2415895 VALVE GP-SOLENOID Caterpillar parts
324D FM, 525C, 535C, 545C, 583T, 587R, 587T, 938H, 950H, 953D, 963D, 973D, D5N, D6K LGP, D6K2, D6K2 LGP, D6N, D7E, D7E LGP, IT38H, PL61
Rating:
Alternative (cross code) number:
CA2415895
241-5895
2415895
CA2415895
241-5895
2415895
Weight: 0.60 pounds 0 kg.
EXCAVATOR, WHEEL SKIDDER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
#US Replacement Part Fits for Kenmore 106.44032601 Refrigerator Ice Maker Control Board icepart#2415895
Generic NOTE - Package included: 1 Set ONLY. Please check all carefully (photos and model) and make sure it will compatible with your original one. || Color: Black. Color: Black || Compatible Model: 106.44032601 || Part Number: 106.44032601
Generic NOTE - Package included: 1 Set ONLY. Please check all carefully (photos and model) and make sure it will compatible with your original one. || Color: Black. Color: Black || Compatible Model: 106.44032601 || Part Number: 106.44032601
Compatible equipment models: 2415895:
Information:
The transfer mechanism must be tested with all power supplies turned OFF. Use a volt-ohm-meter (VOM) for the tests. During the tests the main contacts will be manually actuated to (a) tripped or NEUTRAL position, (b) STANDBY position, and (c) NORMAL position.
: ALL Power must be turned OFF to the transfer switch before attempting manual operation and/or tests. Extremely dangerous - possibly lethal - electrical shock could occur.
In the tests that follow, the actual resistance reading is not given. A specific resistance is not important. Either a small resistance or infinity should be indicated, as specified in the specific test.Tests With Main Contacts At NEUTRAL
Transfer Mechanism Terminal StripTurn OFF all power voltage supplies to the transfer switch. Manually actuate the main contacts to their NEUTRAL (Tripped) position. (See functional tests, manual operation for instructions to manually actuate the transfer mechanism) Verify that the word "OFF" is visible in both power source display windows. To completely check the transfer mechanism when in the NEUTRAL position, perform all the following tests with an ohmmeter.With the main contacts tripped (in NEUTRAL position), connect ohmmeter test probes across transfer mechanism terminals as follows.Closing Coil (C) Continuity And Diode Test
1. Positive test probe at A1, Negative at A2: Meter should indicate a small resistance.2. Positive test probe at A2, Negative at A1: Meter should indicate a small resistance.Selective Coil (SC) Continuity And Diode Test
1. Positive test probe at B1, Negative at B2: Meter should indicate a small resistance.2. Positive test probe at B2, Negative at B1: Meter should indicate a small resistance.Trip Coil Switch (ATS1 and ATS2) Test
1. Positive test probe at AT1, Negative at AT2: Meter
: ALL Power must be turned OFF to the transfer switch before attempting manual operation and/or tests. Extremely dangerous - possibly lethal - electrical shock could occur.
In the tests that follow, the actual resistance reading is not given. A specific resistance is not important. Either a small resistance or infinity should be indicated, as specified in the specific test.Tests With Main Contacts At NEUTRAL
Transfer Mechanism Terminal StripTurn OFF all power voltage supplies to the transfer switch. Manually actuate the main contacts to their NEUTRAL (Tripped) position. (See functional tests, manual operation for instructions to manually actuate the transfer mechanism) Verify that the word "OFF" is visible in both power source display windows. To completely check the transfer mechanism when in the NEUTRAL position, perform all the following tests with an ohmmeter.With the main contacts tripped (in NEUTRAL position), connect ohmmeter test probes across transfer mechanism terminals as follows.Closing Coil (C) Continuity And Diode Test
1. Positive test probe at A1, Negative at A2: Meter should indicate a small resistance.2. Positive test probe at A2, Negative at A1: Meter should indicate a small resistance.Selective Coil (SC) Continuity And Diode Test
1. Positive test probe at B1, Negative at B2: Meter should indicate a small resistance.2. Positive test probe at B2, Negative at B1: Meter should indicate a small resistance.Trip Coil Switch (ATS1 and ATS2) Test
1. Positive test probe at AT1, Negative at AT2: Meter
Cat SIS web machinery list:
Parts valve Caterpillar catalog:
1J8497
VALVE
120G, 12E, 12G, 140, 14E, 14G, 16, 163, 172, 173B, 183, 183B, 191, 225, 245, 307, 312, 315, 317, 325B, 330 L, 350, 350 L, 375, 41, 44, 46, 5080, 517, 518, 518C, 527, 528, 528B, 530B, 561C, 561H, 561M,...
