VALVE GP-SOLENOID 4215425 - Caterpillar



4215425 VALVE GP-SOLENOID Caterpillar parts 257D, 272D, 272D XHP, 299D, 299D XHP
Rating:
53
Alternative (cross code) number:
CA4215425
421-5425
4215425
Caterpillar 4215425 VALVE GP-SOLENOID
Weight: 0.47 pounds 0 kg.

Buy VALVE GP-SOLENOID 4215425 Caterpillar genuine, new aftermarket tractor parts with delivery
COMPACT TRACK LOADER, SKID STEER LOADER,

Compatible equipment models: 4215425:

COMPACT TRACK LOADER  299D   299D XHP  
MULTI TERRAIN LOADER  257D  
SKID STEER LOADER  272D   272D XHP   Caterpillar
Number on catalog scheme:
  For full view, you need register

Caterpillar parts catalog:

Caterpillar parts catalog
257D Multi Terrain Loader D5T00001-UP (MACHINE) POWERED BY C3.3B Engine
279D Compact Track Loader GTL00001-UP (MACHINE) POWERED BY C3.3B Engine
289D Compact Track Loader TAW00001-UP (MACHINE) POWERED BY C3.3B Engine
279D Compact Track Loader PPT00001-UP (MACHINE) POWERED BY C3.3B Engine
289D Compact Track Loader A9Z00001-UP (MACHINE) POWERED BY C3.3B Engine
257D Multi Terrain Loader EML00001-UP (MACHINE)
279D Compact Track Loader Military WEF00001-UP (MACHINE) POWERED BY C3.3B Engine


Information:


Illustration 1 g01969453
Schematic of the rear axle oil temperature sensor
Sales model 854K\992K
This diagnostic code is associated with the rear axle oil temperature sensor. This diagnostic code is recorded when the ECM reads the signal from the sensor (wire 446-PU(Purple)) as being shorted to ground. The sensor produces a PWM signal. The sensor signal wire (446-PU(Purple)) connects to contact J1-37 of the ECM.The possible causes of this diagnostic code are listed:
The signal circuit (wire 446-PU(Purple)) is shorted to ground.
The sensor has failed.
The ECM has failed. This is unlikely.Note: The test step “CHECK THE SENSOR” can create numerous related diagnostic codes. The related diagnostic codes will be shown as being not active, after all of the harnesses have been reconnected. Clear all related diagnostic codes after this procedure is completed.Test Step 1. CHECK THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Ensure that the diagnostic code is active.
Observe the status of the diagnostic code. Then, disconnect the sensor from the machine harness. Expected Result:The diagnostic code remains active. When the sensor is unplugged the diagnostic changes to an FMI 03.Results:
OK - The diagnostic code is no longer active. The machine harness and the ECM are operating properly. Proceed to test step 2.
NOT OK - The diagnostic code remains active. The sensor has not failed. The machine harness may have failed or the ECM may have failed. Proceed to Test Step 2.Test Step 2. CHECK THE SIGNAL CIRCUIT FOR A SHORT TO GROUND.
The sensor remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the J1 machine harness connector from the ECM.
At the J1 machine harness connector, measure the resistance from contact J1-37 (wire 446-PU(Purple)) to ground. Expected Result:The resistance is greater than 5000 ohms.Results:
OK - The resistance is greater than 5000 ohms.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Module - Replace".STOP
NOT OK - The resistance is less than 5000 ohms.Repair: The machine harness has failed. There is a short in the machine harness between the signal circuit and ground. Repair the machine harness or replace the machine harness.STOP

Parts valve Caterpillar catalog:

