Compatible equipment models: 6V0233:
Information:
Three-Phase Voltage Connections
The Wye Configuration and the Delta Configuration are given in the following diagrams.The terminals must be connected securely. Insulate the terminals with good quality electrical tape.If a Delta Configuration is being used, the generator winding pitch must be two-thirds. If the generator winding pitch is not two-thirds, there will be circulating current within the Delta. This circulating current will cause additional heat in the generator stator. In such cases, the generator must be derated.Wye Configuration Diagrams
6 Lead Generators
Illustration 1 g00626053
Typical Wye Configuration (60 Hz Six Lead)
12 Lead Generators
Illustration 2 g00637319
Typical Series Wye Configuration (60 Hz Twelve Lead)
Only for 3406E, 3412C, and 3500 series generator sets
Typical high-voltage connection.
Illustration 3 g00637320
Typical Parallel Wye Configuration (60 Hz Twelve Lead)
Only for 3406E, 3412C, and 3500 series generator sets
Typical low-voltage connection.
Delta Configuration Diagrams
6 Lead Generators
Illustration 4 g00626129
Typical Delta Configuration (60 Hz Six Lead)
12 Lead Generators
Illustration 5 g00626130
Typical Delta Configuration (60 Hz Twelve Lead)
Single-Phase Current From a Three-Phase Generator
Three-phase current and single-phase current can be taken simultaneously from a generator that is connected for three-phase service. In the Wye Configuration, connect the load to the three-phase leads (any two of the three leads). In the Delta Configuration, connect the load to the three-phase leads (any two of the three leads). In both configurations, the connection will provide single-phase voltage at the same voltage as three-phase voltage.Connect the load to any phase lead and neutral lead of the Wye Configuration. This connection will produce voltage at 58% of three-phase voltage.In a Delta Configuration (240 Volts, 60 Hz, and three-phase power), the following voltages will be present: 208 Volts between the high phase and neutral and 240 Volts between either of the low phases and neutral.Refer to Operation Section, "Generator Operation" for allowable single-phase loading unbalance.Single-phase power that is taken from a three-phase source can be a problem. Ensure that the single-phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.Wye Configuration Diagrams
6 Lead Generators
Illustration 6 g00626132
Single-Phase Voltage Diagram with Six-Lead Wye Configuration
12 Lead Generators
Illustration 7 g00637321
Single-Phase Voltage Diagram with Twelve-Lead Wye Configuration
Only for 3406E, 3412C, and 3500 series generator sets
Delta Configuration Diagrams
6 Lead Generators
Illustration 8 g00626135
Single-Phase Voltage Diagram with Six-Lead Delta Configuration
12 Lead Generators
Illustration 9 g00626136
Single-Phase Voltage Diagram with Twelve-Lead Delta Configuration
The Wye Configuration and the Delta Configuration are given in the following diagrams.The terminals must be connected securely. Insulate the terminals with good quality electrical tape.If a Delta Configuration is being used, the generator winding pitch must be two-thirds. If the generator winding pitch is not two-thirds, there will be circulating current within the Delta. This circulating current will cause additional heat in the generator stator. In such cases, the generator must be derated.Wye Configuration Diagrams
6 Lead Generators
Illustration 1 g00626053
Typical Wye Configuration (60 Hz Six Lead)
12 Lead Generators
Illustration 2 g00637319
Typical Series Wye Configuration (60 Hz Twelve Lead)
Only for 3406E, 3412C, and 3500 series generator sets
Typical high-voltage connection.
Illustration 3 g00637320
Typical Parallel Wye Configuration (60 Hz Twelve Lead)
Only for 3406E, 3412C, and 3500 series generator sets
Typical low-voltage connection.
Delta Configuration Diagrams
6 Lead Generators
Illustration 4 g00626129
Typical Delta Configuration (60 Hz Six Lead)
12 Lead Generators
Illustration 5 g00626130
Typical Delta Configuration (60 Hz Twelve Lead)
Single-Phase Current From a Three-Phase Generator
Three-phase current and single-phase current can be taken simultaneously from a generator that is connected for three-phase service. In the Wye Configuration, connect the load to the three-phase leads (any two of the three leads). In the Delta Configuration, connect the load to the three-phase leads (any two of the three leads). In both configurations, the connection will provide single-phase voltage at the same voltage as three-phase voltage.Connect the load to any phase lead and neutral lead of the Wye Configuration. This connection will produce voltage at 58% of three-phase voltage.In a Delta Configuration (240 Volts, 60 Hz, and three-phase power), the following voltages will be present: 208 Volts between the high phase and neutral and 240 Volts between either of the low phases and neutral.Refer to Operation Section, "Generator Operation" for allowable single-phase loading unbalance.Single-phase power that is taken from a three-phase source can be a problem. Ensure that the single-phase loading is equally distributed.Do not exceed the nameplate current rating for any one phase.Wye Configuration Diagrams
6 Lead Generators
Illustration 6 g00626132
Single-Phase Voltage Diagram with Six-Lead Wye Configuration
12 Lead Generators
Illustration 7 g00637321
Single-Phase Voltage Diagram with Twelve-Lead Wye Configuration
Only for 3406E, 3412C, and 3500 series generator sets
Delta Configuration Diagrams
6 Lead Generators
Illustration 8 g00626135
Single-Phase Voltage Diagram with Six-Lead Delta Configuration
12 Lead Generators
Illustration 9 g00626136
Single-Phase Voltage Diagram with Twelve-Lead Delta Configuration
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
1W5580
TURBOCHARGER GP
3408, 3408B, 3408E, 631D, 69D, 769C, 769D, 771D, 834B, 836, AD40, AD45, AE40, AE40 II, PM-565, PR-450, PR-450C
3408, 3408B, 3408E, 631D, 69D, 769C, 769D, 771D, 834B, 836, AD40, AD45, AE40, AE40 II, PM-565, PR-450, PR-450C
4W1148
TURBOCHARGER GP
3412, 3412C, 3516
3412, 3412C, 3516
7C6703
TURBOCHARGER GP
3412, 3412E
3412, 3412E
7N3205
TURBOCHARGER GP
3412, D399
3412, D399
7C2485
TURBOCHARGER GP
3412, 3412C
3412, 3412C
4W1237
TURBOCHARGER GP
3412, 3412C
3412, 3412C
6N7812
TURBOCHARGER GP
3412, 3412C
3412, 3412C
8C5059
TURBOCHARGER MOUNTING
3412, 3412C
3412, 3412C
6V4536
TURBOCHARGER MOUNTING
3412, D10N, D9L
3412, D10N, D9L
7E9820
TURBOCHARGER GP
RT100
RT100
3979979
TURBOCHARGER AS
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 906H2, 907H2, 908H2
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 906H2, 907H2, 908H2
3563518
TURBOCHARGER
430F, 450F, C4.4, CW-34, D5K2 XL
430F, 450F, C4.4, CW-34, D5K2 XL
4361920
TURBOCHARGER AS
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
3563519
TURBOCHARGER
416F, 420F, 428F, 432F, 434F, 444F, D3K2 LGP, D4K2 XL, D5K2 XL
416F, 420F, 428F, 432F, 434F, 444F, D3K2 LGP, D4K2 XL, D5K2 XL
3895352
TURBOCHARGER GP
272D, 299D, 910K, 914K
272D, 299D, 910K, 914K
1935112
TURBOCHARGER
3056
3056
6V9219
TURBOCHARGER MOUNTING
16H NA, 3406B
16H NA, 3406B
9X8575
TURBOCHARGER
3208
3208