2461730 VALVE GP-CONTROL Caterpillar parts
RM-300
Rating:
Alternative (cross code) number:
CA2461730
246-1730
2461730
CA2461730
246-1730
2461730
Weight: 4 pounds 1 kg.
RECLAIMER MIXER,
Compatible equipment models: 2461730:
Information:
Increase (4) - Push this switch in order to increase the temperature of the air that is coming out of the air outlets or push this switch in order to increase the preset temperature.
Decrease (5) - Push this switch in order to decrease the temperature of the air that is coming out of the air outlets or push this switch in order to decrease the preset temperature.
Fan Speed Switches - The fan speed switch directly controls the fan speed if only the fan is being operated. If the heating and air conditioning system is operating in the automatic mode, pushing this switch overrides the automatically selected fan speed.
Increase (9) - Push this switch in order to increase the fan speed.
Decrease (8) - Push this switch in order to decrease the fan speed. Air Inlet Selection Switches - These switches select the position of the air inlet.
Recirculate (11) - When this position is selected, the air inlet is closed. The air will recirculate inside the cab.
Fresh Air (10) - When this position is selected, the air inlet is open. Fresh air will circulate into the cab. Note: If the heating and air conditioning system is in the automatic mode at engine start-up and the temperature inside the cab is too warm or too cool, the damper for fresh air ventilation may automatically close for a few minutes. This will help to bring the air temperature to the preset temperature more quickly.Air Outlet Selection Switches - This switch selects the position of each air outlet. Each switch controls a separate air outlet.
Upper Body (15) - Depressing this switch directs the air flow out of air outlet (A) .
Upper Body and Under Seat (14) - Depressing this switch directs the air flow out of air outlet (A) and air outlet (B) .
Under Seat (13) - Depressing this switch directs the air flow out of air outlet (B) .
Defrost (12) - Depressing this switch directs the air flow out of air outlet (A) and air outlet (C) . Preset Temperature Display (6) - This display shows the set temperature.With the display ON, press the temperature selection switch (increase) (4), the temperature selection switch (decrease) (5) and the On/Off switch (1) simultaneously. This will toggle the display between Degrees Celsius and Degrees Fahrenheit.
Air Conditioning Override Switch (3) - If the heating and air conditioning system is in the automatic mode, pushing this switch causes the compressor to run continuously while the compressor tries to maintain the preset temperature. If the heating and air conditioning system is set for operation of the fan only, this switch has no function. The compressor may be operated intermittently during heater operation in order to remove excess humidity from the cab. To cancel this override mode push switch (3) again.
Automatic Temperature Control Switch (2) - Pushing this button causes the heating and air conditioning system to toggle between the mode for automatic temperature control and the mode for the fan only. Note: If the fan speed is manually
Decrease (5) - Push this switch in order to decrease the temperature of the air that is coming out of the air outlets or push this switch in order to decrease the preset temperature.
Fan Speed Switches - The fan speed switch directly controls the fan speed if only the fan is being operated. If the heating and air conditioning system is operating in the automatic mode, pushing this switch overrides the automatically selected fan speed.
Increase (9) - Push this switch in order to increase the fan speed.
Decrease (8) - Push this switch in order to decrease the fan speed. Air Inlet Selection Switches - These switches select the position of the air inlet.
Recirculate (11) - When this position is selected, the air inlet is closed. The air will recirculate inside the cab.
Fresh Air (10) - When this position is selected, the air inlet is open. Fresh air will circulate into the cab. Note: If the heating and air conditioning system is in the automatic mode at engine start-up and the temperature inside the cab is too warm or too cool, the damper for fresh air ventilation may automatically close for a few minutes. This will help to bring the air temperature to the preset temperature more quickly.Air Outlet Selection Switches - This switch selects the position of each air outlet. Each switch controls a separate air outlet.
Upper Body (15) - Depressing this switch directs the air flow out of air outlet (A) .
Upper Body and Under Seat (14) - Depressing this switch directs the air flow out of air outlet (A) and air outlet (B) .
Under Seat (13) - Depressing this switch directs the air flow out of air outlet (B) .
Defrost (12) - Depressing this switch directs the air flow out of air outlet (A) and air outlet (C) . Preset Temperature Display (6) - This display shows the set temperature.With the display ON, press the temperature selection switch (increase) (4), the temperature selection switch (decrease) (5) and the On/Off switch (1) simultaneously. This will toggle the display between Degrees Celsius and Degrees Fahrenheit.
Air Conditioning Override Switch (3) - If the heating and air conditioning system is in the automatic mode, pushing this switch causes the compressor to run continuously while the compressor tries to maintain the preset temperature. If the heating and air conditioning system is set for operation of the fan only, this switch has no function. The compressor may be operated intermittently during heater operation in order to remove excess humidity from the cab. To cancel this override mode push switch (3) again.
