1W2934 V-BELT Caterpillar parts
416D, 420D, 420E, 424D, 428D, 430D, 430E, 432D, 432E, 434E, 442D, 442E, 444E, 554, 924G, 924GZ, 930G, D8L, D9L, IT28G
Rating:
Alternative (cross code) number:
CA1W2934
1W-2934
1W2934
CA1W2934
1W-2934
1W2934
Weight: 0.38 pounds 0 kg.
Information:
EFFECTIVE LENGTH
1206
mm
GROOVE WIDTH
12.7
mm
BACKHOE LOADER, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 1W2934 External Engine V-Belt
CTP For External Engine || Highly Efficient || Easy in-and-out fit
CTP For External Engine || Highly Efficient || Easy in-and-out fit
CTP 1W2934 External Engine V-Belt
CTP For External Engine || Highly Efficient || Easy in-and-out fit
CTP For External Engine || Highly Efficient || Easy in-and-out fit
Compatible equipment models: 1W2934:
Information:
Troubleshooting Guide
General
Do not open or close the exciter with the engine-generator operating. When the generator is operating, the heat sinks and exciter parts are electrically charged. Components will be damaged if a metal contact is made between the generator frame and the heat sinks or exciter parts.
A large percentage of reported electrical faults result from undetected mechanical deficiencies. Take time to examine the entire installation carefully and methodically. Separate mechanical from electrical deficiencies.A generator is essentially a constant speed device. RPM that is 5 to 10 percent above or below rated RPM can cause large variations in terminal voltage.Generator heating is the result of line current. The higher the line current, the greater the heat.A voltmeter and ammeter or kW meter will not necessarily indicate the KVA load on a generator because of the power factor of the load.Before attempting to repair the generator, be familiar with the operating principles of the generator.Recognize the apparent operational trouble and diagnose the trouble from the wiring diagram and troubleshooting guide.When troubleshooting for voltage, a generator can usually be operated at a low RPM. Voltage and cycles are directly proportional to RPM. A six pole, 60 cycle, 230 volt, 1200 RPM generator operating at a low idle of 900 RPM produces 173 volts at 45 cycles. For information on the electrical and mechanical characteristics of SRCR generators, make reference to the section INDUSTRIAL DIVISION DATA SHEETS: No. 70.0 and TECHNICAL INFORMATION FILE (TIF).Test Instruments
A Volt-Ohm-Milliameter having scales of approximately the following values:AC Volts ... 0-12, 1-100, 0-300DC Volts ... 0-50, 0-100, 0-150Ohms ... x 1, x 10, x 100, x 1000DC Amps ... 0-3A Kelvin or a Wheatstone Bridge is used to measure the resistance of either the generator revolving field or the stator winding.A 500 or 1000 Volt Megohmmeter is used to measure the generator stator revolving field insulation resistance.A DC Ammeter with appropriate ampere shunt.A tong-type Volt Ammeter with scales 0-600 volts and 0-600 amperes. Some generators are rated higher than 600 amperes, but these are normally connected with two or more conductors per phase. To measure line current for these generators, measure the current in each conductor per phase and add the individual conductor currents. See if generator is rated over 600 volts.A direct reading Tachometer or a 3 or 5 second intergrating tachometer which is a relatively precise indicator, providing the drive does not slip. When precise frequency control is required, a direct comparison with utility power can be made.
On generators rated above 600 volts, do not use direct reading test equipment to measure line voltage or line current (even through the instruments have high voltage scales). Potential and current transformers rated for applicable voltage must be used. DO NOT rely on test instrument insulation alone when working on power circuits above 600 volts.
Electrical instruments are not precisely accurate. Five percent difference in readings between two instruments is common. Multi-scale instruments can exhibit five percent difference between scales. Where uniform adjustments are necessary (as in parallel operation),
General
Do not open or close the exciter with the engine-generator operating. When the generator is operating, the heat sinks and exciter parts are electrically charged. Components will be damaged if a metal contact is made between the generator frame and the heat sinks or exciter parts.
A large percentage of reported electrical faults result from undetected mechanical deficiencies. Take time to examine the entire installation carefully and methodically. Separate mechanical from electrical deficiencies.A generator is essentially a constant speed device. RPM that is 5 to 10 percent above or below rated RPM can cause large variations in terminal voltage.Generator heating is the result of line current. The higher the line current, the greater the heat.A voltmeter and ammeter or kW meter will not necessarily indicate the KVA load on a generator because of the power factor of the load.Before attempting to repair the generator, be familiar with the operating principles of the generator.Recognize the apparent operational trouble and diagnose the trouble from the wiring diagram and troubleshooting guide.When troubleshooting for voltage, a generator can usually be operated at a low RPM. Voltage and cycles are directly proportional to RPM. A six pole, 60 cycle, 230 volt, 1200 RPM generator operating at a low idle of 900 RPM produces 173 volts at 45 cycles. For information on the electrical and mechanical characteristics of SRCR generators, make reference to the section INDUSTRIAL DIVISION DATA SHEETS: No. 70.0 and TECHNICAL INFORMATION FILE (TIF).Test Instruments
A Volt-Ohm-Milliameter having scales of approximately the following values:AC Volts ... 0-12, 1-100, 0-300DC Volts ... 0-50, 0-100, 0-150Ohms ... x 1, x 10, x 100, x 1000DC Amps ... 0-3A Kelvin or a Wheatstone Bridge is used to measure the resistance of either the generator revolving field or the stator winding.A 500 or 1000 Volt Megohmmeter is used to measure the generator stator revolving field insulation resistance.A DC Ammeter with appropriate ampere shunt.A tong-type Volt Ammeter with scales 0-600 volts and 0-600 amperes. Some generators are rated higher than 600 amperes, but these are normally connected with two or more conductors per phase. To measure line current for these generators, measure the current in each conductor per phase and add the individual conductor currents. See if generator is rated over 600 volts.A direct reading Tachometer or a 3 or 5 second intergrating tachometer which is a relatively precise indicator, providing the drive does not slip. When precise frequency control is required, a direct comparison with utility power can be made.
