Measuring Fuel Dilution
Diesel fuel is chemically similar to the lubricants that are used in diesel engines. A slow fuel leak will blend the fuel into the oil. Normal operating temperatures may cause volatile parts of the fuel to vaporize. The fuel that remains in the oil is less volatile.A closed cup flash test can be performed to detect fuel dilution. The flash test is designed to measure the volatile parts of the fuel that are remaining in the oil. Detecting less volatile fuel is difficult. The lack of volatility reduces the accuracy of the flash test.Since the flash test does not accurately detect fuel dilution, do not use the flash test as the only measure of fuel dilution. Instead, verify the dilution by the following methods:
Gas chromatograph fuel dilution test
Oil viscosityThe test that uses a gas chromatograph is designed to measure fuel dilution in crankcase oils. The gas chromatograph can identify the small chemical differences between diesel fuel and lubricating oil. A gas chromatograph is used to measure fuel dilution at all Caterpillar regional SOS laboratories. Some Cat dealers also use a gas chromatograph. Even though the gas chromatograph provides a more accurate measure of fuel dilution, always verify the results with the viscosity test.A significant level of fuel dilution reduces oil viscosity. If an unacceptable level of fuel dilution is suspected, the kinematic viscosity of the oil must be measured.Fuel dilution that is greater than 4 percent will usually cause viscosity that is less than the specified viscosity grade. If the oil is still within the specified viscosity grade, fuel dilution is unlikely to have reached an unacceptable level. Use the following chart to determine if viscosity has reached the minimum acceptable level. The guidelines of viscosity in the chart are slightly less than the limits of the SAE viscosity grades. However, these guidelines still provide adequate engine protection.
Table 1
Viscosity Grade Minimum Oil Viscosity at 100 °C with Fuel Dilution Greater Than 4% as Measured by a Gas Chromatograph Action
0W-40
5W-40
10W-40
15W-40 12.0 cSt Investigate the cause of fuel dilution or reduce the engine oil change interval.
0W-30
5W-30
10W-30 9.0 cSt Verifying Fuel Dilution
Always verify fuel dilution by the combination of a viscosity test and a gas chromatograph test that gives a result of more than 4 percent. If a fuel dilution test cannot be performed locally, submit an oil sample to a Cat dealer for analysis.Probable Causes
Fuel injector seals
Fuel injector tip
Shaft seal for the high-pressure fuel pumpRecommended Actions
Note: The procedures have been listed in order of probability. Complete the procedures in order.
Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Contact with high-pressure fuel may cause personal injury or death. Wait 10 minutes after the engine has stopped to allow fuel pressure to purge before any service or repair is performed on the engine fuel lines.
Table 2
Troubleshooting Test Steps Values Results
1. Fuel Injector Seals
A.
Diesel fuel is chemically similar to the lubricants that are used in diesel engines. A slow fuel leak will blend the fuel into the oil. Normal operating temperatures may cause volatile parts of the fuel to vaporize. The fuel that remains in the oil is less volatile.A closed cup flash test can be performed to detect fuel dilution. The flash test is designed to measure the volatile parts of the fuel that are remaining in the oil. Detecting less volatile fuel is difficult. The lack of volatility reduces the accuracy of the flash test.Since the flash test does not accurately detect fuel dilution, do not use the flash test as the only measure of fuel dilution. Instead, verify the dilution by the following methods:
Gas chromatograph fuel dilution test
Oil viscosityThe test that uses a gas chromatograph is designed to measure fuel dilution in crankcase oils. The gas chromatograph can identify the small chemical differences between diesel fuel and lubricating oil. A gas chromatograph is used to measure fuel dilution at all Caterpillar regional SOS laboratories. Some Cat dealers also use a gas chromatograph. Even though the gas chromatograph provides a more accurate measure of fuel dilution, always verify the results with the viscosity test.A significant level of fuel dilution reduces oil viscosity. If an unacceptable level of fuel dilution is suspected, the kinematic viscosity of the oil must be measured.Fuel dilution that is greater than 4 percent will usually cause viscosity that is less than the specified viscosity grade. If the oil is still within the specified viscosity grade, fuel dilution is unlikely to have reached an unacceptable level. Use the following chart to determine if viscosity has reached the minimum acceptable level. The guidelines of viscosity in the chart are slightly less than the limits of the SAE viscosity grades. However, these guidelines still provide adequate engine protection.
Table 1
Viscosity Grade Minimum Oil Viscosity at 100 °C with Fuel Dilution Greater Than 4% as Measured by a Gas Chromatograph Action
0W-40
5W-40
10W-40
15W-40 12.0 cSt Investigate the cause of fuel dilution or reduce the engine oil change interval.
0W-30
5W-30
10W-30 9.0 cSt Verifying Fuel Dilution
Always verify fuel dilution by the combination of a viscosity test and a gas chromatograph test that gives a result of more than 4 percent. If a fuel dilution test cannot be performed locally, submit an oil sample to a Cat dealer for analysis.Probable Causes
Fuel injector seals
Fuel injector tip
Shaft seal for the high-pressure fuel pumpRecommended Actions
Note: The procedures have been listed in order of probability. Complete the procedures in order.
Contact with high pressure fuel may cause fluid penetration and burn hazards. High pressure fuel spray may cause a fire hazard. Failure to follow these inspection, maintenance and service instructions may cause personal injury or death.
Contact with high-pressure fuel may cause personal injury or death. Wait 10 minutes after the engine has stopped to allow fuel pressure to purge before any service or repair is performed on the engine fuel lines.
Table 2
Troubleshooting Test Steps Values Results
1. Fuel Injector Seals
A.
Caterpillar SIS machinery equipment:
Caterpillar SIS
D6M & D6M LGP Track-Type Tractor 2RN00001-UP (MACHINE) POWERED BY 3116 Engine »
203-3032
UNDERCARRIAGE GP
D6M TRACK-TYPE TRACTOR XL, LGP 3WN00001-UP (MACHINE) POWERED BY 3116 Engine »
203-3032
UNDERCARRIAGE GP
D6N XL, FTC, LGP TRACK-TYPE TRACTOR ALH00001-UP (MACHINE) POWERED BY 3126B Engine »
203-3032
UNDERCARRIAGE GP
D6N XL, D/S, LGP TRACK-TYPE TRACTOR AKM00001-UP (MACHINE) POWERED BY 3126B Engine »
203-3032
UNDERCARRIAGE GP
Caterpillar parts catalog:
Parts undercarriage Caterpillar catalog:
1196916
UNDERCARRIAGE AR
D6M, D6N
D6M, D6N
1989788
UNDERCARRIAGE GP
D6M, D6N
D6M, D6N
3998369
UNDERCARRIAGE AR
308E2 CR
308E2 CR
3489700
UNDERCARRIAGE AR
247B3, 257B3
247B3, 257B3
2488366
UNDERCARRIAGE AR
587R, 587T
587R, 587T
2748292
UNDERCARRIAGE AR
D6R II
D6R II