1U2648 VALVE GP Caterpillar parts
772B, 773B
Rating:
Alternative (cross code) number:
CA1U2648
1U-2648
1U2648
CA1U2648
1U-2648
1U2648
Weight: 20 pounds 9 kg.
TRACTOR, TRUCK,
Information:
Removal Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the refrigerant. Refer to Service Manual, SENR5664, "All Products Air Conditioning and Heating Systems with R134a for All Caterpillar Machines" for the recovery and charging procedures. Refer to Special Publication, NENG2500, "Air Conditioning Tools" for the correct tools.
Illustration 1 g03776063
If equipped with an HVAC pre-cleaner, remove tube assembly (1) and remove cover (4) in order to disconnect harness (3).
Remove cover (2).
Illustration 2 g03777618
Disconnect harness assembly (5) and cable assembly (6). Remove bolts (7). Disconnect tube assemblies (10) and remove the seals. Remove bolt (11) disconnecting ground cables.
Remove bolts (9) and refrigerant compressor (8). Installation Procedure
Install refrigerant compressor (8) in the reverse order of removal.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Recover the refrigerant. Refer to Service Manual, SENR5664, "All Products Air Conditioning and Heating Systems with R134a for All Caterpillar Machines" for the recovery and charging procedures. Refer to Special Publication, NENG2500, "Air Conditioning Tools" for the correct tools.
Illustration 1 g03776063
If equipped with an HVAC pre-cleaner, remove tube assembly (1) and remove cover (4) in order to disconnect harness (3).
Remove cover (2).
Illustration 2 g03777618
Disconnect harness assembly (5) and cable assembly (6). Remove bolts (7). Disconnect tube assemblies (10) and remove the seals. Remove bolt (11) disconnecting ground cables.
Remove bolts (9) and refrigerant compressor (8). Installation Procedure
Install refrigerant compressor (8) in the reverse order of removal.
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
1U2633
VALVE
773B, 776
773B, 776
1U2645
VALVE GP
776, 777
776, 777
6T0734
VALVE AS
777
777
5T1980
VALVE GROUP
776, 777
776, 777
4T0952
VALVE GROUP
769C, 772B
769C, 772B
4T8657
VALVE-BAG & GAS
785, 789, 793