120G, 12E, 12G, 140, 14E, 14G, 16, 163, 172, 173B, 183, 183B, 191, 225, 245, 307, 312, 315, 317, 325B, 330 L, 350, 350 L, 375, 41, 44, 46, 5080, 517, 518, 518C, 527, 528, 528B, 530B, 561C, 561H, 561M,...
1284411
VALVE AS
305.5, 306, 306E, 307B, 307C, 307D, 308C, 308D, 311, 311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 313B, 314C, 314D CR, 314D LCR, 315, 315B, 315B L, 315C, 315D L, 317B LN, 318B, 318C...
305.5, 306, 306E, 307B, 307C, 307D, 308C, 308D, 311, 311B, 311C, 311D LRR, 312B, 312B L, 312C, 312C L, 312D, 312D L, 313B, 314C, 314D CR, 314D LCR, 315, 315B, 315B L, 315C, 315D L, 317B LN, 318B, 318C...
3577540
VALVE-FILL
1290T, 1390, 2491, 2590, 307C, 307D, 307E, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 311C, 311D LRR, 311F LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D...
1290T, 1390, 2491, 2590, 307C, 307D, 307E, 308C, 308D, 308E, 308E CR, 308E SR, 308E2 CR, 311C, 311D LRR, 311F LRR, 312C, 312C L, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 312E, 312E L, 313D, 313D2, 313D...
1908609
VALVE-FILL
517, 527, 561M, 561N, 572R II, 583R, 583T, 587R, 587T, 589, 623G, 933C, 939C, 973D, D10R, D10T, D10T2, D11R, D11T, D3C III, D3G, D3K XL, D3K2 LGP, D4C III, D4G, D4K XL, D4K2 XL, D5C III, D5G, D5HTSK I...
517, 527, 561M, 561N, 572R II, 583R, 583T, 587R, 587T, 589, 623G, 933C, 939C, 973D, D10R, D10T, D10T2, D11R, D11T, D3C III, D3G, D3K XL, D3K2 LGP, D4C III, D4G, D4K XL, D4K2 XL, D5C III, D5G, D5HTSK I...
1349602
VALVE AS-WATER
D5M, D5N, D6G2 LGP, D6G2 XL, D6M, D6N, D6R, D6R II, D6R III, D6R STD, D6T, D7G2, D7R, D7R II, D7R XR, D8R II
D5M, D5N, D6G2 LGP, D6G2 XL, D6M, D6N, D6R, D6R II, D6R III, D6R STD, D6T, D7G2, D7R, D7R II, D7R XR, D8R II
7P7245
VALVE
943, 953, 953B, 953C, 953D, 963, 963B, 963C, 963D, 973, 973C
943, 953, 953B, 953C, 953D, 963, 963B, 963C, 963D, 973, 973C
1074397
VALVE AS
16M, 24M, 5110B, 583T, 587T, 769D, 771D, 773D, 773E, 773F, 775D, 775E, 775F, 776D, 777D, 777F, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795...
16M, 24M, 5110B, 583T, 587T, 769D, 771D, 773D, 773E, 773F, 775D, 775E, 775F, 776D, 777D, 777F, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795...
