2464612 VALVE-AIR CLEANER DUST Caterpillar parts
525C, 535C, 545C, 815B, 950 GC, 950H, 962H, 966H, 972H, IT62H
Rating:
Alternative (cross code) number:
CA2464612
246-4612
2464612
CA2464612
246-4612
2464612
Weight: 0.20 pounds 0 kg.
INTEGRATED TOOLCARRIER, WHEEL SKIDDER,
Compatible equipment models: 2464612:
Information:
Standard Motor
Illustration 1 g03796062
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Engine (12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (17) Tank
Illustration 2 g03789601
(12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Outlet (20) InletThe speed of the fan is controlled by demand fan solenoid valve (16) . The demand fan solenoid valve is controlled by the machine ECM. The speed of the fan motor depends on the amount of flow that is allowed through valve (16) for the fan. The control of the fan speed is based on the value of the following conditions:
Inlet manifold temperature
Transmission oil temperature
Hydraulic oil temperature
Engine coolant temperature
Ambient temperature (if the air conditioning is on)The machine ECM may require more air flow for cooling. If so, the machine ECM will decrease the amount of electric current sent to demand fan solenoid valve (16) . This decrease will close the demand fan solenoid valve. When the demand fan solenoid valve closes more, the pressure of pilot oil acting on flow control valve (23) for the fan increases. This action restricts the flow of oil through the flow control valve for the fan. Restricted oil flow through the flow control valve causes oil from the braking and hydraulic fan pump (10) to flow through fan motor (12) . The fan motor will turn faster. The speed of the fan depends on the following inputs:
The amount of current that is sent to the demand fan solenoid valve
The amount of pump flow that is availableThe machine ECM may not require more air flow for cooling. If so, the machine ECM will increase the amount of electric current to the demand fan solenoid valve. This increase will shift the demand fan solenoid valve more open. This action will increase the flow of oil through the flow control valve for the fan. Increased results in less oil flowing to the fan motor. The fan motor will turn more slowly. The speed of the fan depends on the amount of current that is sent to the demand fan solenoid valve.Makeup valve (15) prevents cavitation of the fan motor during deceleration.From the fan motor, hydraulic oil flows directly back to the hydraulic oil tank.Reversing Motor
Illustration 3 g03789688
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Motor and Pump Stack (13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (17) Tank (21) Reversing Fan Motor
Illustration 4 g03789623
(13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Inlet (20) Outlet (21) Fan MotorThe machine can be equipped with a reversing fan. The cooling capacity of the
Illustration 1 g03796062
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Engine (12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (17) Tank
Illustration 2 g03789601
(12) Standard Fan Motor (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Outlet (20) InletThe speed of the fan is controlled by demand fan solenoid valve (16) . The demand fan solenoid valve is controlled by the machine ECM. The speed of the fan motor depends on the amount of flow that is allowed through valve (16) for the fan. The control of the fan speed is based on the value of the following conditions:
Inlet manifold temperature
Transmission oil temperature
Hydraulic oil temperature
Engine coolant temperature
Ambient temperature (if the air conditioning is on)The machine ECM may require more air flow for cooling. If so, the machine ECM will decrease the amount of electric current sent to demand fan solenoid valve (16) . This decrease will close the demand fan solenoid valve. When the demand fan solenoid valve closes more, the pressure of pilot oil acting on flow control valve (23) for the fan increases. This action restricts the flow of oil through the flow control valve for the fan. Restricted oil flow through the flow control valve causes oil from the braking and hydraulic fan pump (10) to flow through fan motor (12) . The fan motor will turn faster. The speed of the fan depends on the following inputs:
The amount of current that is sent to the demand fan solenoid valve
The amount of pump flow that is availableThe machine ECM may not require more air flow for cooling. If so, the machine ECM will increase the amount of electric current to the demand fan solenoid valve. This increase will shift the demand fan solenoid valve more open. This action will increase the flow of oil through the flow control valve for the fan. Increased results in less oil flowing to the fan motor. The fan motor will turn more slowly. The speed of the fan depends on the amount of current that is sent to the demand fan solenoid valve.Makeup valve (15) prevents cavitation of the fan motor during deceleration.From the fan motor, hydraulic oil flows directly back to the hydraulic oil tank.Reversing Motor
Illustration 3 g03789688
(1) Keypad module (2) CAN data link (3) Engine Control Module (ECM) (4) To Brake System (5) Shuttle Valve (6) Sensor (7) Cut-in/Cut-out Valve (8) Relief Valve (9) Priority Valve (10) Charge Pump (11) Motor and Pump Stack (13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (17) Tank (21) Reversing Fan Motor
Illustration 4 g03789623
(13) Cross-over Relief Valve (14) Reversing Fan Solenoid Valve (if equipped) (15) Check Valve (16) Fan Solenoid Valve (18) Case Drain (19) Inlet (20) Outlet (21) Fan MotorThe machine can be equipped with a reversing fan. The cooling capacity of the
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
1491997
VALVE AS-RELIEF
120G, 12G, 130G, 140G, 14G, 16G, 3516B, 5110B, 5130, 5130B, 5230, 5230B, 627E, 651E, 657E, 773B, 776C, 776D, 777, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 793B, 793C, 815B, 826C, 980C, 988B, 99...