Automatic Temperature Control Switch (2) - Pushing this button causes the heating and air conditioning system to toggle between the mode for automatic temperature control and the mode for the fan only. Note: If the fan speed is manually
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
2812725
VALVE GP-CHECK
140H, 143H, 14H, 14M, 160H, 163H, 16H, 16M, 24M, 3176C, 3196, 3406E, 3456, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 365B, 365B II, 365B L, 365C,...
140H, 143H, 14H, 14M, 160H, 163H, 16H, 16M, 24M, 3176C, 3196, 3406E, 3456, 345B, 345B II, 345B II MH, 345B L, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 365B, 365B II, 365B L, 365C,...
8C3446
VALVE-FLUID SAMPLING
1090, 1190, 1190T, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 1390, 140B, 140G, 140H, 140H ES, 1...
1090, 1190, 1190T, 120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 1390, 140B, 140G, 140H, 140H ES, 1...
6V7238
VALVE-SHUTOFF
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
1645590
VALVE GP-FLUID SAMPLING
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12K, 135H, 135H NA, 1390, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 216B, 216B3, 226B, 226B3, 2290, 232B, 236B, 236B3, ...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 1290T, 12H, 12K, 135H, 135H NA, 1390, 140H, 140K, 140K 2, 143H, 14H, 160H, 160K, 163H, 16H, 216B, 216B3, 226B, 226B3, 2290, 232B, 236B, 236B3, ...
1090897
VALVE-BALL
24M, 311F LRR, 374F L, AP1000E, AP1055E, AP555E, BG1000E, BG1055E, BG500E, C175-16, C27, C32, RM-300, RM-500
24M, 311F LRR, 374F L, AP1000E, AP1055E, AP555E, BG1000E, BG1055E, BG500E, C175-16, C27, C32, RM-300, RM-500
2243028
VALVE-INLET
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 349D L, 725, 730, 966H, 972H, C11, C13, C13 XQ350, CX31-C13I, D8N, R1700G, RM-300, TH35-C13I, W345C MH
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 349D L, 725, 730, 966H, 972H, C11, C13, C13 XQ350, CX31-C13I, D8N, R1700G, RM-300, TH35-C13I, W345C MH
2243030
VALVE-EXHAUST
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 725, 730, 966H, 972H, 980C, C11, C13, C13 XQ350, CX31-C13I, D8N, R1600H, R1700G, RM-300, TH35-C11I, TH35-C13I, W345C MH
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 725, 730, 966H, 972H, 980C, C11, C13, C13 XQ350, CX31-C13I, D8N, R1600H, R1700G, RM-300, TH35-C11I, TH35-C13I, W345C MH
2527802
VALVE-INLET
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725, 730, 730C, 966H, 972H,...
14M, 16M, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 349E, 349E L, 349E L HVG, 349E L VG, 349F L, 621H, 621K, 623H, 623K, 623K LRC, 627H, 627K, 627K LRC, 725, 730, 730C, 966H, 972H,...
9U4537
VALVE GP-TIRE
834B, 844, 844H, 844K, 980C, 980F, 980F II, 988B, 988F, 988F II, 990, 990 II, 990H, 990K, AD55, AD55B, AD60, R2900G, R3000H, RM-300, RM-350B, RM-500
834B, 844, 844H, 844K, 980C, 980F, 980F II, 988B, 988F, 988F II, 990, 990 II, 990H, 990K, AD55, AD55B, AD60, R2900G, R3000H, RM-300, RM-350B, RM-500
2541556
VALVE & MTG GP-BANK
RM-300
RM-300
2502990
VALVE & MTG GP-CONTROL
AP-800D
AP-800D
2781669
VALVE GP-FLUSHING
CB-334E, CB-34
CB-334E, CB-34
2172753
VALVE MECHANISM GP
216, 216B, 232B, 242B, 3024C, C2.2, CB-334E
216, 216B, 232B, 242B, 3024C, C2.2, CB-334E
3520514
VALVE GP-FLOW DIVIDER
BG-260D
BG-260D
2309389
VALVE GP-FLOW DIVIDER
BG-260D
BG-260D
2326222
VALVE & MTG GP-CONTROL
AP-1000B
AP-1000B
2492440
VALVE GP-BRAKE CONTROL
PF-300C
PF-300C
2612299
VALVE GP-MODULATING
PF-300C
PF-300C
2566779
VALVE GP-PUMP CONTROL
CW-14, PS-150C
CW-14, PS-150C
2327423
VALVE & MTG GP-TRUCK HITCH
AP-1055D, BG-2455D
AP-1055D, BG-2455D