1246037 VALVE GP-MOD Caterpillar parts
Rating:
Alternative (cross code) number:
CA1246037
124-6037
1246037
CA1246037
124-6037
1246037
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$310.52
03 Sep 2022
1.0[0.45] Pounds
US: Autumn Supply
Capital Safety - DBI/SALA 1246037 EZ-Stop Manual Synthetic Rope Adjuster With 3' Shock Absorbing Lanyard, English, 15.34 fl. oz., Plastic, 1" x 1" x 1"
Capital Safety - DBI/SALA Manual design allows user to fix in place || Ideal for work positioning or restraint
Capital Safety - DBI/SALA Manual design allows user to fix in place || Ideal for work positioning or restraint
Information:
Starting Above 0°C (32°F)
Key must be in run position with engine running to maintain electrical and hydraulic functions and prevent serious machine damage.If the engine does not start, return the key to OFF before returning it to START.Do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.
1. Make sure the battery disconnect switch is in the ON position. 2. Make sure the circuit breaker reset button remains depressed. 3. This machine is equipped with an engine neutral start system. The system allows engine starting only when the hydraulic activation control lever is in the LOCKED position. Move the hydraulic activation control lever to the LOCKED position.4. Move the implement control levers to the HOLD position. 5. Turn engine start switch (1) to the ON position. 6. All of indicators on the monitor panel should be activated for approximately 2.5 seconds and the action alarm should sound for one second. If any of the indicators are not activated or the action alarm does not sound, have the electrical system checked and all necessary repairs made before starting the engine.7. Turn engine speed dial (2) to position "1".8. Turn engine start switch (1) to the START position.9. Release the engine start switch key after the engine starts.Starting Below 0°C (32°F) (If Equipped with Ether Starting Aid)
Inject starting aid (ether), only while cranking the engine.Use sparingly, excessive ether without cranking can cause piston and ring damage.Wait approximately two seconds before injecting again.Use ether for cold starting purposes only.After every 30 seconds of engine cranking, allow two minutes for starting motor to cool before cranking again.
1. Repeat steps 1 through 8 in Starting Above 0°C (32°F). 2. Push the front of starting aid (ether) switch and release.3. Operate the starting aid switch every two seconds while cranking the engine. Continue use until the engine starts and is running smoothly.4. Release the engine start switch key when engine starts. Ether start cylinder or bottle container is located in the radiator compartment. See Ether Starting Aid Cylinder in the When Required section for container information.For starting below -18°C (0°F), use of optional cold weather starting aids is recommended. A coolant heater, fuel heater, jacket water heater or extra battery capacity may be required.At temperature below -23°C (-10°F), consult your Caterpillar dealer, or refer to the Operation & Maintenance Manual for Cold Weather Operation Recommendations SEBU5898, available from your Caterpillar dealer.Starting with Jumper Cables
Batteries give off flammable fumes that can explode.Prevent sparks near the batteries. They could cause vapors to explode. Do not allow jump cable ends to contact each other or the machine.Do not smoke when checking battery electrolyte levels.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.Always wear eye protection when starting a machine with jump cables.Improper jump procedures can cause an explosion resulting in personal injury.Always connect the battery positive (+) to battery positive (+) and the battery negative (-) to battery negative (-).Jump only
Key must be in run position with engine running to maintain electrical and hydraulic functions and prevent serious machine damage.If the engine does not start, return the key to OFF before returning it to START.Do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.
1. Make sure the battery disconnect switch is in the ON position. 2. Make sure the circuit breaker reset button remains depressed. 3. This machine is equipped with an engine neutral start system. The system allows engine starting only when the hydraulic activation control lever is in the LOCKED position. Move the hydraulic activation control lever to the LOCKED position.4. Move the implement control levers to the HOLD position. 5. Turn engine start switch (1) to the ON position. 6. All of indicators on the monitor panel should be activated for approximately 2.5 seconds and the action alarm should sound for one second. If any of the indicators are not activated or the action alarm does not sound, have the electrical system checked and all necessary repairs made before starting the engine.7. Turn engine speed dial (2) to position "1".8. Turn engine start switch (1) to the START position.9. Release the engine start switch key after the engine starts.Starting Below 0°C (32°F) (If Equipped with Ether Starting Aid)
Inject starting aid (ether), only while cranking the engine.Use sparingly, excessive ether without cranking can cause piston and ring damage.Wait approximately two seconds before injecting again.Use ether for cold starting purposes only.After every 30 seconds of engine cranking, allow two minutes for starting motor to cool before cranking again.
1. Repeat steps 1 through 8 in Starting Above 0°C (32°F). 2. Push the front of starting aid (ether) switch and release.3. Operate the starting aid switch every two seconds while cranking the engine. Continue use until the engine starts and is running smoothly.4. Release the engine start switch key when engine starts. Ether start cylinder or bottle container is located in the radiator compartment. See Ether Starting Aid Cylinder in the When Required section for container information.For starting below -18°C (0°F), use of optional cold weather starting aids is recommended. A coolant heater, fuel heater, jacket water heater or extra battery capacity may be required.At temperature below -23°C (-10°F), consult your Caterpillar dealer, or refer to the Operation & Maintenance Manual for Cold Weather Operation Recommendations SEBU5898, available from your Caterpillar dealer.Starting with Jumper Cables
Batteries give off flammable fumes that can explode.Prevent sparks near the batteries. They could cause vapors to explode. Do not allow jump cable ends to contact each other or the machine.Do not smoke when checking battery electrolyte levels.Electrolyte is an acid and can cause personal injury if it contacts skin or eyes.Always wear eye protection when starting a machine with jump cables.Improper jump procedures can cause an explosion resulting in personal injury.Always connect the battery positive (+) to battery positive (+) and the battery negative (-) to battery negative (-).Jump only
Parts valve Caterpillar catalog:
1245846
VALVE GP-MTG&
Caterpillar
Caterpillar
1245662
VALVE AR-BLCD
Caterpillar
Caterpillar
1245121
VALVE-SWITCH
Caterpillar
Caterpillar
1244962
VALVE GP-MTG&
Caterpillar
Caterpillar
1243499
VALVE GP-
Caterpillar
Caterpillar
1242905
VALVE GP-
Caterpillar
Caterpillar
1250407
VALVE GP
Caterpillar
Caterpillar
1248039
VALVE
Caterpillar
Caterpillar
1247866
VALVE KIT
Caterpillar
Caterpillar
1247819
VALVE AS
Caterpillar
Caterpillar
1247524
VALVE KIT
Caterpillar
Caterpillar
1246148
VALVE GP-
Caterpillar
Caterpillar