6N8458 TURBOCHARGER GP Caterpillar parts
D353C, D398, D398B
Rating:
Alternative (cross code) number:
CA6N8458
6N-8458
6N8458
CA6N8458
6N-8458
6N8458
Weight: 74 pounds 34 kg.
GEN SET ENGINE, MARINE ENGINE,
Related part:
6N8458
TURBO GP-BASIC
0R5842
R
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 6N8458 Turbocharger Group for Models D353C/D398/D398B
CTP For models D353C/D398/D398B || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP For models D353C/D398/D398B || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP 6N8458 Turbocharger Group for Models D353C/D398/D398B
CTP For models D353C/D398/D398B || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP For models D353C/D398/D398B || Better performance and higher durability || Ready to ship || Country of origin: United States
6N8458
Images:
Compatible equipment models: 6N8458:
Information:
The 6V7925 Fuel Rate Indicator is an accurate fuel system diagnostic tool designed to measure engine fuel consumption. The indicator can be used in place of the 5P2150 Engine Horsepower Meter, and must be used with the 5P2148 Flowmeter (part of the 5P2149 Attachment Group).The 6V7925 Fuel Rate Indicator measures flow rates between 3 gallons per hour and 80 gallons per hour. Horsepower calculation and rpm measurement circuitry are not included in the fuel rate indicator. For rpm measurements, use the 6V3131 Multitach Group. Features
ADAPTABILITY: The indicator can measure fuel flow rates on all Caterpillar 1100, 3200, 3300 and 3400 series engines, and 6 1/4 bore "V" engines.HOUSING: A rugged, break-resistant plastic case protects the instrument from damage.GPH READOUT: Gallons per hour (gph) are directly displayed on a liquid crystal four digit display in numbers .5 inches high. The display is visible in direct sunlight and low light conditions.INPUT: Connection is provided for the 5P2157 Flowmeter Cable from the 5P2148 Flowmeter.POWER: Power for the indicator is supplied by an internal 9 Volt battery.AUTOMATIC SHUTOFF: A battery saver circuit automatically turns off the indicator when there is no input signal (less than approximately 3 gph).LOW BATTERY LIGHT: A red lamp glows on the front of the indicator when it is time to change the battery. If this lamp is on, the indicated flow may not be correct.PORTABILITY: The fuel rate indicator is a lightweight, hand-held instrument; an improvement over the more cumbersome 5P2150 Engine Horsepower Meter.CALIBRATION: A 6V3030 Multimeter (or equivalent) and a 1.5 Volt flashlight battery are used for easy bench calibration of the indicator.RELIABILITY: The 6V7925 Fuel Rate Indicator with the new 8T5118 Circuit Board has been designed and tested to withstand severe environmental factors such as high humidity, extreme temperatures, etc.Specifications
POWER: An internal 9 Volt battery (alkaline), type NEDA 1604A, is used to provide power for the fuel rate indicator.BATTERY LIFE: Approximately 20 hours of continuous operation.MEASUREMENT RANGE: 3.0 to 80 gallons per hour.ACCURACY: 6V7925 Indicator - .1 gph typical ( .2 gph max) in specified measurement and operating temperature range.6V7925 Indicator and 5P2148 Flowmeter - .5% of reading plus .1 gph (Example: At 20 gph, .5% = .1gph; plus .1 gph = .2 gph accuracy).READOUT UPDATE RATE: Approximately once per second.INPUT: Directly compatible with 5P2148 Flowmeter.CALIBRATION FACTOR: ... 1.250 Volts dc = 40.0 gph (31.25 mV = 1 gph).OPERATING TEMPERATURE RANGE: ... 32°F to 140°F(0°C to 60°C)STORAGE TEMPERATURE RANGE: ... +14°F to +140°F(-10°C to +90°C) with battery removed.SIZE: ... 7.5 in.(190 mm) x ... 4.4 in.(112 mm) x ... 1.6 in.(40 mm).WEIGHT: ... 1 lb(.45 kg)Components Of The 6V7925 Fuel Rate Indicator