2855240 VALVE GP-PUMP CONTROL
246D, 24M, 262D, 272D, 277D, 279D, 287D, 289D, 299D, 414E, 416E, 422E, 424B, 428E, 434E, C11, C13, C15, C18, C27, C32, C9, C9.3, CX31-C13I, CX31-C15I, CX31-C18I, CX31-C9I, CX35-C18I, CX35-P800, D5R LG...
1121817 VALVE GP-MANUAL
216, 216B, 216B3, 226B, 226B3, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 2470C, 247B, 247B3, 252B, 252B3, 256C, 2570C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 2670C, 267B, 268B...
2245152 VALVE-GAS
120H, 12H, 12M 2, 135H, 140H, 143H, 14H, 160H, 163H, 16H, 236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 414E, 416C, 416D, 4...
1129717 VALVE-DUST
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 247, 247B, 247B3, 248, 252B, 252B3, 256C, 257B, 257B3, 257D, 259B3, 259D, 262C, 262C2, 262D, 267, 267B,...
1508599 VALVE AS-TIRE
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 246C, 246D, 248, 252B, 252B3, 256C, 262C, 262C2, 262D, 268B, 272C, 272D, 272D XHP, 904B, 904H
2289240 VALVE GP-RELIEF
216, 216B, 216B3, 226B, 226B3, 228, 232B, 236, 236B, 236B3, 236D, 242B, 242B3, 242D, 247, 247B, 247B3, 248, 252B, 252B3, 257B, 257B3, 257D, 259B3, 259D, 267, 267B, 268B, 272C, 287, 297C, 299C, 906H, 9...
3283317 VALVE AS-WATER
236D, 242D, 246C, 246D, 256C, 257D, 259D, 262C, 262C2, 262D, 272C, 272D, 272D XHP, 277C, 277C2, 277D, 279C, 279C2, 279D, 287C, 287C2, 287D, 289C, 289C2, 289D, 297C, 299C, 299D, 299D XHP
3484593 VALVE GP-CHECK
262D, 272D, 272D XHP, 277D, 279D, 2864C, 299D, 299D XHP, 450E, 450F, 525D, 535D, 545D, 555D, 586C, 824K, 825K, 826K, 924K, 930K, 938K, D3G, D4G, D5G
3895135 VALVE-INLET
272D, 272D XHP, 299D, 299D XHP, 910K, 914K
3453623 VALVE AS-CHECK
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 910K, 914K
1549023 VALVE-SAMPLING
1090, 1190, 1190T, 120H, 120K, 120K 2, 1290T, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 135H, 1390, 140G, 140K, 140K 2, 140M, 140M 2, 140M 3, 140M 3 AWD, 14M, 160K, 160M 2, 160M 3, 160M 3 AWD, 16M, 236D, 242...
3890696 VALVE-EXHAUST
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E, 308E CR, 308E SR, 308E2 CR, 906H2, 907H2, 908H2
4372831 VALVE AS-CHECK
236D, 242D, 257D, 259D, 906H2, 907H2
4372830 VALVE GP-MAKEUP
236D, 242D, 257D, 259D, 906H2, 907H2
4360849 VALVE AS
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E2 CR
3887477 VALVE
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 308E, 308E CR, 308E SR, 906H2, 907H2, 908H2
3979975 VALVE AS
236D, 242D, 246D, 257D, 259D, 262D, 277D, 279D, 287D, 289D, 906H2, 907H2, 908H2
6V2611 VALVE
120B, 120G, 130G, 140B, 140G, 14G, 1673C, 225, 225D, 227, 231D, 3114, 3116, 3208, 3304, 3306, 3306B, 3406B, 450F, 518, 528, 561D, 613C, 613C II, 627B, 637D, 770, 772, 815, 824C, 824G II, 825G II, 826G...
4251600 VALVE GP-SOLENOID
262D, 272D XHP, 277D, 279D, 299D, 299D XHP
3736956 VALVE GP-CONTROL
246D, 262D, 272D, 277D, 279D, 287D, 289D, 299D
2179060 VALVE AS-FLUID SAMPLING
12M, 140M, 14M, 16M, 246D, 262D, 277D, 279D, 345C, 345C L, 345C MH, 345D, 345D L, 345D L VG, 349D, 349D L, 365C, 365C L, 365C L MH, 374D L, 385C, 385C FS, 385C L, 385C L MH, 390D, 390D L, 561N, 586C, ...