AVSPARE.COM
parts catalog

VALVE GP-BANK 2 1294599 - Caterpillar


1294599 VALVE GP-BANK 2 Caterpillar parts D6E, D6G SR
Rating:
64
Alternative (cross code) number:
CA1294599
129-4599
1294599
Caterpillar 1294599 VALVE GP-BANK 2
Weight: 70 pounds 31 kg.

Buy VALVE GP-BANK 2 1294599 Caterpillar genuine, new aftermarket tractor parts with delivery
TRACK-TYPE TRACTOR,

Compatible equipment models: 1294599:

TRACK-TYPE TRACTOR  D6E   D6G SR   Caterpillar
Number on catalog scheme:
  For full view, you need register

Information:


Illustration 1 g02476663
Connections of the Machine Feature Alarm
This diagnostic code is associated with the Machine Feature Alarm. The alarm is powered by an "ON/OFF" driver circuit. The FMI 03 diagnostic code is activated when the ECM detects an above normal voltage of the alarm circuit. The following conditions could cause this diagnostic code to be activated:
The energize circuit of the alarm is shorted to another voltage source.
The ECM has failed. This condition is unlikely.Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, that all connections are secure and that all connections are in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE ALARM FOR A SHORT
Turn the disconnect switch and the key start switch to the OFF position.
Disconnect the machine harness connector from the alarm. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness connectors for the ECM, measure the resistance from contact J2-5 (wire X416-OR(Orange)) to all of the other contacts that are used in the J1 and J2 connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.
NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. Repair: The short is between wire X416-OR(Orange) and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the alarm and the ECM remain disconnected.
At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the alarm wire X416-OR(Orange) and the socket at contact J2-5 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active CID 2914 FMI 03 diagnostic code. Expected Result:The CID 2914 FMI 03 diagnostic code is no longer active. A CID 2914 FMI 05 diagnostic code is now active.Results:
YES - The CID 2914 FMI 03 diagnostic code is no longer active. A CID 2914 FMI 05 diagnostic code has become active after the alarm circuit is disconnected. The ECM has

Caterpillar parts catalog:

Caterpillar parts catalog
D6G Track-Type Tractor Super Rural 3SR00001-UP (MACHINE) POWERED BY 3306 Engine
D6G Track-Type Tractor Power Shift 2MJ02654-UP (MACHINE) POWERED BY 3306 Engine


Parts valve Caterpillar catalog:

3137668 VALVE GP-SOLENOID
621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725, 725C, 730, 730C, 793F CMD, 834K, 836K, 938H, 950H, 950K, 962H, 962K, 963D, 966H, 966K, 966M, 966M XE, 972H, 972K, 972M, 972M XE, 973D, 980K...
1671555 VALVE GP-PRESSURE CONTROL
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 521, 521B, 522, 522B, 532, 541, 541 2, 545, 551, 552, 552 2, TK711, TK721, TK722, TK732, TK741, TK751, TK752
7K2738 VALVE AS-PARK & SECONDARY
518, 528, 621, 621B, 621E, 621F, 623B, 623E, 623F, 627B, 627E, 627F, 631D, 631E, 633D, 633E II, 637D, 637E, 639D, 641B, 651E, 657B, 657E, 814, 815, 816, 920, 930, 930R, 950, 966C, 966R, 980, 980B, D9G...
2537766 VALVE GP-PUMP CONTROL
M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH
3506977 VALVE GP-BACK PRESSURE
2384C, 2484C, 320E, 320E L, 320E LN, 320E LRR, 320E RR, 323E L, 559C, 579C, 924K, 930K, 938K
1117457 VALVE GP-SOLENOID
350, 375, 5130, 5130B, 5230
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.