3958053 VALVE GP-SOLENOID & MANIFOLD Caterpillar parts
MH3037, MH3049, MH3059
Rating:
Alternative (cross code) number:
CA3958053
395-8053
3958053
CA3958053
395-8053
3958053
Weight: 1 pounds 0 kg.
MATERIAL HANDLER,
Information:
Illustration 6 g03424726
Inverter Cabinet Low Voltage compartments for the Motor ECMs
At the Inverter Cabinet. Remove the compartment covers (1) and (2) for the low voltage compartment that contains the motor control ECMs and the interface modules.
At the Motor 1 ECM, disconnect the J1 harness wiring connector from the ECM.
At the Motor 2 ECM, disconnect the J1 harness wiring connector from the ECM.
At the Motor 1 ECM harness connector J1, measure the resistance between the sensor positive (+) contact J1-12 (wire RTDM1-4P-BK) and a good cabinet ground point. Measure the resistance between the sensor positive (+) contact J1-12 and all of the other circuit contacts that are used in the J1 harness connector.
Measure the resistance between the Motor 1 ECM positive (+) contact J1-12 (wire RTDM1-4P-BK) and all of the other circuit contacts that are used in the Motor 2 ECM J1 harness connector.
Repeat this resistance measurement between each of the temperature sensor negative circuits, cabinet ground, and all of the other circuits that are used in the J1 connectors for the Motor 1 ECM and the Motor 2 ECM.Expected Result:At the ECM J1 connectors, each of the resistance measurements between the temperature sensor circuits, cabinet ground, and all of the other circuits that are used in both motor control ECM J1 connectors are greater than 4000 ohms.Results:
OK - Each individual resistance measurement is greater than 4000 ohms. The resistance measurements are indicating that the temperature sensor circuits are not shorted to cabinet ground or to any other circuit that is used in the ECM J1 connectors. Proceed to the Test Step 5.
NOT OK - At least one or more of the resistance measurements between the temperature sensor circuits, cabinet ground, or another circuit is much less than 4000 ohms. The low resistance between the circuits is indicating that there is a short circuit between one of the temperature sensor circuits and either frame ground or another circuit.Repair: The motor bearing temperature sensor connection diagram at the beginning of this procedure shows all of the circuit connections that are in the Inverter Cabinet. For complete machine harness and connector information in the circuits between the cabinet connectors and the temperature sensor in the rear axle housing, refer to the complete machine electrical system schematic.Check the connectors that are used in the circuits for any contamination, damage, or other conditions that could cause a short circuit.Examine the wiring harness that contains the suspect circuits that are indicating the low resistance measurement. Look for areas where the wire insulation could be worn or damaged. Damaged insulation can allow contact with the Inverter Cabinet frame or the machine frame.Locate and examine all of the circuit connections that are used in the suspected sections of the temperature sensor circuit. Check each wire section between connectors for a short circuit.Repair the machine harness or replace the machine harness. STOPTest Step 5. CHECK THE STATUS OF THE DIAGNOSTIC CODE
Inspect the harness wiring connectors for the ECM and the phase module that are disconnected. Clean the contacts
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
6V7238
VALVE-SHUTOFF
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
1090, 1190, 1190T, 120K, 120K 2, 120M, 120M 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 1390, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M, 160M 2, 160M 3, 160M 3 AWD, 16M, 214B, 2...
2457837
VALVE AS-EXPANSION
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
307D, 311D LRR, 311F LRR, 312D, 312D L, 312D2, 312D2 GC, 312D2 L, 313D, 313D2, 313D2 LGP, 315D L, 318D L, 318D2 L, 319D, 319D L, 319D LN, 320D, 320D FM, 320D FM RR, 320D GC, 320D L, 320D LN, 320D LRR,...
2221539
VALVE AS-CHECK
MH3037, MH3049, MH3059, RM-300, RM-350B, RM-500
MH3037, MH3049, MH3059, RM-300, RM-350B, RM-500
4400255
VALVE GP-CHECK
MH3037, MH3049
MH3037, MH3049
4363153
VALVE GP-CONTROL
MH3049
MH3049
3957332
VALVE GP-QUICK-DROP
MH3059
MH3059
3959971
VALVE-CHECK
MH3037, MH3049, MH3059
MH3037, MH3049, MH3059
3959970
VALVE-CHECK
MH3037, MH3049, MH3059
MH3037, MH3049, MH3059
3959969
VALVE GP-SOLENOID
MH3037, MH3049, MH3059
MH3037, MH3049, MH3059
3958773
VALVE GP-LOAD CONTROL
MH3037, MH3049
MH3037, MH3049
3955226
VALVE AS-HYDRAULIC
MH3037
MH3037
3955225
VALVE AS-HYDRAULIC
MH3037
MH3037
4373266
VALVE GP-SOLENOID
MH3037, MH3049
MH3037, MH3049
4373265
VALVE GP-SOLENOID
MH3037, MH3049
MH3037, MH3049
4373256
VALVE GP-RELIEF
MH3037, MH3049
MH3037, MH3049
3958638
VALVE-BALL
MH3037, MH3049, MH3059
MH3037, MH3049, MH3059
3958637
VALVE-BALL
MH3037, MH3049
MH3037, MH3049
3958691
VALVE-CHECK
MH3037
MH3037