Information:
short circuit is a failure of an electrical circuit that results in undesired electrical current. Usually, a short circuit is a bypass of the circuit across a load. For example, a short across the wires in a circuit for a lamp produces too much current in the wires but no current is felt at the lamp. The lamp is shorted out. The resistance in a normal circuit can vary, but the resistance between a particular circuit and other unrelated circuits is always greater than 5000 ohms. The following procedure explains the test for a short circuit:Reference: For a complete electrical schematic, refer to Electrical System Schematic for the genset that is being serviced.TEST FOR A SHORT CIRCUIT.
Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the genset to identify the circuits.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the component and the ECM from the wiring harness.
At the harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
Use the other multimeter probe to check the resistance across all other contacts in the connector(s) of the ECM and frame ground. Expected Result: The resistance is greater than 5000 ohms for all the measurements.OK - The resistance is greater than 5000 ohms for all of the measurements. The harness circuits are correct.Stop. NOT OK - The resistance is less than 5000 ohms. There is a short in the harness of the generator set. The short is between the suspect wire and the wire with the lowest resistance measurement.Repair: Repair the harness of the generator set or replace the harness of the generator set.Stop.
Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the genset to identify the circuits.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the component and the ECM from the wiring harness.
At the harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
Use the other multimeter probe to check the resistance across all other contacts in the connector(s) of the ECM and frame ground. Expected Result: The resistance is greater than 5000 ohms for all the measurements.OK - The resistance is greater than 5000 ohms for all of the measurements. The harness circuits are correct.Stop. NOT OK - The resistance is less than 5000 ohms. There is a short in the harness of the generator set. The short is between the suspect wire and the wire with the lowest resistance measurement.Repair: Repair the harness of the generator set or replace the harness of the generator set.Stop.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts valve Caterpillar catalog:
4535250
VALVE GP-WATER
Caterpillar
Caterpillar
4527179
VALVE & LINES GP-LUBRICATION
Caterpillar
Caterpillar
4527178
VALVE GP-LUBE DISTRIBUTION
Caterpillar
Caterpillar
4525415
VALVE-INLET
Caterpillar
Caterpillar
4523400
VALVE & MTG GP-SECONDARY STEER
Caterpillar
Caterpillar
4515886
VALVE GP-CONTROL
Caterpillar
Caterpillar
4621797
VALVE GP-RIDE CONTROL
Caterpillar
Caterpillar
4620422
VALVE GP-CONTROL
Caterpillar
Caterpillar
4610006
VALVE GP-LUBE DISTRIBUTION
Caterpillar
Caterpillar
4609994
VALVE GP-LUBE DISTRIBUTION
Caterpillar
Caterpillar
4587962
VALVE & MTG GP-CONTROL
Caterpillar
Caterpillar
4559799
VALVE GP-MAIN CONTROL
Caterpillar
Caterpillar