9Y8266 TURBOCHARGER GP Caterpillar parts
776C, 777B, 789, D11N
Rating:
Alternative (cross code) number:
CA9Y8266
9Y-8266
9Y8266
CA9Y8266
9Y-8266
9Y8266
Weight: 59 pounds 26 kg.
TRACK-TYPE TRACTOR, TRUCK,
Related part:
9Y8266
TURBO GP-BASIC
0R6006
R
You can buy:
US$1,050.00
14 Jul 2025
FridayParts
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 9Y8266 Turbocharger for Models 776C/777B/789/D11N
CTP For models 776C/777B/789/D11N || Better performance and higher durability || Ready to ship
CTP For models 776C/777B/789/D11N || Better performance and higher durability || Ready to ship
CAT 3516 Excavator E3516 S4DC TV83 JadeZan Turbocharger 9Y8266 465955-0001 4659550001
EWAIDI Part Number: 9Y8266 465955-0001 4659550001 || Applicable models: Fits for CAT 3516 Excavator E3516 S4DC TV83 || Warranty for a period of 1 year. || Enhances engine efficiency by optimizing air intake, helping to reduce fuel consumption while maintaining power output. || Each turbocharger is professionally tested for flow, pressure, and durability to guarantee reliable performance and customer satisfaction.
EWAIDI Part Number: 9Y8266 465955-0001 4659550001 || Applicable models: Fits for CAT 3516 Excavator E3516 S4DC TV83 || Warranty for a period of 1 year. || Enhances engine efficiency by optimizing air intake, helping to reduce fuel consumption while maintaining power output. || Each turbocharger is professionally tested for flow, pressure, and durability to guarantee reliable performance and customer satisfaction.
Compatible equipment models: 9Y8266:
Information:
An Automatic Start-Stop system is used when an engine must start with no one in attendance. The generator set must start, pick up the load, operate the load and stop after the load is removed.Starting The Engine
1. To start the engine when unattended, the engine room temperature must be at least 20°C (70°F) or the engine jacket water temperature must be 32°C (90°F). Jacket water heaters can maintain this temperature. 2. The Engine Control Switch (ECS) must be in the Automatic Start position. In this position, the engine will automatically start when a remote starting contact is closed. When used together with an Automatic Transfer Switch, the engine can be signalled to start and the load automatically transferred when commercial power fails. When commercial power is restored the Automatic Transfer Switch will automatically transfer the load back to the commercial power, provide a cool down time and shutdown the engine.In the Automatic Start position, the engine will automatically stop if the engine has a fault. The programmed Cool Down Timer will cause the engine to run unloaded at rated speed before shutting down.Standby Sets
If the generator set is used for a standby application with a remote transfer switch, place the Engine Control Switch in the Automatic position and adjust the engine speed speed and the generator voltage for proper operation of the generator with load after starting.Stopping The Engine
To stop the engine manually using the Automatic Start-Stop Control Panel, place the Engine Control Switch in the Stop position. If the Engine Control Switch is left in the Automatic position, the engine will stop automatically when the remote starting contacts open and the programmed cool down cycle is complete.Engine Shutdown Caused By Faults
The Automatic Start-Stop Module is equipped with engine protective devices. The shutdowns will protect the engine if a malfunction occurs that causes low oil pressure, high coolant temperature, engine overspeed, an overcrank condition, engine coolant loss (optional), or customer connected shutdowns. When a fault occurs and the engine shuts down, one of the fault indicators will light.Restarting The Engine
To restart the engine after a shutdown caused by a fault condition, perform the following:1. Turn the Engine Control Switch to Stop position.
Accidental starting of the engine can cause personal injury. To prevent accidental starting, disconnect the batteries before performing maintenance or repair work.
2. Correct the fault condition that caused the shutdown.3. Rotate the Engine Control Switch to the Off-Reset position.4. Make sure that the Emergency Stop buttons located on the control panel or the engine junction box are reset.5. Make sure that the Air Shutoff Lever located at the top of the air inlet housing is reset (if equipped).6. The system is ready to start if the Engine Control switch is turned to Manual or Automatic. For additional information, refer to the service manual SENR5832, Electronic Modular Control Panel II+ (EMCP II+) For MUI Engines.
