The values in Table 12 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 12
Rated Voltage     24 VDC    
Coil Resistance     32.0 3.2Ω (T=20° C)    The On/Off solenoids include:
Swing brake solenoid
Travel speed solenoid
Straight travel solenoid
Hydraulic lock solenoid
Swing priority solenoidProportional Reducing Solenoid Valve
Illustration 22 g02703776
The values in Table 13 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 13
Current Range     0 mA ~ 700 mA    
Coil Resistance     11.5 0.5Ω (T=20° C)    
Illustration 23 g02263554
A - Port pressure (kPa) vs Current (mA)The proportional reducing solenoid valve is used on machines equipped with tool control. The P-Port is blocked and does not allow pressure to the A-port. Therefore, the machine ECM must apply current to the PRV in order to sent pressure to the A-port of the PRV.Reverse Proportional Reducing Solenoid Valve
Illustration 24 g02304374
Valve cutaway, hydraulic schematic symbol, and electrical connector designationThe values in Table 14 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 14
Current Range     0 mA ~ 700 mA    
Coil Resistance     11.5 0.5Ω (T=20° C)    
Illustration 25 g02304414
Reverse PRV's have the P-port open to the A-port with no current applied. Therefore, the machine ECM applies current to the PRV in order to decrease the pressure at the A-port. The reverse PRV's include:
Boom Regeneration PRVESP Pump Solenoid Valve
Illustration 26 g03236478
The values in Table 15 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 15
Rated Voltage     24 V    
Coil Resistance     5 0.3Ω (T=25° C)
5 0.3Ω (T=25° C)    The ESP pump solenoid valve is located on the drive pump and idler pump regulators. The solenoid valve controls the horsepower control spool in the pump regulator. Current of 1 amp maintains the spool in the neutral position and cannot be adjusted. Data Link
Cat Data Link
Illustration 27 g02694217
Schematic of the "Cat Data Link" CircuitThe Cat Data Link is an input and an output of the Machine ECM. The Cat Data Link connects to the Machine ECM at connector contact J2-16 and J2-25. The data link is designed to carry communications between the controller and the monitor. The data link is not a visible component. The data link consists of internal control circuits and a harness wiring. The data link is bidirectional. The controller can receive information and the controller can send information through the data link. The controller sends information about the fuel level, temperature of the engine coolant, and many other signals to the monitor panel.CAN Data Link
Illustration 28 g02694576
Schematic of the "CAN Data Link" CircuitThe CAN data link is used for communication between the following modules: Machine ECM, Switch Panel and Monitor. Two 120 Ohm terminating resistors must be installed in the wiring harness in order for the CAN data link to function properly.Action Alarm
The action alarm SOUNDS in order to alert the operator when a high emergency condition is present. For example, the engine oil pressure decreases
Table 12
Rated Voltage     24 VDC    
Coil Resistance     32.0 3.2Ω (T=20° C)    The On/Off solenoids include:
Swing brake solenoid
Travel speed solenoid
Straight travel solenoid
Hydraulic lock solenoid
Swing priority solenoidProportional Reducing Solenoid Valve
Illustration 22 g02703776
The values in Table 13 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 13
Current Range     0 mA ~ 700 mA    
Coil Resistance     11.5 0.5Ω (T=20° C)    
Illustration 23 g02263554
A - Port pressure (kPa) vs Current (mA)The proportional reducing solenoid valve is used on machines equipped with tool control. The P-Port is blocked and does not allow pressure to the A-port. Therefore, the machine ECM must apply current to the PRV in order to sent pressure to the A-port of the PRV.Reverse Proportional Reducing Solenoid Valve
Illustration 24 g02304374
Valve cutaway, hydraulic schematic symbol, and electrical connector designationThe values in Table 14 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 14
Current Range     0 mA ~ 700 mA    
Coil Resistance     11.5 0.5Ω (T=20° C)    
Illustration 25 g02304414
Reverse PRV's have the P-port open to the A-port with no current applied. Therefore, the machine ECM applies current to the PRV in order to decrease the pressure at the A-port. The reverse PRV's include:
Boom Regeneration PRVESP Pump Solenoid Valve
Illustration 26 g03236478
The values in Table 15 are for bench testing only. Values may not represent parameters for machine systems specifications.
Table 15
Rated Voltage     24 V    
Coil Resistance     5 0.3Ω (T=25° C)
5 0.3Ω (T=25° C)    The ESP pump solenoid valve is located on the drive pump and idler pump regulators. The solenoid valve controls the horsepower control spool in the pump regulator. Current of 1 amp maintains the spool in the neutral position and cannot be adjusted. Data Link
Cat Data Link
Illustration 27 g02694217
Schematic of the "Cat Data Link" CircuitThe Cat Data Link is an input and an output of the Machine ECM. The Cat Data Link connects to the Machine ECM at connector contact J2-16 and J2-25. The data link is designed to carry communications between the controller and the monitor. The data link is not a visible component. The data link consists of internal control circuits and a harness wiring. The data link is bidirectional. The controller can receive information and the controller can send information through the data link. The controller sends information about the fuel level, temperature of the engine coolant, and many other signals to the monitor panel.CAN Data Link
Illustration 28 g02694576
Schematic of the "CAN Data Link" CircuitThe CAN data link is used for communication between the following modules: Machine ECM, Switch Panel and Monitor. Two 120 Ohm terminating resistors must be installed in the wiring harness in order for the CAN data link to function properly.Action Alarm
The action alarm SOUNDS in order to alert the operator when a high emergency condition is present. For example, the engine oil pressure decreases
Parts valve Caterpillar catalog:
2953437
VALVE GP-
Caterpillar
Caterpillar
2953372
VALVE-
Caterpillar
Caterpillar
2953370
VALVE GP-LOAD
Caterpillar
Caterpillar
2952776
VALVE AS
Caterpillar
Caterpillar
2951250
VALVE GP-DVTR
Caterpillar
Caterpillar
2951249
VALVE GP-SOL
Caterpillar
Caterpillar
2957732
VALVE GP-TEST
Caterpillar
Caterpillar
2956642
VALVE GP-
Caterpillar
Caterpillar
2956641
VALVE GP-
Caterpillar
Caterpillar
2954688
VALVE GP-
Caterpillar
Caterpillar
2953467
VALVE-CHECK
Caterpillar
Caterpillar
2953459
VALVE GP-SOL
Caterpillar
Caterpillar