120G, 12G, 130G, 140G, 14G, 16G, 3516B, 5110B, 5130, 5130B, 5230, 5230B, 627E, 651E, 657E, 773B, 776C, 776D, 777, 777D, 784B, 784C, 785B, 785C, 785D, 789B, 789C, 793B, 793C, 815B, 826C, 980C, 988B, 99...
5P7090
VALVE-BALL
227, 229D, 322C, 325B L, 518, 528, 528B, 530B, 561D, 589, 615, 615C, 621, 621B, 621R, 623E, 627B, 637E, 651E, 657E, 814, 814B, 815, 815B, 910, 931B, 943, 950, 953, 966C, 966D, 966R, 977K, 977L, 980B, ...
227, 229D, 322C, 325B L, 518, 528, 528B, 530B, 561D, 589, 615, 615C, 621, 621B, 621R, 623E, 627B, 637E, 651E, 657E, 814, 814B, 815, 815B, 910, 931B, 943, 950, 953, 966C, 966D, 966R, 977K, 977L, 980B, ...
1074397
VALVE AS
16M, 24M, 5110B, 583T, 587T, 769D, 771D, 773D, 773E, 773F, 775D, 775E, 775F, 776D, 777D, 777F, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795...
16M, 24M, 5110B, 583T, 587T, 769D, 771D, 773D, 773E, 773F, 775D, 775E, 775F, 776D, 777D, 777F, 785, 785B, 785C, 785D, 789, 789B, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795...
1582336
VALVE-GAS
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 5110B, 5130B, 735, 740, 784C, 785C, 785D, 789C, 793C, 793D, 797, 914G, 924F, 9...
120M, 120M 2, 12M, 12M 2, 12M 3, 12M 3 AWD, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 5110B, 5130B, 735, 740, 784C, 785C, 785D, 789C, 793C, 793D, 797, 914G, 924F, 9...
3V8313
VALVE AS-BRAKE CONTROL
528, 611, 613C, 613C II, 615, 615C, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 631E, 633E II, 637E, 639D, 651E, 657E, 815B, 826C, 916, 926, 936, 950B, 950F, 950F II, 960F, 966D, 966F, 966F II, 970F, 98...
528, 611, 613C, 613C II, 615, 615C, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 631E, 633E II, 637E, 639D, 651E, 657E, 815B, 826C, 916, 926, 936, 950B, 950F, 950F II, 960F, 966D, 966F, 966F II, 970F, 98...
1K8374
VALVE GP-TIRE
611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 950 GC, AP-1000, AP-1000B, AP-600D, AP-800C, AP-800D, AP-900B, AP1000E, BG-225B, BG-260D, BG1000E, BG600D, D...
611, 613, 613B, 613C, 613C II, 613G, 615, 615C, 725, 725C, 730, 730C, 735, 735B, 740, 740B, 950 GC, AP-1000, AP-1000B, AP-600D, AP-800C, AP-800D, AP-900B, AP1000E, BG-225B, BG-260D, BG1000E, BG600D, D...
8M3368
VALVE-CHECK
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 1...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 130G, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14G, 14H NA, 14M, 160G, 160H, 160H ES, 160H NA, 1...