1. To start the engine when unattended, the engine room temperature must be at least 20°C (70°F) or the engine jacket water temperature must be 32°C (90°F). Jacket water heaters can maintain this temperature. 2. The Engine Control Switch (ECS) must be in the Automatic Start position. In this position, the engine will automatically start when a remote starting contact is closed. When used together with an Automatic Transfer Switch, the engine can be signalled to start and the load automatically transferred when commercial power fails. When commercial power is restored the Automatic Transfer Switch will automatically transfer the load back to the commercial power, provide a cool down time and shutdown the engine.In the Automatic Start position, the engine will automatically stop if the engine has a fault. The programmed Cool Down Timer will cause the engine to run unloaded at rated speed before shutting down.Standby Sets
If the generator set is used for a standby application with a remote transfer switch, place the Engine Control Switch in the Automatic position and adjust the engine speed speed and the generator voltage for proper operation of the generator with load after starting.Stopping The Engine
To stop the engine manually using the Automatic Start-Stop Control Panel, place the Engine Control Switch in the Stop position. If the Engine Control Switch is left in the Automatic position, the engine will stop automatically when the remote starting contacts open and the programmed cool down cycle is complete.Engine Shutdown Caused By Faults
The Automatic Start-Stop Module is equipped with engine protective devices. The shutdowns will protect the engine if a malfunction occurs that causes low oil pressure, high coolant temperature, engine overspeed, an overcrank condition, engine coolant loss (optional), or customer connected shutdowns. When a fault occurs and the engine shuts down, one of the fault indicators will light.Restarting The Engine
To restart the engine after a shutdown caused by a fault condition, perform the following:1. Turn the Engine Control Switch to Stop position.
Accidental starting of the engine can cause personal injury. To prevent accidental starting, disconnect the batteries before performing maintenance or repair work.
2. Correct the fault condition that caused the shutdown.3. Rotate the Engine Control Switch to the Off-Reset position.4. Make sure that the Emergency Stop buttons located on the control panel or the engine junction box are reset.5. Make sure that the Air Shutoff Lever located at the top of the air inlet housing is reset (if equipped).6. The system is ready to start if the Engine Control switch is turned to Manual or Automatic. For additional information, refer to the service manual SENR5832, Electronic Modular Control Panel II+ (EMCP II+) For MUI Engines.
Caterpillar SIS machinery equipment:
Caterpillar SIS
776B TRACTOR & 777B TRUCK 4YC00001-UP (MACHINE) POWERED BY 3508 ENGINE »
9Y-8266
TURBOCHARGER GP
D11N TRACTOR / POWER SHIFT / 74Z00001-UP (MACHINE) POWERED BY 3508 ENGINE »
9Y-8266
TURBOCHARGER GP
789 TRUCK 9ZC00001-00610 (MACHINE) POWERED BY 3516 ENGINE »
9Y-8266
TURBOCHARGER GP
777C Truck 776C Tractor 2TK00001-UP (MACHINE) POWERED BY 3508 Engine »
9Y-8266
TURBOCHARGER GP
D11N Track-Type Tractor Power Shift 4HK00001-UP (MACHINE) POWERED BY 3508 Engine »
9Y-8266
TURBOCHARGER GP
Caterpillar parts catalog:
Parts turbocharger Caterpillar catalog:
1153306
TURBOCHARGER GP
5130, 5230, 776C, 789, 789B, D11N, D11R
5130, 5230, 776C, 789, 789B, D11N, D11R
3016871
TURBOCHARGER GP
776D, 777B, 777C, 777D, 789, 789B, 789C, 789D, 854G, 992G, 994F, 994H
776D, 777B, 777C, 777D, 789, 789B, 789C, 789D, 854G, 992G, 994F, 994H
3395907
TURBOCHARGER GP
789, 789B, 789C, 789D
789, 789B, 789C, 789D
2803549
TURBOCHARGER GP
D11N, D11R
D11N, D11R
3561157
TURBOCHARGER GP
C4.4, C4.4XQ100
C4.4, C4.4XQ100
1325300
TURBOCHARGER GP
3406E
3406E
1309725
TURBOCHARGER GP
3406E, C30, C32
3406E, C30, C32
7W9564
TURBOCHARGER GP
3512, 3516
3512, 3516
3619711
TURBOCHARGER GP
834H, 836H, 988H
834H, 836H, 988H