On generators rated above 600 volts, do not use direct reading test equipment to measure line voltage or line current (even through the instruments have high voltage scales). Potential and current transformers rated for applicable voltage must be used. DO NOT rely on test instrument insulation alone when working on power circuits above 600 volts.
Electrical instruments are not precisely accurate. Five percent difference in readings between two instruments is common. Multi-scale instruments can exhibit five percent difference between scales. Where uniform adjustments are necessary (as in parallel operation),
Caterpillar parts catalog:
Parts v Caterpillar catalog:
9L6654
V-BELT SET
3456, D9L
3456, D9L
7W3896
V-BELT SET
3208, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
3208, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D
4N8597
V-BELT SET
3054, 3208, 3406E, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, C-15, C-16, CS-551
3054, 3208, 3406E, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, C-15, C-16, CS-551
1N3743
V-BELT
3208, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 815B, 950B, 953B, 953C, 963, 980G II, 980H, 986H, CB-434D, CB-534D, CB-564D, CD-54, CS-54, D3G, D4G, D5G, E110B, E12...
3208, 416C, 416D, 420D, 424D, 426C, 428C, 428D, 430D, 432D, 436C, 438C, 438D, 442D, 815B, 950B, 953B, 953C, 963, 980G II, 980H, 986H, CB-434D, CB-534D, CB-564D, CD-54, CS-54, D3G, D4G, D5G, E110B, E12...
1P6868
V-BELT
229D, 554, 65E, 75E, 825C, 826C, 953, 980C, 980F, 992, D7G2, D8H, E180, R2900, R2900G
229D, 554, 65E, 75E, 825C, 826C, 953, 980C, 980F, 992, D7G2, D8H, E180, R2900, R2900G
2P6818
V-BELT
216, 236, 247, 267, 287, 420E, 430E, 432E, 434E, 442E, 444E, 824G, 825G, 826G, 920, 951B, 980G, D4D
216, 236, 247, 267, 287, 420E, 430E, 432E, 434E, 442E, 444E, 824G, 825G, 826G, 920, 951B, 980G, D4D
5L3308
V-BELT SET
214, 3054, 3054B, 3054C, 3054E, 3056, 416D, 420D, 424D, 428D, 430D, 432D, 442D, 924G, 924GZ, D330A, D333A, M312, M315
214, 3054, 3054B, 3054C, 3054E, 3056, 416D, 420D, 424D, 428D, 430D, 432D, 442D, 924G, 924GZ, D330A, D333A, M312, M315
1303216
V-BELT SET
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G
3K3408
V-BELT
3208, D9L, M312, M315
3208, D9L, M312, M315
0617140
V-BELT
3116, 312, 315, 317, 924G
3116, 312, 315, 317, 924G
7W6129
V-BELT
D10N, D8N, D9L
D10N, D8N, D9L
7W1665
V-BELT SET
D10N, D9L
D10N, D9L
2108338
V-BELT
TH210, TH215
TH210, TH215
2246639
V-BELT SET
TH210, TH215
TH210, TH215
5L3308
V-BELT SET
214, 3054, 3054B, 3054C, 3054E, 3056, 416D, 420D, 424D, 428D, 430D, 432D, 442D, 924G, 924GZ, D330A, D333A, M312, M315
214, 3054, 3054B, 3054C, 3054E, 3056, 416D, 420D, 424D, 428D, 430D, 432D, 442D, 924G, 924GZ, D330A, D333A, M312, M315
9L2248
V-BELT
1676, 1693, 3114, 3116, 3126, 318C, 319C, 320C, 320C FM, 322C, 5130, 950G, 962G, D343, D6D, IT62G, TH62, TH63, TH82, TH83
1676, 1693, 3114, 3116, 3126, 318C, 319C, 320C, 320C FM, 322C, 5130, 950G, 962G, D343, D6D, IT62G, TH62, TH63, TH82, TH83
2475895
V-BELT
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
256C, 262C, 272C, 277C, 287C, 297C, HM312, HM315
9M1091
V-BELT
1676, 3116, 312C, 312C L, 320 L, 320N, 613, 992, C9, TH210, TH215
1676, 3116, 312C, 312C L, 320 L, 320N, 613, 992, C9, TH210, TH215
3524169
V-BELT
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 906, 906H, 907H, 908, 908H
236B, 236B3, 242B3, 246C, 252B, 252B3, 256C, 257B3, 259B3, 262C, 262C2, 267B, 268B, 272C, 277C, 277C2, 279C, 279C2, 287C, 287C2, 289C, 289C2, 297C, 299C, 3044C, 906, 906H, 907H, 908, 908H
2354972
V-BELT
236B, 267B, 268B, 906, 906H, 907H
236B, 267B, 268B, 906, 906H, 907H
1P4334
V-BELT
14E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 3208, 414E, 416E, 422E, 428E, 928G, 938G, 950G, 962G, 966C, E200B, IT12B, IT28G, IT38G, IT62G
14E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 3208, 414E, 416E, 422E, 428E, 928G, 938G, 950G, 962G, 966C, E200B, IT12B, IT28G, IT38G, IT62G
1303216
V-BELT SET
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G
414E, 416E, 422E, 428E, 627G, 637G, 914G, 924G, 924GZ, 930G, 973C, D6R II, D6R III, IT14G, IT28G