The 6V7925 Fuel Rate Indicator includes the following service parts:1. 6V3063 Plastic Case (includes front and rear halves)2. 6V3114 Liquid Crystal Display3. 6V7756 Connector (dual Zebra strip, mounting frame and clear bezel for LCD) (not shown)4. 6V4179 A/D Converter (not shown)5. Front decal - SEES56036. Rear decal - SEES5645 (not shown), gallons/hour to liters/hour conversionsItems To Be Used For
ADAPTABILITY: The indicator can measure fuel flow rates on all Caterpillar 1100, 3200, 3300 and 3400 series engines, and 6 1/4 bore "V" engines.HOUSING: A rugged, break-resistant plastic case protects the instrument from damage.GPH READOUT: Gallons per hour (gph) are directly displayed on a liquid crystal four digit display in numbers .5 inches high. The display is visible in direct sunlight and low light conditions.INPUT: Connection is provided for the 5P2157 Flowmeter Cable from the 5P2148 Flowmeter.POWER: Power for the indicator is supplied by an internal 9 Volt battery.AUTOMATIC SHUTOFF: A battery saver circuit automatically turns off the indicator when there is no input signal (less than approximately 3 gph).LOW BATTERY LIGHT: A red lamp glows on the front of the indicator when it is time to change the battery. If this lamp is on, the indicated flow may not be correct.PORTABILITY: The fuel rate indicator is a lightweight, hand-held instrument; an improvement over the more cumbersome 5P2150 Engine Horsepower Meter.CALIBRATION: A 6V3030 Multimeter (or equivalent) and a 1.5 Volt flashlight battery are used for easy bench calibration of the indicator.RELIABILITY: The 6V7925 Fuel Rate Indicator with the new 8T5118 Circuit Board has been designed and tested to withstand severe environmental factors such as high humidity, extreme temperatures, etc.Specifications
POWER: An internal 9 Volt battery (alkaline), type NEDA 1604A, is used to provide power for the fuel rate indicator.BATTERY LIFE: Approximately 20 hours of continuous operation.MEASUREMENT RANGE: 3.0 to 80 gallons per hour.ACCURACY: 6V7925 Indicator - .1 gph typical ( .2 gph max) in specified measurement and operating temperature range.6V7925 Indicator and 5P2148 Flowmeter - .5% of reading plus .1 gph (Example: At 20 gph, .5% = .1gph; plus .1 gph = .2 gph accuracy).READOUT UPDATE RATE: Approximately once per second.INPUT: Directly compatible with 5P2148 Flowmeter.CALIBRATION FACTOR: ... 1.250 Volts dc = 40.0 gph (31.25 mV = 1 gph).OPERATING TEMPERATURE RANGE: ... 32°F to 140°F(0°C to 60°C)STORAGE TEMPERATURE RANGE: ... +14°F to +140°F(-10°C to +90°C) with battery removed.SIZE: ... 7.5 in.(190 mm) x ... 4.4 in.(112 mm) x ... 1.6 in.(40 mm).WEIGHT: ... 1 lb(.45 kg)Components Of The 6V7925 Fuel Rate Indicator
The 6V7925 Fuel Rate Indicator includes the following service parts:1. 6V3063 Plastic Case (includes front and rear halves)2. 6V3114 Liquid Crystal Display3. 6V7756 Connector (dual Zebra strip, mounting frame and clear bezel for LCD) (not shown)4. 6V4179 A/D Converter (not shown)5. Front decal - SEES56036. Rear decal - SEES5645 (not shown), gallons/hour to liters/hour conversionsItems To Be Used For
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
6N8464
TURBOCHARGER GP
D398, D398A, D398B
D398, D398A, D398B
7N2515
TURBOCHARGER GP
3306, 571G, 572G, D398, D398B, D7G
3306, 571G, 572G, D398, D398B, D7G
6L9509
TURBOCHARGER LUBRICATION VALVE GROUP
D398, D398A
D398, D398A
9N0111
TURBOCHARGER GROUP
3306, 572G, 621R, 815B, 966D, 972G, 973, 980B, D379, D379A, D379B, D398B, D7G
3306, 572G, 621R, 815B, 966D, 972G, 973, 980B, D379, D379A, D379B, D398B, D7G
6V3736
TURBOCHARGER MOUNTING
D379, D379B, D398, D398B, D399
D379, D379B, D398, D398B, D399
2802458
TURBOCHARGER GP
12M, 953D, D6K LGP, D6N
12M, 953D, D6K LGP, D6N
3826126
TURBOCHARGER GP
3516C
3516C
2077934
TURBOCHARGER GP
430D, 438D, 442D
430D, 438D, 442D
1189492
TURBOCHARGER GP
3508, 3512
3508, 3512
9Y7629
TURBOCHARGER GP
3126, 3406B, 3406C
3126, 3406B, 3406C
2W7899
TURBOCHARGER GP
3406, 3406B
3406, 3406B