7W2875 TURBOCHARGER GP Caterpillar parts
3208, PR-1000
Rating:
Alternative (cross code) number:
CA7W2875
7W-2875
7W2875
CA7W2875
7W-2875
7W2875
Weight: 38 pounds 17 kg.
COLD PLANER, TRUCK ENGINE,
Related part:
7W2875
TURBO GP-BASIC
0R5488
R
Cross Reference:
CATERPILLAR
0R5488,
4W1134,
7W2875,
GARRETT
466010-0006,
466010-6,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 7W2875 Turbocharger Group for Models 3208/PR-1000
CTP For models 3208/PR-1000 || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP For models 3208/PR-1000 || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP 7W2875 Turbocharger Group for Models 3208/PR-1000
CTP For models 3208/PR-1000 || Better performance and higher durability || Ready to ship || Country of origin: United States
CTP For models 3208/PR-1000 || Better performance and higher durability || Ready to ship || Country of origin: United States
Compatible equipment models: 7W2875:
Information:
Initial Start-Up
Preparing a generator for parallel operation requires special attention. Before attempting to parallel units for the first time, all units must be checked to be sure the following three conditions are met:1. Same phase rotation2. Same alternating current frequency.3. Same voltage adjustmentPhase Rotation
The phase rotation must be the same. A set of three light bulbs is used to determine whether the phase rotation of the incoming unit and the phase rotation of the line are the same.1. Connect the light bulbs between the generator leads and the corresponding line phase, i.e., terminal 1 to line 1 across the open circuit breaker.2. Start the units to be paralleled and bring them up to speed. As they approach the same speed the lights will start to blink. a. If the lights blink in sequence one of the units is connected backward. To correct this remove generator leads 1 and 3 at the circuit breaker and exchange them. This reverses the direction of phase rotation. Line 2 should always be connected to line 2.
Never attempt to work on electrically hot wiring. Stop the electric set before rewiring generator leads. Open circuit breakers before working on the equipment which they control.
b. If lights blink in unison the phase rotation of both engines is the same, and condition 1 has been met.Frequency Adjustment
The speed of units to be paralleled must be the same. Speed refers to the alternating current frequency.1. Allow each electric set to run under load long enough for the internal temperatures to stabilize (about one hour).2. Adjust the governor control to give rated frequency at full load.3. Remove the load and check the high idle speed; it should be approximately 3% above full load speed. If these speeds can not be obtained, contact your Caterpillar dealer.4. For the most consistent results, repeat steps 2 and 3 until condition 2 has been met.Voltage Adjustment
The voltage level and voltage droop adjustments determine the amount of circulating currents between generators. Carefully matched voltage regulator adjustments will reduce the circulating currents. Loads of .8 power factor (primarily motors) require a generator voltage droop of about 5%. Voltage droop is expressed as the percentage of voltage change from no load to full load. Use the same voltmeter to make adjustments on each unit to be paralleled.1. Adjust voltage as described for Single Unit Operation, Initial Start-Up.2. With the engine running at high idle, turn the voltage droop clockwise about 1/2 of full range.If driven load is to be unity power factor, set the voltage droop control on all generators at 1/2 of full range and proceed to Step 7. If driven load is to be normal (0.8 power factor) proceed to Step 3.3. Readjust the voltage level control until the voltage is about 5% above desired voltage.4. Apply full load at .8 power factor. If a generator is to be paralleled with other generators, the voltage droop of each generator must be the same to satisfactorily divide reactive load.5. Readjust the voltage droop control
Preparing a generator for parallel operation requires special attention. Before attempting to parallel units for the first time, all units must be checked to be sure the following three conditions are met:1. Same phase rotation2. Same alternating current frequency.3. Same voltage adjustmentPhase Rotation
The phase rotation must be the same. A set of three light bulbs is used to determine whether the phase rotation of the incoming unit and the phase rotation of the line are the same.1. Connect the light bulbs between the generator leads and the corresponding line phase, i.e., terminal 1 to line 1 across the open circuit breaker.2. Start the units to be paralleled and bring them up to speed. As they approach the same speed the lights will start to blink. a. If the lights blink in sequence one of the units is connected backward. To correct this remove generator leads 1 and 3 at the circuit breaker and exchange them. This reverses the direction of phase rotation. Line 2 should always be connected to line 2.
