7C9001 V-BELT Caterpillar parts
C18, C9.3, D8N, D8R
Rating:
Alternative (cross code) number:
CA7C9001
7C-9001
7C9001
CA7C9001
7C-9001
7C9001
Weight: 0.50 pounds 0 kg.
Information:
EFFECTIVE LENGTH
1664
mm
GROOVE WIDTH
15.88
mm
INDUSTRIAL ENGINE, TRACK-TYPE TRACTOR,
You can buy:
US$18.99
28 May 2025
FridayParts
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Aftermarket Belt 7C-9001 Fit Intended For Engine C9 C18 3406 Tractor D8N D8R
Generic
Generic
7C9001 Belt (New AFTERMARKET) - G&T Engine Parts
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 0.66 lbs || Dimensions: 10-7.15-28.15 in || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts Condition: NEW AFTERMARKET || Weight: 0.66 lbs || Dimensions: 10-7.15-28.15 in || Items are sold by part number only. Picture is for illustration purposes and the part or parts may be different in color or quantity. || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
This part in 10 request:
Show.
This information for suppliers only!
2025-04-01
2024-01-29
2023-11-07
2023-11-07
2023-02-13
2022-08-07
2022-03-14
2020-03-09
2018-09-09
2017-05-03
Compatible equipment models: 7C9001:
Information:
Exposed Conductive Parts (ECP) Cabinet Connections
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
The information in this section applies to UPS, external bypass, SSC, and battery cabinets.Interconnect the ECP units and tie down the wires.
Open the door by using a Ronis 405 key. The access panels must be removed.
Install an additional ground cable (not supplied) from one ECP unit to each of the other ECP cabinets that are in the installation. Refer to Illustration 1. The ground cable must meet the following criteria:
Minimum size of the ground cable is half the size of a cable used for one of the phases
The ground cable must be the same type of cable as used for phase conductors
The ground cable must be as short as possible
Illustration 1 g02463876
Synchronization Module Connections
Refer to Special Instruction, REHS5168 for installation instructions.Back Feed Option Connections
The back feed option on normal and bypass AC inputs is compulsory if the IEC 62040-1 rev 2008 code is to be complied with.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Illustration 2 g02465362
Illustration 3 g02465376
Back feed option connections (1) Access panel installed (2) Neutral bar (3) Ground bar (4) To UPS (5) To earth ground (6) To Normal or AC bypass lineNote: The diameter of the holes for the terminal connections for the back feed cabinet is 13 mm (0.52 inch).Connecting the Normal AC Line Back Feed Cabinet
Note: Refer to Illustration 3 for the following steps.
Remove the access panel (1) .
Connect the PE or the PEN conductor to the ground bar (3) .
Connect the normal AC conductors (6). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Connect the UPS conductors (4). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Install the access panel (1) .Connecting the Bypass AC Line Back Feed Cabinet
Note: Refer to Illustration 3 for the following steps.
Remove the access panel (1) .
Connect the PE or the PEN conductor to the ground bar (3) .
Connect the neutral conductor to the neutral bar (2) .
Connect the AC bypass conductors (6). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Connect the UPS conductors (4). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Install the access panel (1) .Installing the 400 mm Auxiliary Cabinet
The following steps provide information to assemble a 400 mm auxiliary cabinet to other UPS cabinets.
Remove the two inter-cabinet uprights (7) that are located on the rearward sided the 400 mm (16 inch) cabinet.
Illustration 4 g02475352
(6) Rear access panel (7) Inter-cabinet uprights (8) Side access panel
Install the rear panel (6) of the 400 mm (16 inch) cabinet with the
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
The information in this section applies to UPS, external bypass, SSC, and battery cabinets.Interconnect the ECP units and tie down the wires.
Open the door by using a Ronis 405 key. The access panels must be removed.
Install an additional ground cable (not supplied) from one ECP unit to each of the other ECP cabinets that are in the installation. Refer to Illustration 1. The ground cable must meet the following criteria:
Minimum size of the ground cable is half the size of a cable used for one of the phases
The ground cable must be the same type of cable as used for phase conductors
The ground cable must be as short as possible
Illustration 1 g02463876
Synchronization Module Connections
Refer to Special Instruction, REHS5168 for installation instructions.Back Feed Option Connections
The back feed option on normal and bypass AC inputs is compulsory if the IEC 62040-1 rev 2008 code is to be complied with.
Bodily contact with electrical potential can cause bodily injury or death.To avoid the possibility of injury or death, ensure that the main power supply has been disconnected before performing any maintenance or removing any modules.
Illustration 2 g02465362
Illustration 3 g02465376
Back feed option connections (1) Access panel installed (2) Neutral bar (3) Ground bar (4) To UPS (5) To earth ground (6) To Normal or AC bypass lineNote: The diameter of the holes for the terminal connections for the back feed cabinet is 13 mm (0.52 inch).Connecting the Normal AC Line Back Feed Cabinet
Note: Refer to Illustration 3 for the following steps.
Remove the access panel (1) .
Connect the PE or the PEN conductor to the ground bar (3) .
Connect the normal AC conductors (6). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Connect the UPS conductors (4). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Install the access panel (1) .Connecting the Bypass AC Line Back Feed Cabinet
Note: Refer to Illustration 3 for the following steps.
