1N4556 V-BELT Caterpillar parts
916, 926, 973C, D6R II, D6R III, D7R XR, D9R, IT28
Rating:
Alternative (cross code) number:
CA1N4556
1N-4556
1N4556
CA1N4556
1N-4556
1N4556
Weight: 0.50 pounds 0 kg.
Information:
EFFECTIVE LENGTH
1689
mm
GROOVE WIDTH
12.7
mm
INTEGRATED TOOLCARRIER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
D&D PowerDrive 1N4556 Caterpillar Replacement Belt, 67.27" Length, Rubber
D&D PowerDrive Belt 17.53 x 67.27in OC || Material type- rubber || Manufactured by D&D PowerDrive || Made in China
D&D PowerDrive Belt 17.53 x 67.27in OC || Material type- rubber || Manufactured by D&D PowerDrive || Made in China
CTP 1N4556 External Engine V-Belt
CTP For External Engine || Highly Efficient || Easy in-and-out fit
CTP For External Engine || Highly Efficient || Easy in-and-out fit
Compatible equipment models: 1N4556:
Information:
Conditions Which Generate This Code:
Illustration 1 g01363194
Connections of the neutral start relayThis diagnostic code is associated with the neutral start relay. The FMI 6 means that the ECM has determined that there is a short to ground in the relay circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the relay is shorted to ground.
The relay has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 1675 FMI 6 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE RELAY.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the relay with the active diagnostic code from the machine harness. Expected Result:The FMI 6 changes to FMI 5 when the relay is disconnected.Results:
YES - The FMI 6 changes to FMI 5 when the relay is disconnected. The circuit is correct.Repair: The relay has failed. Replace the relay. Verify that the new relay corrects the problem.STOP
NO - The diagnostic code remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE RELAY FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The relay remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-68 to all other contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-68 and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors. Make sure that the harness connectors are fully seated and that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the vehicle.
Check the status of the diagnostic code.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active. The diagnostic code has not been corrected.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Prior to replacing an ECM, always contact your dealership for possible consultation with
Illustration 1 g01363194
Connections of the neutral start relayThis diagnostic code is associated with the neutral start relay. The FMI 6 means that the ECM has determined that there is a short to ground in the relay circuit. The possible causes of this diagnostic code are listed:
The energize circuit of the relay is shorted to ground.
The relay has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of SPN 1675 FMI 6 is active before performing this procedure.Note: Use a digital multimeter for the measurements in this procedure.Test Step 1. CHECK THE RELAY.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the relay with the active diagnostic code from the machine harness. Expected Result:The FMI 6 changes to FMI 5 when the relay is disconnected.Results:
YES - The FMI 6 changes to FMI 5 when the relay is disconnected. The circuit is correct.Repair: The relay has failed. Replace the relay. Verify that the new relay corrects the problem.STOP
NO - The diagnostic code remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE RELAY FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The relay remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact J2-68 to all other contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J2-68 and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors. Make sure that the harness connectors are fully seated and that the clips for each connector are completely fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the vehicle.
Check the status of the diagnostic code.Expected Result:The diagnostic code is active.Results:
YES - The diagnostic code is active. The diagnostic code has not been corrected.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. Prior to replacing an ECM, always contact your dealership for possible consultation with
Cat SIS web machinery list:
Parts v Caterpillar catalog:
4W8662
V-BELT SET
45, 926, IT28
45, 926, IT28
1303216
V-BELT SET
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G
6N6657
V-BELT
3408, 3412, D10R, D8L, D9R
3408, 3412, D10R, D8L, D9R
6L5115
V-BELT-RAW WATER PUMP
3208, D4E, D9R, M318, M320
3208, D4E, D9R, M318, M320
9L6645
V-BELT
3406B, 3406E, C18, C32, D10R, D9R
3406B, 3406E, C18, C32, D10R, D9R
2P7333
V-BELT
3208, 992, D10R, D7R II, D8K, D9R, PR-1000
3208, 992, D10R, D7R II, D8K, D9R, PR-1000
2160349
V-BELT
973C, D6R, D6R II, D6R III, D6R STD, D6T
973C, D6R, D6R II, D6R III, D6R STD, D6T
6N3113
V-BELT
910G, 916, 926, D4HTSK II, IT18B, IT28
910G, 916, 926, D4HTSK II, IT18B, IT28
2P5618
V-BELT SET
613B, 613C, 621, 916
613B, 613C, 621, 916
1S4699
V-BELT
375, 375 L, 5080, 824C, 825C, 826C, 916, 926, AD40, AD45, AE40, D8H
375, 375 L, 5080, 824C, 825C, 826C, 916, 926, AD40, AD45, AE40, D8H
7W8132
V-BELT
3508, D7R XR
3508, D7R XR
2160349
V-BELT
973C, D6R, D6R II, D6R III, D6R STD, D6T
973C, D6R, D6R II, D6R III, D6R STD, D6T
2364190
V-BELT
D6R II
D6R II
2067870
V-BELT
973C, D6R II, D6R III
973C, D6R II, D6R III
1N3463
V-BELT SET
936, 936F, 973C, G936
936, 936F, 973C, G936
7N9417
V-BELT SET
963, 973, 973C, D5H
963, 973, 973C, D5H
2289937
V-BELT
D6R, D7R
D6R, D7R
2W3906
V-BELT
D5H, D5HTSK II
D5H, D5HTSK II
1031612
V-BELT
517, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II
517, D4H, D4H XL, D4HTSK III, D5H, D5H XL, D5HTSK II
9Y9702
V-BELT
589
589
4W0752
V-BELT SET
589, D8L, D9N
589, D8L, D9N
1W0530
V-BELT SET-FAN
814B, 815B, 966D, 973
814B, 815B, 966D, 973