7M1296
VALVE-RELIEF
572G, 572R, 572R II, 578, 583R, 587R, 587T, D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7F, D7G, D7H, D7R, D7R II, D7R XR, D8H, D8K, D8N, D8R, D9G, PL87
572G, 572R, 572R II, 578, 583R, 587R, 587T, D6H, D6H XL, D6H XR, D6R, D6R II, D6R III, D6R STD, D6T, D6T LGP, D6T LGPPAT, D6T XL, D7F, D7G, D7H, D7R, D7R II, D7R XR, D8H, D8K, D8N, D8R, D9G, PL87
1582336
VALVE-GAS
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 5110B, 5130B, 735, 740, 784C, 785C, 785D, 789C, 793C, 793D, 797, 914G, 924F, 9...
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 5110B, 5130B, 735, 740, 784C, 785C, 785D, 789C, 793C, 793D, 797, 914G, 924F, 9...
2448686
VALVE GP-SOLENOID
120M, 12M, 140M, 14M, 160M, 16M, 938G II, 938H, IT38G II, IT38H, R1300G, R1300G II, R1600G, R1700G
120M, 12M, 140M, 14M, 160M, 16M, 938G II, 938H, IT38G II, IT38H, R1300G, R1300G II, R1600G, R1700G
2200814
VALVE-BREAKER RELIEF
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 5130B, 521, 522, 5230, 5230B, 532, 541, 551, 552, 657G, 824G II, 824H, 825G II, 825H, 826G II, 826H, 938H, 950H, 962H, 966G, 966G II,...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 5130B, 521, 522, 5230, 5230B, 532, 541, 551, 552, 657G, 824G II, 824H, 825G II, 825H, 826G II, 826H, 938H, 950H, 962H, 966G, 966G II,...
2390618
VALVE GP-SHUTTLE
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
2497805
VALVE GP-SHUTTLE
844H, 844K, 854K, D5N, D6N
844H, 844K, 854K, D5N, D6N
2486162
VALVE AS-SHUTTLE
D5N, D6N
D5N, D6N
2315213
VALVE GP-SHUTTLE
D5N, D6N
D5N, D6N
2413974
VALVE GP-CHECK
938H, 973C, IT38H
938H, 973C, IT38H
3920776
VALVE AS-DRAIN
583T, 587T, 814F II, 815F II, 816F II, 824C, 973C, D8R, D8T, PL83, PL87
583T, 587T, 814F II, 815F II, 816F II, 824C, 973C, D8R, D8T, PL83, PL87
2428771
VALVE AS
725, 730, 735, 740, 953C, 963C, 973C
725, 730, 735, 740, 953C, 963C, 973C
2001309
VALVE GP
D3G, D4G, D5G
D3G, D4G, D5G
2027690
VALVE GP-RELIEF
D3G, D4G, D5G
D3G, D4G, D5G
2139083
VALVE GP-ENGINE OIL DRAIN
D3G, D4G, D5G
D3G, D4G, D5G
1248335
VALVE AS-CONTROL
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 583T, 587R, 587T, 657G, 777G, 785D, 924G, 924GZ, 924H, 924HZ, 928H, 928HZ, 930G, D10N, D10R, D5R LGP, D6N, D6N ...
120M 2, 12M 2, 12M 3, 12M 3 AWD, 140M 2, 140M 3, 140M 3 AWD, 160M 2, 160M 3, 160M 3 AWD, 583T, 587R, 587T, 657G, 777G, 785D, 924G, 924GZ, 924H, 924HZ, 928H, 928HZ, 930G, D10N, D10R, D5R LGP, D6N, D6N ...
1805317
VALVE AS-WATER
D5N, D6N
D5N, D6N
3338242
VALVE GP-SOLENOID
2290, 2390, 2391, 2491, 2590, 320D FM, 511, 521, 521B, 522, 522B, 532, 541, 541 2, 545C, 551, 552, 552 2, 583T, 587R, 587T, 613G, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 834K, 836K, 93...
2290, 2390, 2391, 2491, 2590, 320D FM, 511, 521, 521B, 522, 522B, 532, 541, 541 2, 545C, 551, 552, 552 2, 583T, 587R, 587T, 613G, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 834K, 836K, 93...