Remove the access panel (1) .
Connect the PE or the PEN conductor to the ground bar (3) .
Connect the neutral conductor to the neutral bar (2) .
Connect the AC bypass conductors (6). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Connect the UPS conductors (4). Install L1 on the left terminal, L2 on the center terminal, and L3 on the right terminal.
Install the access panel (1) .Installing the 400 mm Auxiliary Cabinet
The following steps provide information to assemble a 400 mm auxiliary cabinet to other UPS cabinets.
Remove the two inter-cabinet uprights (7) that are located on the rearward sided the 400 mm (16 inch) cabinet.
Illustration 4 g02475352
(6) Rear access panel (7) Inter-cabinet uprights (8) Side access panel
Install the rear panel (6) of the 400 mm (16 inch) cabinet with the
Caterpillar parts catalog:
Parts v Caterpillar catalog:
9L6724
V-BELT SET
325 FM L, 325 L, 3406, 3406B, 3406C, 3406E, 3408, 3412, 3412E, C-15, C-16, C13, C9.3, CX31-C13I, G3406, TH48-E70
325 FM L, 325 L, 3406, 3406B, 3406C, 3406E, 3408, 3412, 3412E, C-15, C-16, C13, C9.3, CX31-C13I, G3406, TH48-E70
5N2346
V-BELT SET
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C15, C18, C9.3, CX31-C15I, CX35-P800, TH35-C15I
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, C-15, C-16, C15, C18, C9.3, CX31-C15I, CX35-P800, TH35-C15I
9L6646
V-BELT SET
3116, 3126, 3406B, C13, C9.3, CX31-C13I
3116, 3126, 3406B, C13, C9.3, CX31-C13I
9L6647
V-BELT GP
3196, 3406, 3406B, 3406C, 3408E, 3412E, C-12, C12, C18, C27, C32, CX35-P800, G3406, TH48-E70
3196, 3406, 3406B, 3406C, 3408E, 3412E, C-12, C12, C18, C27, C32, CX35-P800, G3406, TH48-E70
2S9506
V-BELT
428, 621E, 621F, 623E, 623F, 627E, 627F, D10N, D250B, D8H, D8R, D8R II
428, 621E, 621F, 623E, 623F, 627E, 627F, D10N, D250B, D8H, D8R, D8R II
7E7645
V-BELT
C-12, C12, C9.3
C-12, C12, C9.3
9N1320
V-BELT
3126B, 3408, 3408C, 3412, 3412C, 3412E, 578, 583R, 587R, 621E, 621F, 621G, 623E, 623G, 627E, 627F, 627G, D8N
3126B, 3408, 3408C, 3412, 3412C, 3412E, 578, 583R, 587R, 621E, 621F, 621G, 623E, 623G, 627E, 627F, 627G, D8N
6N0073
V-BELT
245, 621, 621B, 627F, C13, C9.3, CX31-C13I
245, 621, 621B, 627F, C13, C9.3, CX31-C13I
4P8088
V-BELT
C9.3
C9.3
4N8221
V-BELT
589, C9.3, D8L, D9N
589, C9.3, D8L, D9N
9L4479
V-BELT
D8N, R2900G
D8N, R2900G
7W6129
V-BELT
D10N, D8N, D9L
D10N, D8N, D9L
9L6641
V-BELT
3408, 3408C, 3408E, 3412, 3412C, 3412E, 834B, 836, 988F II, C13, C15, C18, C32, CX31-C13I, CX31-C15I, CX35-P800, TH35-C15I
3408, 3408C, 3408E, 3412, 3412C, 3412E, 834B, 836, 988F II, C13, C15, C18, C32, CX31-C13I, CX31-C15I, CX35-P800, TH35-C15I
8N6711
V-BELT SET
3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, G3516B, G3520B
3508, 3508B, 3512, 3512B, 3516, 3516B, 3516C, G3516B, G3520B
1535625
V-BELT SET
3412, 3412C, C15
3412, 3412C, C15
2699117
V-BELT
C4.4
C4.4
4N2531
V-BELT
3412, C13, C27, C32, CX31-C13I, D10R, TH48-E70
3412, C13, C27, C32, CX31-C13I, D10R, TH48-E70
4P1666
V-BELT
C32
C32
6N6650
V-BELT
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, AD40, AD45, AE40, AE40 II, C15, C18, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3412, PM-565, PM-565B, TH35-C15I
3406B, 3406C, 3406E, 3408, 3408C, 3408E, 3412, 3412C, 3412E, 3456, AD40, AD45, AE40, AE40 II, C15, C18, CX31-C15I, CX31-C18I, CX35-C18I, CX35-P800, G3412, PM-565, PM-565B, TH35-C15I
9Y4051
V-BELT SET
3408
3408
9Y4047
V-BELT SET
3408
3408
4N2532
V-BELT SET
320B, 322C FM, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412E, G3406
320B, 322C FM, 3406, 3406B, 3406C, 3408, 3408C, 3408E, 3412, 3412C, 3412E, G3406
2S5218
V-BELT
3208, CB-634, D8H, R2900
3208, CB-634, D8H, R2900
2P6212
V-BELT
120, 3208, 941, 951B, 966C, D6C, D6D
120, 3208, 941, 951B, 966C, D6C, D6D