3D2239
VALVE AS-TIRE
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 160H, 160K, 160M...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 130G, 135H, 135H NA, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 140M 3, 160H, 160K, 160M...
2200814
VALVE-BREAKER RELIEF
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 5130B, 521, 522, 5230, 5230B, 532, 541, 551, 552, 657G, 824G II, 824H, 825G II, 825H, 826G II, 826H, 938H, 950H, 962H, 966G, 966G II,...
1090, 1190, 1190T, 1290T, 1390, 2290, 2390, 2391, 2491, 2590, 511, 5130B, 521, 522, 5230, 5230B, 532, 541, 551, 552, 657G, 824G II, 824H, 825G II, 825H, 826G II, 826H, 938H, 950H, 962H, 966G, 966G II,...
2390618
VALVE GP-SHUTTLE
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
2824349
VALVE GP-PRESSURE REDUCING
950H, 962H, 966H, 972H, IT62H
950H, 962H, 966H, 972H, IT62H
4D1138
VALVE
120G, 120H, 12G, 12H, 12H NA, 130G, 135H, 140G, 140H, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 163H, 16G, 16H, 16H NA, 5110B, 518, 5230, 5230B, 528, 621B, 631C, 633C, 639D, 666, 769, 769C, 769D, 7...
120G, 120H, 12G, 12H, 12H NA, 130G, 135H, 140G, 140H, 140H NA, 143H, 14G, 14H, 14H NA, 160G, 160H, 163H, 16G, 16H, 16H NA, 5110B, 518, 5230, 5230B, 528, 621B, 631C, 633C, 639D, 666, 769, 769C, 769D, 7...
2086678
VALVE-CHECK
120H, 12H, 135H, 140H, 143H, 160H, 163H, 16H, 631G, 637G
120H, 12H, 135H, 140H, 143H, 160H, 163H, 16H, 631G, 637G
3866210
VALVE AS-BALL
627G, 637D, 637E, 637G
627G, 637D, 637E, 637G
2055363
VALVE
621G, 623G, 627G, 631G, 637G, 740, 740B, 990K, D400E II
621G, 623G, 627G, 631G, 637G, 740, 740B, 990K, D400E II
4404715
VALVE GP-SOLENOID
621G, 627G, 631G, 637G
621G, 627G, 631G, 637G
3089433
VALVE GP-CHECK
2290, 2390, 2391, 2491, 2864C, 511, 521, 521B, 522, 522B, 532, 586C, 621G, 621H, 623G, 623H, 627G, 627H, 631G, 637G, 657G, BG-260D
2290, 2390, 2391, 2491, 2864C, 511, 521, 521B, 522, 522B, 532, 586C, 621G, 621H, 623G, 623H, 627G, 627H, 631G, 637G, 657G, BG-260D
3422410
VALVE GP-SOLENOID
621G, 623G, 627G, 631G, 637G, 657G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
621G, 623G, 627G, 631G, 637G, 657G, 770, 770G, 770G OEM, 772, 772G, 772G OEM, 773F, 773G, 773G LRC, 773G OEM, 775F, 775G, 775G LRC, 775G OEM, 777F, 777G
2824349
VALVE GP-PRESSURE REDUCING
950H, 962H, 966H, 972H, IT62H
950H, 962H, 966H, 972H, IT62H
3565129
VALVE GP-PRIORITY
950H, 962H, 966H, 972H, IT62H
950H, 962H, 966H, 972H, IT62H
2390618
VALVE GP-SHUTTLE
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
120M, 12M, 140M, 14M, 160M, 16M, 24M, 725, 725C, 730, 730C, 938H, 950H, 962H, 966H, 972H, IT38H, IT62H
2390621
VALVE GP-DIVERTER
725, 730, 950H, 962H, 966H, 972H, IT62H
725, 730, 950H, 962H, 966H, 972H, IT62H
3537179
VALVE GP-CHECK
950H, 962H, 966H, 972H, 980M, D10T2, IT62H
950H, 962H, 966H, 972H, 980M, D10T2, IT62H
3075393
VALVE GP-CHECK
950 GC, 950H, 962H, 966H, 972H, 980C, IT62H
950 GC, 950H, 962H, 966H, 972H, 980C, IT62H