through meter (A). The DC voltage across meter (V) should be no more than 1.3 volts.Type T Rectifiers (50 Ampere Rating)
Adjust the DC supply voltage to obtain 50 amperes DC through meter (A). The DC voltage across meter (V) should be no more than 1.2 volts.
FIG. 39. TEST SET UP
1. Power rectifier. 2. Ammeter. 3. Voltmeter. 4. Separate DC source. 5. Hand rheostat.Installation of Power Rectifiers
See Fig. 40. Silicon stud-mounted diodes are manufactured with a variety of base and stud sizes. The use of the mounting stud accomplishes two functions; that is, electrical connection to the rectifier base and the transfer of thermal losses from the rectifier to the heat sink and cooling medium. The electrical connections are readily made with conventional screw type terminals. However, proper mounting to achieve low thermal resistance is not so readily accomplished. Consequently, take the following steps to obtain good terminal transfer of rectifier heat losses.The nut of a replacement power rectifier must be tightened to the torque specified to obtain maximum pressure of the two mating surfaces and, yet, not cause mechanical distortion of the rectifier base. Overtightening could stress the silicon crystal and cause changes in electrical characteristics or actual cracks in the crystal. A 9M6331 Pound-Inch Torque Wrench (2) (accurate in the listed torque range) should be used when tightening power rectifiers (1).1. Apply a thermally conductive lubricating film between the two mating surfaces to exclude the partially stagnant air which acts as a thermal insulating film.2. Tighten the nut on the power rectifier stud to the torque value shown in the chart.
FIG. 40. INSTALLING POWER RECTIFIERS
1. Power rectifiers. 2. Torque wrench.3. If a torque wrench is not available, tighten the rectifier stud nut finger tight against the lockwasher. Then tighten the nut an additional 60 degrees (one flat). Do not exceed this or the specified torque.Contact between the rectifier base and the heat sink (even when both are machined smooth) is actually a large number of point contacts. Between the points of contact is a thin film of dead air, which is a thermal barrier. To eliminate this thermal barrier, a thin film of thermally conductive lubricant should be applied to both mating surfaces before tightening. 4L7464 Silicone Grease (similar to Dow Corning #11 Compound) is recommended. A similar material, General Cement No. 8101 Silicone Grease, is available in one ounce tubes. This and other similar products can be purchased locally.Exciter Reactors
The following tests give a check of: 1. Exciter reactor polarity.2. Exciter reactor windings.To make the tests, AC (alternating current) and DC (direct current) voltmeters are needed. The 6V3030 Digital

Parts turbocharger Caterpillar catalog:

3160468 TURBOCHARGER
420E, C4.4, D3K XL, D4K XL, D5K LGP