Never attempt to work on electrically hot wiring. Stop the electric set before rewiring generator leads. Open circuit breakers before working on the equipment which they control.
b. If lights blink in unison the phase rotation of both engines is the same, and condition 1 has been met.Frequency Adjustment
The speed of units to be paralleled must be the same. Speed refers to the alternating current frequency.1. Allow each electric set to run under load long enough for the internal temperatures to stabilize (about one hour).2. Adjust the governor control to give rated frequency at full load.3. Remove the load and check the high idle speed; it should be approximately 3% above full load speed. If these speeds can not be obtained, contact your Caterpillar dealer.4. For the most consistent results, repeat steps 2 and 3 until condition 2 has been met.Voltage Adjustment
The voltage level and voltage droop adjustments determine the amount of circulating currents between generators. Carefully matched voltage regulator adjustments will reduce the circulating currents. Loads of .8 power factor (primarily motors) require a generator voltage droop of about 5%. Voltage droop is expressed as the percentage of voltage change from no load to full load. Use the same voltmeter to make adjustments on each unit to be paralleled.1. Adjust voltage as described for Single Unit Operation, Initial Start-Up.2. With the engine running at high idle, turn the voltage droop clockwise about 1/2 of full range.If driven load is to be unity power factor, set the voltage droop control on all generators at 1/2 of full range and proceed to Step 7. If driven load is to be normal (0.8 power factor) proceed to Step 3.3. Readjust the voltage level control until the voltage is about 5% above desired voltage.4. Apply full load at .8 power factor. If a generator is to be paralleled with other generators, the voltage droop of each generator must be the same to satisfactorily divide reactive load.5. Readjust the voltage droop control
Caterpillar SIS machinery equipment:
Caterpillar SIS
PR-1000 PAVEMENT PROFILER 5XC00001-00137 (MACHINE) POWERED BY 3208,3412 ENGINE »
7W-2875
TURBOCHARGER GP
3208 INDUSTRIAL ENGINE 03Z00001-10092 »
7W-2875
TURBOCHARGER GP
3208 TRUCK ENGINE 02Z00001-40744 »
7W-2875
TURBOCHARGER GP
3208 Truck Engine Turbocharged 02Z40745-UP »
7W-2875
TURBOCHARGER GP
3208 Industrial Engine 03Z10093-UP »
7W-2875
TURBOCHARGER GP
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
1444568
TURBOCHARGER GP
3412, 3412C, 3412E, PM3412, PR-1000
3412, 3412C, 3412E, PM3412, PR-1000
4W7500
TURBOCHARGER GP
3412, PR-1000, PR-750B
3412, PR-1000, PR-750B
6V6414
TURBOCHARGER MOUNTING
3208, FB221
3208, FB221
2W7473
TURBOCHARGER GROUP
3208, 3608, 3616
3208, 3608, 3616
2122177
TURBOCHARGER GP
3126B, C7
3126B, C7
2183195
TURBOCHARGER GP
G3516C
G3516C
2404765
TURBOCHARGER GP
G3520C
G3520C
7C8429
TURBOCHARGER GP
3306, 3306B
3306, 3306B
2793343
TURBOCHARGER GP
C11, TH35-C11I
C11, TH35-C11I
2S9768
TURBOCHARGER ASSEMBLY
1693, D343
1693, D343
2393891
TURBOCHARGER GP
G3516C, G3520C
G3516C, G3520C
1325396
TURBOCHARGER GP
3306C
3306C
1942908
TURBOCHARGER GP
3126B, C7
3126B, C7